Li, Guoan - Abstract:
- Abstract: Background: The posterolateral (PL) graft experiences a high failure rate in anterior cruciate ligament double‐bundle (DB) reconstruction. It is hypothesized that tunnel positions could dramatically affect the graft forces. Methods: A validated computational model was used to simulate DB reconstruction with various femoral PL tunnel locations (8–11 mm center–center tunnel spacing). Graft fixation was simulated at both 0° and 30°. Knee biomechanics were examined with the knee under a 134 N anterior load and 400 N quadriceps load at 0°, 30°, 60°, and 90° of flexion. Graft forces, tibial translation, and tibial rotation were calculated. Results: PL graft forces at full extension increased with increasing tunnel spacing under both fixation settings, but the knee kinematics was not dramatically affected. Conclusion: Small changes in the femoral PL tunnel position could result in large changes in graft forces, implying that precise PL tunnel position is an important factor in a successful DB reconstruction.
- Is Part Of:
- International journal of medical robotics and computer assisted surgery. Volume 13:Issue 4(2017)
- Journal:
- International journal of medical robotics and computer assisted surgery
- Issue:
- Volume 13:Issue 4(2017)
- Issue Display:
- Volume 13, Issue 4 (2017)
- Year:
- 2017
- Volume:
- 13
- Issue:
- 4
- Issue Sort Value:
- 2017-0013-0004-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2017-06-01
- Subjects:
- ACL -- anatomic double‐bundle ACL reconstruction -- graft failure -- graft forces -- tunnel placement
Robotics in medicine -- Periodicals
Surgery -- Technological innovations -- Periodicals
Imaging systems in medicine -- Periodicals
617.90285 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1478-596X ↗
http://www.roboticpublications.com ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/rcs.1840 ↗
- Languages:
- English
- ISSNs:
- 1478-5951
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.347800
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5431.xml