Diagnosis of intracranial hemorrhagic lesions: comparison between 3D-SWAN (3D T2*-weighted imaging with multi-echo acquisition) and 2D-T2*-weighted imaging. (March 2014)
- Record Type:
- Journal Article
- Title:
- Diagnosis of intracranial hemorrhagic lesions: comparison between 3D-SWAN (3D T2*-weighted imaging with multi-echo acquisition) and 2D-T2*-weighted imaging. (March 2014)
- Main Title:
- Diagnosis of intracranial hemorrhagic lesions: comparison between 3D-SWAN (3D T2*-weighted imaging with multi-echo acquisition) and 2D-T2*-weighted imaging
- Authors:
- Hayashida, Yoshiko
Kakeda, Shingo
Hiai, Yasuhiro
Ide, Satoshi
Ogasawara, Atsushi
Ooki, Hodaka
Watanabe, Keita
Nishimura, Joji
Ohnari, Norihiro
Korogi, Yukunori - Abstract:
- Background: 3D-susceptibility-weighted angiography (SWAN) can produce high-resolution images that yield excellent susceptibility-weighted contrast at a relatively short acquisition time. Purpose: To compare SWAN- and 2D-T2*-weighted gradient-echo images (T2*-WI) for their sensitivity in the depiction of cerebral hemorrhagic lesions. Material and Methods: We subjected 75 patients with suspected cerebral hemorrhagic lesions to SWAN and T2*-WI at 3T. We first measured the contrast-to-noise ratio (CNR) using an agar phantom that contained different concentrations of superparamagnetic iron oxide (SPIO). The acquisition time for SWAN and T2*-WI was similar (182 vs. 196 s). Neuroradiologists compared the two imaging methods for lesion detectability and conspicuity. Results: The CNR of the phantom was higher on SWAN images. Of the 75 patients, 50 were found to have a total of 278 cerebral hemorrhagic lesions (microbleeds, n = 229 [82.4%]; intracerebral hemorrhage, n = 18 [6.5%]; superficial siderosis, n = 13 [4.7%]; axonal injuries, n = 8 [2.9%]; subarachnoid hemorrhage [SAH] or brain contusion, n = 3 each [1.0%]; subdural hematoma, n = 2 [0.7%]; cavernous hemangioma or dural arterteriovenous fistula, n = 1 each [0.4%]). In none of the lesions was the SWAN sequence inferior to T2*-WI with respect to lesion detectability and conspicuity. In fact, SWAN yielded better lesion conspicuity in patients with superficial siderosis and SAH: it detected significantly more lesions thanBackground: 3D-susceptibility-weighted angiography (SWAN) can produce high-resolution images that yield excellent susceptibility-weighted contrast at a relatively short acquisition time. Purpose: To compare SWAN- and 2D-T2*-weighted gradient-echo images (T2*-WI) for their sensitivity in the depiction of cerebral hemorrhagic lesions. Material and Methods: We subjected 75 patients with suspected cerebral hemorrhagic lesions to SWAN and T2*-WI at 3T. We first measured the contrast-to-noise ratio (CNR) using an agar phantom that contained different concentrations of superparamagnetic iron oxide (SPIO). The acquisition time for SWAN and T2*-WI was similar (182 vs. 196 s). Neuroradiologists compared the two imaging methods for lesion detectability and conspicuity. Results: The CNR of the phantom was higher on SWAN images. Of the 75 patients, 50 were found to have a total of 278 cerebral hemorrhagic lesions (microbleeds, n = 229 [82.4%]; intracerebral hemorrhage, n = 18 [6.5%]; superficial siderosis, n = 13 [4.7%]; axonal injuries, n = 8 [2.9%]; subarachnoid hemorrhage [SAH] or brain contusion, n = 3 each [1.0%]; subdural hematoma, n = 2 [0.7%]; cavernous hemangioma or dural arterteriovenous fistula, n = 1 each [0.4%]). In none of the lesions was the SWAN sequence inferior to T2*-WI with respect to lesion detectability and conspicuity. In fact, SWAN yielded better lesion conspicuity in patients with superficial siderosis and SAH: it detected significantly more lesions than T2*-WI ( P < 0.01) and it was particularly useful for the detection of microbleeds and lesions near the skull base. Conclusion: SWAN is equal or superior to standard T2*-WI for the diagnosis of various cerebral hemorrhagic lesions. Because its acquisition time is reasonable it may replace T2*-WI. … (more)
- Is Part Of:
- Acta radiologica. Volume 55:Number 2(2014:Mar.)
- Journal:
- Acta radiologica
- Issue:
- Volume 55:Number 2(2014:Mar.)
- Issue Display:
- Volume 55, Issue 2 (2014)
- Year:
- 2014
- Volume:
- 55
- Issue:
- 2
- Issue Sort Value:
- 2014-0055-0002-0000
- Page Start:
- 201
- Page End:
- 207
- Publication Date:
- 2014-03
- Subjects:
- CNS -- hemorrhage -- imaging sequences -- MR imaging
Radiology, Medical -- Periodicals
Radiography, Medical -- Periodicals
Radiotherapy -- Periodicals
616.0757 - Journal URLs:
- http://acr.sagepub.com ↗
http://ar.rsmjournals.com ↗
http://www.uk.sagepub.com/home.nav ↗
http://informahealthcare.com/loi/ard ↗
http://www.tandf.co.uk/journals/titles/02841851.asp ↗ - DOI:
- 10.1177/0284185113495836 ↗
- Languages:
- English
- ISSNs:
- 0284-1851
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0662.000000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5529.xml