Non-contact electric potential measurements of electrode components in an operating polymer electrolyte fuel cell by near ambient pressure XPS. Issue 45 (14th November 2017)
- Record Type:
- Journal Article
- Title:
- Non-contact electric potential measurements of electrode components in an operating polymer electrolyte fuel cell by near ambient pressure XPS. Issue 45 (14th November 2017)
- Main Title:
- Non-contact electric potential measurements of electrode components in an operating polymer electrolyte fuel cell by near ambient pressure XPS
- Authors:
- Yu, Liwei
Takagi, Yasumasa
Nakamura, Takahiro
Sekizawa, Oki
Sakata, Tomohiro
Uruga, Tomoya
Tada, Mizuki
Iwasawa, Yasuhiro
Samjeské, Gabor
Yokoyama, Toshihiko - Abstract:
- Abstract : Electric potentials of electrode components in an operating PEFC were measured without contacting probes by near ambient pressure XPS. Abstract : Photoelectron spectroscopy has the advantage of providing electric potentials by non-contact measurements based on the kinetic energy shift in component potential. We performed operando hard X-ray photoelectron spectroscopy (HAXPES) measurements with an 8 keV excitation source to measure the shift in electron kinetic energies as a function of the voltages of all the components at the anode and cathode electrodes of a polymer electrolyte fuel cell (PEFC). At the cathode electrode, when we increase the voltage between the cathode and anode from 0.2 to 1.2 V, the O 1s and F 1s peaks shift to a lower binding energy and the magnitude of the energy shift is equal to the voltage. The Pt 3d and C 1s peaks do not shift with the voltage since platinum nanoparticles and carbon supports at the cathode electrode have ground contact. In contrast to the cathode electrode, the peak shifts of all the components at the anode electrode show the same amount of shift as the voltages. It is clear that the change in the potential difference occurs only in an electrical double layer at the interface between the cathode electrode (Pt/C) and the electrolyte (Nafion and water), and that the anode electrode is in equilibrium as a pseudo-hydrogen electrode. Moreover, the electric potential variation of the cathode electrode in a PEFC under a powerAbstract : Electric potentials of electrode components in an operating PEFC were measured without contacting probes by near ambient pressure XPS. Abstract : Photoelectron spectroscopy has the advantage of providing electric potentials by non-contact measurements based on the kinetic energy shift in component potential. We performed operando hard X-ray photoelectron spectroscopy (HAXPES) measurements with an 8 keV excitation source to measure the shift in electron kinetic energies as a function of the voltages of all the components at the anode and cathode electrodes of a polymer electrolyte fuel cell (PEFC). At the cathode electrode, when we increase the voltage between the cathode and anode from 0.2 to 1.2 V, the O 1s and F 1s peaks shift to a lower binding energy and the magnitude of the energy shift is equal to the voltage. The Pt 3d and C 1s peaks do not shift with the voltage since platinum nanoparticles and carbon supports at the cathode electrode have ground contact. In contrast to the cathode electrode, the peak shifts of all the components at the anode electrode show the same amount of shift as the voltages. It is clear that the change in the potential difference occurs only in an electrical double layer at the interface between the cathode electrode (Pt/C) and the electrolyte (Nafion and water), and that the anode electrode is in equilibrium as a pseudo-hydrogen electrode. Moreover, the electric potential variation of the cathode electrode in a PEFC under a power generation condition was also directly detected by operando HAXPES. … (more)
- Is Part Of:
- Physical chemistry chemical physics. Volume 19:Issue 45(2017)
- Journal:
- Physical chemistry chemical physics
- Issue:
- Volume 19:Issue 45(2017)
- Issue Display:
- Volume 19, Issue 45 (2017)
- Year:
- 2017
- Volume:
- 19
- Issue:
- 45
- Issue Sort Value:
- 2017-0019-0045-0000
- Page Start:
- 30798
- Page End:
- 30803
- Publication Date:
- 2017-11-14
- Subjects:
- Chemistry, Physical and theoretical -- Periodicals
541.3 - Journal URLs:
- http://pubs.rsc.org/en/journals/journalissues/cp#!issueid=cp016040&type=current&issnprint=1463-9076 ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c7cp05436j ↗
- Languages:
- English
- ISSNs:
- 1463-9076
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.306000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 5445.xml