Noise reduction angiographic imaging technology reduces radiation dose during bronchial artery embolization. Issue 97 (December 2017)
- Record Type:
- Journal Article
- Title:
- Noise reduction angiographic imaging technology reduces radiation dose during bronchial artery embolization. Issue 97 (December 2017)
- Main Title:
- Noise reduction angiographic imaging technology reduces radiation dose during bronchial artery embolization
- Authors:
- Spink, C.
Avanesov, M.
Schmidt, T.
Grass, M.
Schoen, G.
Adam, G.
Koops, A.
Ittrich, H.
Bannas, P. - Abstract:
- Highlights: Noise reduction imaging technology reduced radiation exposure up to 59%. No significant loss in image quality was observed. Procedure duration and contrast use did not increase significantly. Abstract: Purpose: Comparison of radiation doses in patients undergoing angiographic bronchial artery embolization (BAE) before and after a noise reduction imaging technology upgrade. Methods: We performed a retrospective study of 70 patients undergoing BAE. Procedures were performed before (n = 32) and after (n = 38) the technology upgrade containing additional filters and improved image-processing. Cumulative air kerma (AK), cumulative dose area product (DAP), number of exposure frames, total fluoroscopy time and amount of contrast agent were recorded. Mean values were calculated and compared using two-tailed t -tests. DSA image quality was assessed independently by two blinded readers and compared using the Wilcoxon signed-rank test. Results: Using the new technology resulted in a significant reduction of 59% in DAP (149.2 (103.1–279.1) vs. 54.8 (38.2–100.7) Gy*cm 2, p < 0.001) and a significant reduction of 60% for AK (1.3 (0.6-1.9) vs. 0.5 (0.3-0.9) Gy, p < 0.001) in comparison to procedures before the upgrade. There was no significant difference between the number of exposure frames in both groups (251 ± 181 vs. 254 ± 133 frames, p = 0.07), time of fluoroscopy (28.8 (18.5-50.4) vs. 28.1 (23.3–38.7) min, p = 0.73), or the amount of contrast agent used (139.5 ± 70.8 vs.Highlights: Noise reduction imaging technology reduced radiation exposure up to 59%. No significant loss in image quality was observed. Procedure duration and contrast use did not increase significantly. Abstract: Purpose: Comparison of radiation doses in patients undergoing angiographic bronchial artery embolization (BAE) before and after a noise reduction imaging technology upgrade. Methods: We performed a retrospective study of 70 patients undergoing BAE. Procedures were performed before (n = 32) and after (n = 38) the technology upgrade containing additional filters and improved image-processing. Cumulative air kerma (AK), cumulative dose area product (DAP), number of exposure frames, total fluoroscopy time and amount of contrast agent were recorded. Mean values were calculated and compared using two-tailed t -tests. DSA image quality was assessed independently by two blinded readers and compared using the Wilcoxon signed-rank test. Results: Using the new technology resulted in a significant reduction of 59% in DAP (149.2 (103.1–279.1) vs. 54.8 (38.2–100.7) Gy*cm 2, p < 0.001) and a significant reduction of 60% for AK (1.3 (0.6-1.9) vs. 0.5 (0.3-0.9) Gy, p < 0.001) in comparison to procedures before the upgrade. There was no significant difference between the number of exposure frames in both groups (251 ± 181 vs. 254 ± 133 frames, p = 0.07), time of fluoroscopy (28.8 (18.5-50.4) vs. 28.1 (23.3–38.7) min, p = 0.73), or the amount of contrast agent used (139.5 ± 70.8 vs. 163.1 ± 63.1 ml, p = 0.11). No significant difference regarding image quality could be detected (3 (2, 3) vs. 3 (2–4), p = 0.64). Conclusions: The new angiographic noise reduction technology significantly decreases the radiation dose during bronchial artery embolization without compromising image quality or increasing time of fluoroscopy or contrast volume. … (more)
- Is Part Of:
- European journal of radiology. Issue 97(2017)
- Journal:
- European journal of radiology
- Issue:
- Issue 97(2017)
- Issue Display:
- Volume 97, Issue 97 (2017)
- Year:
- 2017
- Volume:
- 97
- Issue:
- 97
- Issue Sort Value:
- 2017-0097-0097-0000
- Page Start:
- 115
- Page End:
- 118
- Publication Date:
- 2017-12
- Subjects:
- Bronchial artery embolization -- Radiation dosage -- Image-processing technology -- Interventional radiology -- Angiography
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2017.10.029 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5461.xml