A new method for the determination of cadmium at ultratrace levels using slotted quartz tube-flame atomic absorption spectrometry after preconcentration with stearic acid coated magnetite nanoparticles. Issue 12 (15th November 2017)
- Record Type:
- Journal Article
- Title:
- A new method for the determination of cadmium at ultratrace levels using slotted quartz tube-flame atomic absorption spectrometry after preconcentration with stearic acid coated magnetite nanoparticles. Issue 12 (15th November 2017)
- Main Title:
- A new method for the determination of cadmium at ultratrace levels using slotted quartz tube-flame atomic absorption spectrometry after preconcentration with stearic acid coated magnetite nanoparticles
- Authors:
- Akkaya, Erhan
Aylin Kasa, Nursu
Çetin, Gülten
Bakirdere, Sezgin - Abstract:
- Abstract : A combination of slotted quartz tube attached flame atomic absorption spectrometry (SQT-FAAS) and stearic acid coated magnetite nanoparticle based solid phase microextraction (SPME-MNP) was used for the determination of ultratrace amounts of cadmium. Abstract : A combination of slotted quartz tube attached flame atomic absorption spectrometry (SQT-FAAS) and stearic acid coated magnetite nanoparticle based solid phase microextraction (SPME-MNP) was used for the determination of ultratrace amounts of cadmium. Coated magnetite nanoparticles were used for the extraction of cadmium from aqueous samples by providing a large surface area with the help of their surfactant properties. The separation of the extracted cadmium from the aqueous phase was facilitated by the application of an external magnetic field. Several experimental variables such as the mixing type, duration of mixing, pH of buffer solution and amount of eluent were optimized in order to enhance the extraction efficiency for cadmium. Under the optimum experimental and instrumental conditions, 0.11 μg L −1 limit of detection (LOD) and 0.36 μg L −1 limit of quantification (LOQ) were obtained. Recovery tests were carried out to investigate the effect of a sample matrix on the developed method and the percent recoveries obtained were between 97 and 105% for spiked lake water and urine samples. A standard reference material of tomato leaves (NIST 1573a) was also analysed to validate the accuracy of theAbstract : A combination of slotted quartz tube attached flame atomic absorption spectrometry (SQT-FAAS) and stearic acid coated magnetite nanoparticle based solid phase microextraction (SPME-MNP) was used for the determination of ultratrace amounts of cadmium. Abstract : A combination of slotted quartz tube attached flame atomic absorption spectrometry (SQT-FAAS) and stearic acid coated magnetite nanoparticle based solid phase microextraction (SPME-MNP) was used for the determination of ultratrace amounts of cadmium. Coated magnetite nanoparticles were used for the extraction of cadmium from aqueous samples by providing a large surface area with the help of their surfactant properties. The separation of the extracted cadmium from the aqueous phase was facilitated by the application of an external magnetic field. Several experimental variables such as the mixing type, duration of mixing, pH of buffer solution and amount of eluent were optimized in order to enhance the extraction efficiency for cadmium. Under the optimum experimental and instrumental conditions, 0.11 μg L −1 limit of detection (LOD) and 0.36 μg L −1 limit of quantification (LOQ) were obtained. Recovery tests were carried out to investigate the effect of a sample matrix on the developed method and the percent recoveries obtained were between 97 and 105% for spiked lake water and urine samples. A standard reference material of tomato leaves (NIST 1573a) was also analysed to validate the accuracy of the developed method and the experimental result agreed with the certified value. Low percent relative standard deviation values also indicated high precision. … (more)
- Is Part Of:
- Journal of analytical atomic spectrometry. Volume 32:Issue 12(2017)
- Journal:
- Journal of analytical atomic spectrometry
- Issue:
- Volume 32:Issue 12(2017)
- Issue Display:
- Volume 32, Issue 12 (2017)
- Year:
- 2017
- Volume:
- 32
- Issue:
- 12
- Issue Sort Value:
- 2017-0032-0012-0000
- Page Start:
- 2433
- Page End:
- 2438
- Publication Date:
- 2017-11-15
- Subjects:
- Atomic spectra -- Periodicals
Atomic absorption spectroscopy -- Periodicals
543.0858 - Journal URLs:
- http://pubs.rsc.org/en/journals/journalissues/ja#!recentarticles&adv ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c7ja00303j ↗
- Languages:
- English
- ISSNs:
- 0267-9477
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4928.200000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 5420.xml