A preliminary evaluation study of new generation multiplex STR kits comprising of the CODIS core loci and the European Standard Set loci. (November 2017)
- Record Type:
- Journal Article
- Title:
- A preliminary evaluation study of new generation multiplex STR kits comprising of the CODIS core loci and the European Standard Set loci. (November 2017)
- Main Title:
- A preliminary evaluation study of new generation multiplex STR kits comprising of the CODIS core loci and the European Standard Set loci
- Authors:
- Tan, Jolena Ying Ying
Tan, Yuen Peng
Ng, Shilen
Tay, Annabel Suan
Phua, Yong Han
Tan, Wei Jie
Ong, Terenze Yao Rui
Chua, Li Min
Syn, Christopher Kiu Choong - Abstract:
- Abstract: The GlobalFiler™ (Life Technologies), Investigator ® 24plex QS (Qiagen), and PowerPlex ® Fusion 6C (Promega) kits are the latest generation 6-dye fluorescent chemistry STR-PCR amplification kits. These kits allow for the simultaneous amplification of the CODIS core loci and the European Standard Set loci, as well as a few Y-STR loci in addition to the standard sex-determining marker Amelogenin. The present study was designed to be a preliminary evaluation of the three STR-PCR kits in terms of sensitivity, profile recovery from degraded DNA samples, tolerance to PCR inhibitors, and detection of minor components in DNA mixtures. The results showed that the three STR-PCR kits had relatively similar performance with each kit faring better for the different aspects studied. The PowerPlex ® Fusion 6C and the Investigator ® 24plex QS kits were shown to tolerate inhibitors better, while the GlobalFiler™ kit appeared to have a higher mean percentage recovery of alleles from low template DNA samples and for minor components in DNA mixtures. Highlights: GlobalFiler™, Investigator ® 24plex QS and PowerPlex ® Fusion 6C kits were evaluated. Robust amplifications and concordant STR results were obtained by all three kits. Peak height balance was well above 60% at 31 pg DNA template for all three kits. Effects of DNA degradation and PCR inhibition were also well tolerated.
- Is Part Of:
- Journal of forensic and legal medicine. Volume 52(2017)
- Journal:
- Journal of forensic and legal medicine
- Issue:
- Volume 52(2017)
- Issue Display:
- Volume 52, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 52
- Issue:
- 2017
- Issue Sort Value:
- 2017-0052-2017-0000
- Page Start:
- 16
- Page End:
- 23
- Publication Date:
- 2017-11
- Subjects:
- DNA profiling -- GlobalFiler™ -- Investigator® 24plex QS -- PowerPlex® Fusion 6C -- Evaluation study
Medical jurisprudence -- Periodicals
Forensic sciences -- Periodicals
Forensic Medicine -- Periodicals
Médecine légale -- Périodiques
Electronic journals
614.1 - Journal URLs:
- http://www.journals.elsevier.com/journal-of-forensic-and-legal-medicine/ ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/1752928X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jflm.2017.07.017 ↗
- Languages:
- English
- ISSNs:
- 1752-928X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4984.586300
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 5461.xml