Comparison of the ecarin chromogenic assay and diluted thrombin time for quantification of dabigatran concentrations. (30th October 2017)
- Record Type:
- Journal Article
- Title:
- Comparison of the ecarin chromogenic assay and diluted thrombin time for quantification of dabigatran concentrations. (30th October 2017)
- Main Title:
- Comparison of the ecarin chromogenic assay and diluted thrombin time for quantification of dabigatran concentrations
- Authors:
- Jaffer, I. H.
Chan, N.
Roberts, R.
Fredenburgh, J. C.
Eikelboom, J. W.
Weitz, J. I. - Abstract:
- Abstract : Essentials Routine monitoring is unnecessary but measuring dabigatran levels is helpful in certain situations. We compared ecarin chromogenic assay (STA‐ECA‐II) and dilute thrombin time (dTT) in patient samples. Both tests provided accurate measurements over a wide range of dabigatran concentrations. Adoption of STA‐ECA‐II and dTT into routine clinical practice will improve patient care. Summary: Background: Although routine coagulation monitoring is unnecessary, measuring plasma dabigatran concentrations can be useful for detecting drug accumulation in renal failure or overdose, assessing the contribution of dabigatran to serious bleeding, planning the timing of urgent surgery or intervention, or determining the suitability for thrombolytic therapy for acute ischemic stroke. Dabigatran concentrations can be quantified using chromogenic or clot‐based tests, such as the ecarin chromogenic assay (ECA) and the diluted thrombin time (dTT), respectively. Objective: The purpose of this study was to compare the results of these assays with dabigatran concentrations measured by the reference standard of mass spectrometry in samples from 50 dabigatran‐treated patients collected at peak and trough after at least 4 months of drug intake. Methods: Drug levels measured with either the STA Ecarin Chromogenic Assay‐II (STA‐ECA‐II) or dTT were linearly correlated with those determined by mass spectrometry over a wide range of concentrations. Results and Conclusions: For detectionAbstract : Essentials Routine monitoring is unnecessary but measuring dabigatran levels is helpful in certain situations. We compared ecarin chromogenic assay (STA‐ECA‐II) and dilute thrombin time (dTT) in patient samples. Both tests provided accurate measurements over a wide range of dabigatran concentrations. Adoption of STA‐ECA‐II and dTT into routine clinical practice will improve patient care. Summary: Background: Although routine coagulation monitoring is unnecessary, measuring plasma dabigatran concentrations can be useful for detecting drug accumulation in renal failure or overdose, assessing the contribution of dabigatran to serious bleeding, planning the timing of urgent surgery or intervention, or determining the suitability for thrombolytic therapy for acute ischemic stroke. Dabigatran concentrations can be quantified using chromogenic or clot‐based tests, such as the ecarin chromogenic assay (ECA) and the diluted thrombin time (dTT), respectively. Objective: The purpose of this study was to compare the results of these assays with dabigatran concentrations measured by the reference standard of mass spectrometry in samples from 50 dabigatran‐treated patients collected at peak and trough after at least 4 months of drug intake. Methods: Drug levels measured with either the STA Ecarin Chromogenic Assay‐II (STA‐ECA‐II) or dTT were linearly correlated with those determined by mass spectrometry over a wide range of concentrations. Results and Conclusions: For detection of levels below 50 ng mL −1 both tests have specificities of at least 96%, suggesting that they accurately detect even low levels of drug. Therefore, regardless of whether a chromogenic or clot‐based platform is preferred, the STA‐ECA‐II and dTT are useful tests for measuring dabigatran concentrations. Unfortunately, neither test is licensed by the United States Food and Drug Administration. Although approved in other jurisdictions, the dTT and STA‐ECA‐II are not widely or rapidly available in most hospitals. Therefore, cooperation between regulators and hospitals is urgently needed to render these tests readily available to inform patient care. … (more)
- Is Part Of:
- Journal of thrombosis and haemostasis. Volume 15:Number 12(2017)
- Journal:
- Journal of thrombosis and haemostasis
- Issue:
- Volume 15:Number 12(2017)
- Issue Display:
- Volume 15, Issue 12 (2017)
- Year:
- 2017
- Volume:
- 15
- Issue:
- 12
- Issue Sort Value:
- 2017-0015-0012-0000
- Page Start:
- 2377
- Page End:
- 2387
- Publication Date:
- 2017-10-30
- Subjects:
- blood coagulation tests -- chromogenic substrates -- dabigatran -- medical laboratory science -- thrombin time
Thrombosis -- Periodicals
Hemostasis -- Periodicals
Blood coagulation disorders -- Periodicals
616.1 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1538-7836 ↗
http://www.blackwellpublishing.com/journals/jth ↗
https://www.sciencedirect.com/journal/journal-of-thrombosis-and-haemostasis ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/jth.13857 ↗
- Languages:
- English
- ISSNs:
- 1538-7933
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5069.345000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 5431.xml