Reproducibility of manual and semi-automated late enhancement quantification in patients with Fabry disease. (March 2014)
- Record Type:
- Journal Article
- Title:
- Reproducibility of manual and semi-automated late enhancement quantification in patients with Fabry disease. (March 2014)
- Main Title:
- Reproducibility of manual and semi-automated late enhancement quantification in patients with Fabry disease
- Authors:
- Machann, Wolfram
Geier, Oliver
Koeppe, Sabrina
O'Donnell, Thomas
Greiser, Andreas
Breunig, Frank
Sandstede, Joern
Hahn, Dietbert
Koestler, Herbert
Beer, Meinrad - Abstract:
- Background: Late enhancement (LE) imaging is increasingly used for diagnosis of non-ischemic cardiomyopathy. However, the mostly patchy appearance of LE in this context may reduce the reproducibility of LE measurement. Purpose: To report intra- and inter-observer variabilities of LE measurements in Fabry disease using manual and semi-automated quantification. Material and Methods: Twenty MRI data-sets of male patients aged 44 ± 7 years were analyzed twice (interval 12 months) by one observer and additionally once by a second observer. Left ventricular (LV) parameters were determined using cine MRI. Gradient-echo LE images were analyzed by manual planimetry and by a semi-automatic prototype software. Variabilities were determined by Bland-Altman analyses and additionally intra-class correlation coefficient (ICC) values were calculated to survey intra- and inter-observer reproducibility. Results: The amount of LE was 5.2 ± 5.1 mL or 2.8 ± 2.6 % of LV mass (observer 2). LE was detected predominantly intramurally in a patchy pattern. All patients had LE restricted to the basal infero-lateral parts of the LV. The extent of LE correlated to LV mass (207 ± 70 g, P < 0.05, r = 0.6). The intra- and inter-observer variabilities were −0.6 to 1.0 mL and −0.7 to 1.6 mL, respectively (95% confidence intervals). ICC values were 0.981–0.999. The semi-automatic software allowed quantification of LE areas in all patients. The comparison of LE amount determined by semi-automatic softwareBackground: Late enhancement (LE) imaging is increasingly used for diagnosis of non-ischemic cardiomyopathy. However, the mostly patchy appearance of LE in this context may reduce the reproducibility of LE measurement. Purpose: To report intra- and inter-observer variabilities of LE measurements in Fabry disease using manual and semi-automated quantification. Material and Methods: Twenty MRI data-sets of male patients aged 44 ± 7 years were analyzed twice (interval 12 months) by one observer and additionally once by a second observer. Left ventricular (LV) parameters were determined using cine MRI. Gradient-echo LE images were analyzed by manual planimetry and by a semi-automatic prototype software. Variabilities were determined by Bland-Altman analyses and additionally intra-class correlation coefficient (ICC) values were calculated to survey intra- and inter-observer reproducibility. Results: The amount of LE was 5.2 ± 5.1 mL or 2.8 ± 2.6 % of LV mass (observer 2). LE was detected predominantly intramurally in a patchy pattern. All patients had LE restricted to the basal infero-lateral parts of the LV. The extent of LE correlated to LV mass (207 ± 70 g, P < 0.05, r = 0.6). The intra- and inter-observer variabilities were −0.6 to 1.0 mL and −0.7 to 1.6 mL, respectively (95% confidence intervals). ICC values were 0.981–0.999. The semi-automatic software allowed quantification of LE areas in all patients. The comparison of LE amount determined by semi-automatic software versus manual planimetry yielded an intra-observer variability ranging from −1.9 to 2.3 mL. Conclusion: Semi-automatic planimetry of patchy LE in patients with Fabry disease is feasible. The determined intra- and inter-observer variabilities for manual and semi-automatic planimetry were in the range of 20–40% of LE amount with high ICC values. … (more)
- Is Part Of:
- Acta radiologica. Volume 55:Number 2(2014:Mar.)
- Journal:
- Acta radiologica
- Issue:
- Volume 55:Number 2(2014:Mar.)
- Issue Display:
- Volume 55, Issue 2 (2014)
- Year:
- 2014
- Volume:
- 55
- Issue:
- 2
- Issue Sort Value:
- 2014-0055-0002-0000
- Page Start:
- 155
- Page End:
- 160
- Publication Date:
- 2014-03
- Subjects:
- Cardiomyopathy -- late enhancement -- reproducibility -- quantification
Radiology, Medical -- Periodicals
Radiography, Medical -- Periodicals
Radiotherapy -- Periodicals
616.0757 - Journal URLs:
- http://acr.sagepub.com ↗
http://ar.rsmjournals.com ↗
http://www.uk.sagepub.com/home.nav ↗
http://informahealthcare.com/loi/ard ↗
http://www.tandf.co.uk/journals/titles/02841851.asp ↗ - DOI:
- 10.1177/0284185113505275 ↗
- Languages:
- English
- ISSNs:
- 0284-1851
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0662.000000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5529.xml