Performance of photovoltaic arrays in-vivo and characteristics of prosthetic vision in animals with retinal degeneration. (June 2015)
- Record Type:
- Journal Article
- Title:
- Performance of photovoltaic arrays in-vivo and characteristics of prosthetic vision in animals with retinal degeneration. (June 2015)
- Main Title:
- Performance of photovoltaic arrays in-vivo and characteristics of prosthetic vision in animals with retinal degeneration
- Authors:
- Lorach, Henri
Goetz, Georges
Mandel, Yossi
Lei, Xin
Kamins, Theodore I.
Mathieson, Keith
Huie, Philip
Dalal, Roopa
Harris, James S.
Palanker, Daniel - Abstract:
- Highlights: Photovoltaic anodic subretinal implants can reliably evoke cortical activity in rats. Stimulation thresholds are lowest for 2-diode devices and far below safety limits. Cortical response amplitude can be modulated by pulse duration and intensity. Flicker fusion occurs at stimulation rates above 20 Hz similar to normal vision. State of the electrodes after implantation can be monitored by corneal recordings. Abstract: Loss of photoreceptors during retinal degeneration leads to blindness, but information can be reintroduced into the visual system using electrical stimulation of the remaining retinal neurons. Subretinal photovoltaic arrays convert pulsed illumination into pulsed electric current to stimulate the inner retinal neurons. Since required irradiance exceeds the natural luminance levels, an invisible near-infrared (915 nm) light is used to avoid photophobic effects. We characterized the thresholds and dynamic range of cortical responses to prosthetic stimulation with arrays of various pixel sizes and with different number of photodiodes. Stimulation thresholds for devices with 140 μm pixels were approximately half those of 70 μm pixels, and with both pixel sizes, thresholds were lower with 2 diodes than with 3 diodes per pixel. In all cases these thresholds were more than two orders of magnitude below the ocular safety limit. At high stimulation frequencies (>20 Hz), the cortical response exhibited flicker fusion. Over one order of magnitude of dynamicHighlights: Photovoltaic anodic subretinal implants can reliably evoke cortical activity in rats. Stimulation thresholds are lowest for 2-diode devices and far below safety limits. Cortical response amplitude can be modulated by pulse duration and intensity. Flicker fusion occurs at stimulation rates above 20 Hz similar to normal vision. State of the electrodes after implantation can be monitored by corneal recordings. Abstract: Loss of photoreceptors during retinal degeneration leads to blindness, but information can be reintroduced into the visual system using electrical stimulation of the remaining retinal neurons. Subretinal photovoltaic arrays convert pulsed illumination into pulsed electric current to stimulate the inner retinal neurons. Since required irradiance exceeds the natural luminance levels, an invisible near-infrared (915 nm) light is used to avoid photophobic effects. We characterized the thresholds and dynamic range of cortical responses to prosthetic stimulation with arrays of various pixel sizes and with different number of photodiodes. Stimulation thresholds for devices with 140 μm pixels were approximately half those of 70 μm pixels, and with both pixel sizes, thresholds were lower with 2 diodes than with 3 diodes per pixel. In all cases these thresholds were more than two orders of magnitude below the ocular safety limit. At high stimulation frequencies (>20 Hz), the cortical response exhibited flicker fusion. Over one order of magnitude of dynamic range could be achieved by varying either pulse duration or irradiance. However, contrast sensitivity was very limited. Cortical responses could be detected even with only a few illuminated pixels. Finally, we demonstrate that recording of the corneal electric potential in response to patterned illumination of the subretinal arrays allows monitoring the current produced by each pixel, and thereby assessing the changes in the implant performance over time. … (more)
- Is Part Of:
- Vision research. Volume 111(2015)Part B
- Journal:
- Vision research
- Issue:
- Volume 111(2015)Part B
- Issue Display:
- Volume 111, Issue 2015 (2015)
- Year:
- 2015
- Volume:
- 111
- Issue:
- 2015
- Issue Sort Value:
- 2015-0111-2015-0000
- Page Start:
- 142
- Page End:
- 148
- Publication Date:
- 2015-06
- Subjects:
- VEP visually evoked potential -- RCS Royal College Surgeon -- LE Long Evans -- NIR near infrared -- SEM Standard error of the mean
Prosthetic vision -- Subretinal implant -- Visually evoked potentials -- Rat
Vision -- Periodicals
573.88 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00426989 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.visres.2014.09.007 ↗
- Languages:
- English
- ISSNs:
- 0042-6989
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9240.925000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5425.xml