A novel microfluidic microelectrode chip for a significantly enhanced monitoring of NPY-receptor activation in live mode. Issue 24 (9th November 2017)
- Record Type:
- Journal Article
- Title:
- A novel microfluidic microelectrode chip for a significantly enhanced monitoring of NPY-receptor activation in live mode. Issue 24 (9th November 2017)
- Main Title:
- A novel microfluidic microelectrode chip for a significantly enhanced monitoring of NPY-receptor activation in live mode
- Authors:
- Zitzmann, Franziska D.
Jahnke, Heinz-Georg
Nitschke, Felix
Beck-Sickinger, Annette G.
Abel, Bernd
Belder, Detlev
Robitzki, Andrea A. - Abstract:
- Abstract : We present a FEM simulation based step-by-step development of a microelectrode array integrated into a microfluidic chip for the non-invasive real-time monitoring of living cells. Abstract : Lab-on-a-chip devices that combine, e.g. chemical synthesis with integrated on-chip analytics and multi-compartment organ-on-a-chip approaches, are a fast and attractive evolving research area. While integration of appropriate cell models in microfluidic setups for monitoring the biological activity of synthesis products or test compounds is already in focus, the integration of label-free bioelectronic analysis techniques is still poorly realized. In this context, we investigated the capabilities of impedance spectroscopy as a non-destructive real-time monitoring technique for adherent cell models in a microfluidic setup. While an initial adaptation of a microelectrode array (MEA) layout from a static setup revealed clear restrictions in the application of impedance spectroscopy in a microfluidic chip, we could demonstrate the advantage of a FEM simulation based rational MEA layout optimization for an optimum electrical field distribution within microfluidic structures. Furthermore, FEM simulation based analysis of shear stress and time-dependent test compound distribution led to identification of an optimal flow rate. Based on the simulation derived optimized microfluidic MEA, comparable impedance spectra characteristics were achieved for HEK293A cells cultured underAbstract : We present a FEM simulation based step-by-step development of a microelectrode array integrated into a microfluidic chip for the non-invasive real-time monitoring of living cells. Abstract : Lab-on-a-chip devices that combine, e.g. chemical synthesis with integrated on-chip analytics and multi-compartment organ-on-a-chip approaches, are a fast and attractive evolving research area. While integration of appropriate cell models in microfluidic setups for monitoring the biological activity of synthesis products or test compounds is already in focus, the integration of label-free bioelectronic analysis techniques is still poorly realized. In this context, we investigated the capabilities of impedance spectroscopy as a non-destructive real-time monitoring technique for adherent cell models in a microfluidic setup. While an initial adaptation of a microelectrode array (MEA) layout from a static setup revealed clear restrictions in the application of impedance spectroscopy in a microfluidic chip, we could demonstrate the advantage of a FEM simulation based rational MEA layout optimization for an optimum electrical field distribution within microfluidic structures. Furthermore, FEM simulation based analysis of shear stress and time-dependent test compound distribution led to identification of an optimal flow rate. Based on the simulation derived optimized microfluidic MEA, comparable impedance spectra characteristics were achieved for HEK293A cells cultured under microfluidic and static conditions. Furthermore, HEK293A cells expressing Y1 receptors were used to successfully demonstrate the capabilities of impedimetric monitoring of cellular alterations in the microfluidic setup. More strikingly, the maximum impedimetric signal for the receptor activation was significantly increased by a factor of 2.8. Detailed investigations of cell morphology and motility led to the conclusion that cultivation under microfluidic conditions could lead to an extended and stabilized cell–electrode interface. … (more)
- Is Part Of:
- Lab on a chip. Volume 17:Issue 24(2017)
- Journal:
- Lab on a chip
- Issue:
- Volume 17:Issue 24(2017)
- Issue Display:
- Volume 17, Issue 24 (2017)
- Year:
- 2017
- Volume:
- 17
- Issue:
- 24
- Issue Sort Value:
- 2017-0017-0024-0000
- Page Start:
- 4294
- Page End:
- 4302
- Publication Date:
- 2017-11-09
- Subjects:
- Miniature electronic equipment -- Periodicals
Combinatorial chemistry -- Periodicals
Biotechnology -- Periodicals
543.0813 - Journal URLs:
- http://pubs.rsc.org/en/journals/journalissues/lc#!recentarticles&adv ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c7lc00754j ↗
- Languages:
- English
- ISSNs:
- 1473-0197
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5137.730000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File: