Fish bone foreign bodies in the pharynx and upper esophagus: evaluation with 64-slice MDCT. (February 2014)
- Record Type:
- Journal Article
- Title:
- Fish bone foreign bodies in the pharynx and upper esophagus: evaluation with 64-slice MDCT. (February 2014)
- Main Title:
- Fish bone foreign bodies in the pharynx and upper esophagus: evaluation with 64-slice MDCT
- Authors:
- Park, Soyeon
Choi, Dae Seob
Shin, Hwa Seon
Cho, Jae Min
Jeon, Kyung Nyeo
Bae, Kyung-Soo
Koh, Eun Ha
Park, Jung Je - Abstract:
- Background: Fish bone (FB) is one of the common causes of foreign body impaction in the pharynx and esophagus. Purpose: To investigate the efficacy of 64-slice multidetector computed tomography (MDCT) for the evaluation of pharynx and upper esophageal FB foreign bodies. Material and Methods: Sixty-six patients with suspected FB foreign body ingestion were examined by plain radiography ( n = 40) and unenhanced MDCT ( n = 66). We analyzed the presence, location, size, shape, and lying position of the foreign bodies. Results: On MDCT, 46 foreign bodies were detected. Among them, 45 were confirmed by endoscopy. The sensitivity of MDCT for the detection of foreign bodies was 100%, which was superior to that of the plain radiography (51.7%). The location of the foreign bodies was most common in the upper esophagus ( n = 22, 47.8%), followed by pharyngoesophageal junction ( n = 10, 21.7%), transjunctional ( n = 7, 15.2%), hypopharynx ( n = 5, 10.9%), and oropharynx ( n = 2, 4.3%). Their longest length was 5.3–40.1 mm (mean, 21.3 mm). Thirty-three FBs (71.7%) were linear and 13 (28.3%) were flat in shape. They showed transverse ( n = 23, 50.0%), parallel ( n = 13, 28.3%), and oblique positions ( n = 10, 21.7%) to the long axis of the pharynx and esophagus, respectively. Conclusion: MDCT is useful for the evaluation of the pharynx and upper esophageal FB foreign bodies.
- Is Part Of:
- Acta radiologica. Volume 55:Number 1(2014:Feb.)
- Journal:
- Acta radiologica
- Issue:
- Volume 55:Number 1(2014:Feb.)
- Issue Display:
- Volume 55, Issue 1 (2014)
- Year:
- 2014
- Volume:
- 55
- Issue:
- 1
- Issue Sort Value:
- 2014-0055-0001-0000
- Page Start:
- 8
- Page End:
- 13
- Publication Date:
- 2014-02
- Subjects:
- Foreign body -- fish bone -- multidetector computed tomography -- pharynx -- esophagus
Radiology, Medical -- Periodicals
Radiography, Medical -- Periodicals
Radiotherapy -- Periodicals
616.0757 - Journal URLs:
- http://acr.sagepub.com ↗
http://ar.rsmjournals.com ↗
http://www.uk.sagepub.com/home.nav ↗
http://informahealthcare.com/loi/ard ↗
http://www.tandf.co.uk/journals/titles/02841851.asp ↗ - DOI:
- 10.1177/0284185113493087 ↗
- Languages:
- English
- ISSNs:
- 0284-1851
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0662.000000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5431.xml