Impact of noise-optimized virtual monoenergetic dual-energy computed tomography on image quality in patients with renal cell carcinoma. Issue 97 (December 2017)
- Record Type:
- Journal Article
- Title:
- Impact of noise-optimized virtual monoenergetic dual-energy computed tomography on image quality in patients with renal cell carcinoma. Issue 97 (December 2017)
- Main Title:
- Impact of noise-optimized virtual monoenergetic dual-energy computed tomography on image quality in patients with renal cell carcinoma
- Authors:
- Martin, Simon S.
Wichmann, Julian L.
Pfeifer, Sophia
Leithner, Doris
Lenga, Lukas
Reynolds, Michael A.
D'Angelo, Tommaso
Hammerstingl, Renate
Gruber-Rouh, Tatjana
Vogl, Thomas J.
Albrecht, Moritz H. - Abstract:
- Highlights: DECT enables post-processing of noise-optimized virtual monoenergetic images. VMI+ reconstructions at low-keV levels significantly improve image quality of RCC. Highest CNR and tumor-to-cortex ratios were observed for 40-keV VMI+ series. Highest scores for RCC lesion delineation were assigned for 40-keV VMI+. Abstract: Objective: The aim of this study was to evaluate the impact of a noise-optimized virtual monoenergetic imaging (VMI + ) reconstruction technique on image quality and lesion delineation in patients with renal cell carcinoma (RCC) undergoing abdominal dual-energy computed tomography (DECT). Materials and methods: Fifty-two patients (33 men; 61.5 ± 13.6 years) with RCC underwent contrast-enhanced DECT during the corticomedullary and nephrogenic phase of renal enhancement. DECT datasets were reconstructed with standard linearly-blended (M_0.6), as well as traditional virtual monoenergetic (VMI) and VMI+ algorithms in 10-keV increments from 40 to 100 keV. Contrast-to-noise (CNR) and tumor-to-cortex ratios for corticomedullary- and nephrogenic-phase images were objectively measured by a radiologist with 3 years of experience. Subjective image quality and RCC delineation were evaluated by three independent radiologists. Results: Greatest CNR values were found for 40-keV VMI+ series in both corticomedullary- (8.9 ± 4.9) and nephrogenic-phase (7.1 ± 4.6) images and were significantly higher compared to all other reconstructions ( P < 0.001). Furthermore,Highlights: DECT enables post-processing of noise-optimized virtual monoenergetic images. VMI+ reconstructions at low-keV levels significantly improve image quality of RCC. Highest CNR and tumor-to-cortex ratios were observed for 40-keV VMI+ series. Highest scores for RCC lesion delineation were assigned for 40-keV VMI+. Abstract: Objective: The aim of this study was to evaluate the impact of a noise-optimized virtual monoenergetic imaging (VMI + ) reconstruction technique on image quality and lesion delineation in patients with renal cell carcinoma (RCC) undergoing abdominal dual-energy computed tomography (DECT). Materials and methods: Fifty-two patients (33 men; 61.5 ± 13.6 years) with RCC underwent contrast-enhanced DECT during the corticomedullary and nephrogenic phase of renal enhancement. DECT datasets were reconstructed with standard linearly-blended (M_0.6), as well as traditional virtual monoenergetic (VMI) and VMI+ algorithms in 10-keV increments from 40 to 100 keV. Contrast-to-noise (CNR) and tumor-to-cortex ratios for corticomedullary- and nephrogenic-phase images were objectively measured by a radiologist with 3 years of experience. Subjective image quality and RCC delineation were evaluated by three independent radiologists. Results: Greatest CNR values were found for 40-keV VMI+ series in both corticomedullary- (8.9 ± 4.9) and nephrogenic-phase (7.1 ± 4.6) images and were significantly higher compared to all other reconstructions ( P < 0.001). Furthermore, tumor-to-cortex ratios were highest for 40-keV nephrogenic-phase VMI+ (2.1 ± 3.5; P ≤ 0.016), followed by 50-keV and 60-keV VMI+ (2.0 ± 3.2 and 1.8 ± 2.8, respectively). Qualitative image quality scored highest for 50-keV VMI+ series in corticomedullary-phase reconstructions and 60-keV in nephrogenic-phase reconstructions ( P ≤ 0.031). Highest scores for lesion delineation were assigned for 40-keV VMI+ reconstructions ( P ≤ 0.074). Conclusion: Low-keV VMI+ reconstructions lead to improved image quality and lesion delineation of corticomedullary- and nephrogenic-phase DECT datasets in patients with RCC. … (more)
- Is Part Of:
- European journal of radiology. Issue 97(2017)
- Journal:
- European journal of radiology
- Issue:
- Issue 97(2017)
- Issue Display:
- Volume 97, Issue 97 (2017)
- Year:
- 2017
- Volume:
- 97
- Issue:
- 97
- Issue Sort Value:
- 2017-0097-0097-0000
- Page Start:
- 1
- Page End:
- 7
- Publication Date:
- 2017-12
- Subjects:
- Computed tomography -- Post-processing -- Renal cell carcinoma -- Image quality -- Oncology
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2017.10.008 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5461.xml