Accuracy of eight deformable image registration (DIR) methods for tomotherapy megavoltage computed tomography (MVCT) images. Issue 4 (29th July 2017)
- Record Type:
- Journal Article
- Title:
- Accuracy of eight deformable image registration (DIR) methods for tomotherapy megavoltage computed tomography (MVCT) images. Issue 4 (29th July 2017)
- Main Title:
- Accuracy of eight deformable image registration (DIR) methods for tomotherapy megavoltage computed tomography (MVCT) images
- Authors:
- Nobnop, Wannapha
Neamin, Hudsaleark
Chitapanarux, Imjai
Wanwilairat, Somsak
Lorvidhaya, Vicharn
Sanghangthum, Taweap - Abstract:
- Abstract: Introduction: The application of deformable image registration (DIR) to megavoltage computed tomography (MVCT) images benefits adaptive radiotherapy. This study aims to quantify the accuracy of DIR for MVCT images when using different deformation methods assessed in a cubic phantom and nasopharyngeal carcinoma (NPC) patients. Methods: In the control studies, the DIR accuracy in air‐tissue and tissue‐tissue interface areas was observed using twelve shapes of acrylic and tissue‐equivalent material inserted in the phantom. In the clinical studies, the 1st and 20th fraction MVCT images of seven NPC patients were used to evaluate application of DIR. The eight DIR methods used in the DIRART software varied in (i) transformation framework (asymmetric or symmetric), (ii) DIR registration algorithm (Demons or Optical Flow) and (iii) mapping direction (forward or backward). The accuracy of the methods was compared using an intensity‐based criterion (correlation coefficient, CC) and volume‐based criterion (Dice's similarity coefficient, DSC). Results: The asymmetric transformation with Optical Flow showed the best performance for air‐tissue interface areas, with a mean CC and DSC of 0.97 ± 0.03 and 0.79 ± 0.11 respectively. The symmetric transformation with Optical Flow showed good agreement for tissue‐tissue interface areas with a CC of (0.99 ± 0.01) and DSC of (0.89 ± 0.03). The sequences of target domains were significantly different in tissue‐tissue interface areas.Abstract: Introduction: The application of deformable image registration (DIR) to megavoltage computed tomography (MVCT) images benefits adaptive radiotherapy. This study aims to quantify the accuracy of DIR for MVCT images when using different deformation methods assessed in a cubic phantom and nasopharyngeal carcinoma (NPC) patients. Methods: In the control studies, the DIR accuracy in air‐tissue and tissue‐tissue interface areas was observed using twelve shapes of acrylic and tissue‐equivalent material inserted in the phantom. In the clinical studies, the 1st and 20th fraction MVCT images of seven NPC patients were used to evaluate application of DIR. The eight DIR methods used in the DIRART software varied in (i) transformation framework (asymmetric or symmetric), (ii) DIR registration algorithm (Demons or Optical Flow) and (iii) mapping direction (forward or backward). The accuracy of the methods was compared using an intensity‐based criterion (correlation coefficient, CC) and volume‐based criterion (Dice's similarity coefficient, DSC). Results: The asymmetric transformation with Optical Flow showed the best performance for air‐tissue interface areas, with a mean CC and DSC of 0.97 ± 0.03 and 0.79 ± 0.11 respectively. The symmetric transformation with Optical Flow showed good agreement for tissue‐tissue interface areas with a CC of (0.99 ± 0.01) and DSC of (0.89 ± 0.03). The sequences of target domains were significantly different in tissue‐tissue interface areas. Conclusions: The deformation method and interface area affected the accuracy of DIR. The validation techniques showed satisfactory volume matching of greater than 0.7 with DSC analysis. The methods can yield acceptable results for clinical applications. Abstract : The different deformation methods and interface areas have affected the accuracy of deformable image registration (DIR). The asymmetric with an Optical Flow showed the best performance for air‐tissue interface areas. However, the symmetric with an Optical Flow showed good agreement for tissue‐tissue interface areas. … (more)
- Is Part Of:
- Journal of medical radiation sciences. Volume 64:Issue 4(2017:Dec.)
- Journal:
- Journal of medical radiation sciences
- Issue:
- Volume 64:Issue 4(2017:Dec.)
- Issue Display:
- Volume 64, Issue 4 (2017)
- Year:
- 2017
- Volume:
- 64
- Issue:
- 4
- Issue Sort Value:
- 2017-0064-0004-0000
- Page Start:
- 290
- Page End:
- 298
- Publication Date:
- 2017-07-29
- Subjects:
- adaptive radiotherapy -- deformable registration -- head and neck -- radiotherapy
Radiology, Medical -- Periodicals
Radiology, Medical -- Australia -- Periodicals
Radiology, Medical -- New Zealand -- Periodicals
Radiotherapy -- Periodicals
Diagnostic imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2051-3909 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmrs.236 ↗
- Languages:
- English
- ISSNs:
- 2051-3895
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5422.xml