Sensitivity of a prompt-gamma slit-camera to detect range shifts for proton treatment verification. Issue 3 (December 2017)
- Record Type:
- Journal Article
- Title:
- Sensitivity of a prompt-gamma slit-camera to detect range shifts for proton treatment verification. Issue 3 (December 2017)
- Main Title:
- Sensitivity of a prompt-gamma slit-camera to detect range shifts for proton treatment verification
- Authors:
- Nenoff, Lena
Priegnitz, Marlen
Janssens, Guillaume
Petzoldt, Johannes
Wohlfahrt, Patrick
Trezza, Anna
Smeets, Julien
Pausch, Guntram
Richter, Christian - Abstract:
- Abstract: Background and purpose: A prompt-gamma imaging (PGI) slit-camera was recently applied successfully in clinical proton treatments using pencil beam scanning (PBS) and double scattering (DS). However, its full capability under clinical conditions has still to be systematically evaluated. Here, the performance of the slit-camera is systematically assessed in well-defined error scenarios using realistic treatment deliveries to an anthropomorphic head phantom. Materials and methods: The sensitivity and accuracy to detect introduced global and local range shifts with the slit-camera was investigated in PBS and DS irradiations. For PBS, measured PGI information of shifted geometries were compared spot-wise with un-shifted PGI information derived from either a reference measurement or a treatment-plan-based simulation. Furthermore, for DS and PBS the integral PGI signal of the whole field was evaluated. Results: Deviations from the treatment plan were detected with an accuracy better than 2 mm in PBS. The PGI simulation accuracy was well below 1 mm. Interfractional comparisons are more affected by measurement noise. The field-integral PGI sum signal allows the detection of global shifts in DS. Conclusions: Detection of global and local range shifts under close-to-clinical conditions is possible with the PGI slit-camera. Especially for PBS, high sensitivity and high accuracy in shift detection were found.
- Is Part Of:
- Radiotherapy and oncology. Volume 125:Issue 3(2017:Dec.)
- Journal:
- Radiotherapy and oncology
- Issue:
- Volume 125:Issue 3(2017:Dec.)
- Issue Display:
- Volume 125, Issue 3 (2017)
- Year:
- 2017
- Volume:
- 125
- Issue:
- 3
- Issue Sort Value:
- 2017-0125-0003-0000
- Page Start:
- 534
- Page End:
- 540
- Publication Date:
- 2017-12
- Subjects:
- Range verification -- Prompt-gamma imaging -- Slit camera -- Proton therapy -- PGI
Oncology -- Periodicals
Radiotherapy -- Periodicals
Tumors -- Periodicals
Medical Oncology -- Periodicals
Neoplasms -- radiotherapy -- Periodicals
Radiotherapy -- Periodicals
Radiothérapie -- Périodiques
Cancérologie -- Périodiques
Tumeurs -- Périodiques
Electronic journals
616.9940642 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01678140 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/01678140 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/01678140 ↗
http://www.estro.org/ ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiotherapy-and-oncology/ ↗ - DOI:
- 10.1016/j.radonc.2017.10.013 ↗
- Languages:
- English
- ISSNs:
- 0167-8140
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7240.790000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5491.xml