A high-accuracy screening method of 44 cephalosporins in meat using liquid chromatography quadrupole-orbitrap hybrid mass spectrometry. Issue 46 (13th November 2017)
- Record Type:
- Journal Article
- Title:
- A high-accuracy screening method of 44 cephalosporins in meat using liquid chromatography quadrupole-orbitrap hybrid mass spectrometry. Issue 46 (13th November 2017)
- Main Title:
- A high-accuracy screening method of 44 cephalosporins in meat using liquid chromatography quadrupole-orbitrap hybrid mass spectrometry
- Authors:
- Hong, Yun-He
Xu, Xiu-Li
Li, Wei-Qing
Xu, Bo-Zhou
Wu, Han-Qiu
Cheng, Yan
Chen, Hong
Zhang, Bao-Shan
Zhang, Feng - Abstract:
- Abstract : In this study, we report the development of a screening method for highly accurate and sensitive analysis of 44 cephalosporins in 4 representative meats (pork, beef, chicken, and mutton). Abstract : In this study, we report the development of a screening method for highly accurate and sensitive analysis of 44 cephalosporins in 4 representative meats (pork, beef, chicken, and mutton). The approach is based on liquid chromatography quadrupole-orbitrap hybrid high resolution mass spectrometry (LC-Q-Orbitrap, HRMS). Highly accurate identification markers of cephalosporins were obtained to have a tool for the detection of non-target or even unknown cephalosporins. Optimal chromatographic separation was studied, and Ascentis C8 column was chosen after comparing several different column materials and mobile phases. A simple sample treatment method consisting of extraction with a mixture of acetonitrile and water followed by solid-phase extraction (SPE) with a PRiME HLB cartridge was developed. The methodology was validated in accordance with the Commission Decision 2002/657/EC by evaluating the following required parameters: linearity, accuracy, repeatability, decision limit (CCα), and detection capability (CCβ). For the matrices studied herein, the recovery rates ranged from 69.2% to 129.0% with the inter- and intra-day variability under 15%. The CCα and CCβ were determined according to maximum residue limit (MRL) or minimum required performance limit (MRPL) whenAbstract : In this study, we report the development of a screening method for highly accurate and sensitive analysis of 44 cephalosporins in 4 representative meats (pork, beef, chicken, and mutton). Abstract : In this study, we report the development of a screening method for highly accurate and sensitive analysis of 44 cephalosporins in 4 representative meats (pork, beef, chicken, and mutton). The approach is based on liquid chromatography quadrupole-orbitrap hybrid high resolution mass spectrometry (LC-Q-Orbitrap, HRMS). Highly accurate identification markers of cephalosporins were obtained to have a tool for the detection of non-target or even unknown cephalosporins. Optimal chromatographic separation was studied, and Ascentis C8 column was chosen after comparing several different column materials and mobile phases. A simple sample treatment method consisting of extraction with a mixture of acetonitrile and water followed by solid-phase extraction (SPE) with a PRiME HLB cartridge was developed. The methodology was validated in accordance with the Commission Decision 2002/657/EC by evaluating the following required parameters: linearity, accuracy, repeatability, decision limit (CCα), and detection capability (CCβ). For the matrices studied herein, the recovery rates ranged from 69.2% to 129.0% with the inter- and intra-day variability under 15%. The CCα and CCβ were determined according to maximum residue limit (MRL) or minimum required performance limit (MRPL) when established. The method has been successfully applied to meat samples purchased from the local market, and ceftazidime, which has not yet been considered in the current legislation all over the world, has been found in one of these samples. … (more)
- Is Part Of:
- Analytical methods. Volume 9:Issue 46(2017)
- Journal:
- Analytical methods
- Issue:
- Volume 9:Issue 46(2017)
- Issue Display:
- Volume 9, Issue 46 (2017)
- Year:
- 2017
- Volume:
- 9
- Issue:
- 46
- Issue Sort Value:
- 2017-0009-0046-0000
- Page Start:
- 6534
- Page End:
- 6548
- Publication Date:
- 2017-11-13
- Subjects:
- Chemistry, Analytic -- Periodicals
Analytical biochemistry -- Periodicals
Chemical laboratories -- Standards -- Periodicals
543.1905 - Journal URLs:
- http://pubs.rsc.org/en/Journals/JournalIssues/AY ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c7ay01903c ↗
- Languages:
- English
- ISSNs:
- 1759-9660
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0897.103700
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 5417.xml