Stereotactic vacuum-assisted breast biopsy: Comparison between 11- and 8-gauge needles. Issue 12 (December 2017)
- Record Type:
- Journal Article
- Title:
- Stereotactic vacuum-assisted breast biopsy: Comparison between 11- and 8-gauge needles. Issue 12 (December 2017)
- Main Title:
- Stereotactic vacuum-assisted breast biopsy: Comparison between 11- and 8-gauge needles
- Authors:
- Ruggirello, Irene
Nori, Jacopo
Desideri, Isacco
Saieva, Calogero
Giannotti, Elisabetta
Bicchierai, Giulia
De Benedetto, Diego
Francolini, Giulio
Bianchi, Simonetta
Vezzosi, Vania
Sanchez, Luis
Susini, Tommaso
Orzalesi, Lorenzo
Meattini, Icro
Livi, Lorenzo
Miele, Vittorio - Abstract:
- Abstract: Purpose: The 11-gauge (11G) stereotactic vacuum-assisted breast biopsy (VABB) showed a better profile than 14G-VABB in terms of feasibility, safety, microcalcification sampling, and accuracy. Underestimation rates were significantly lower with 11G-VABB than with 14G-VABB. Thus, the introduction of an even larger needle at the VABB procedure could reduce this rate further. The purpose of this study was to compare the overall performance of stereotactic VABB with 8G and 11G needles. Materials and methods: Four hundred and three VABBs performed between July 2012 and February 2015 at the Breast Diagnostic Unit of Careggi Hospital in Florence were retrospectively analyzed; 197 were performed with 11G-VABB and 206 with 8G-VABB. Lesions were classified according to mammographical patterns in microcalcifications, architectural distortions, or opacities, and all biopsy targets were classified according to BIRADS classification as BIRADS III, IV or V. Data were collected on radiological classification of targets, imaging presentation, procedure time, number of specimens per procedure, and microcalcification retrieval on histological findings. Surgery was always performed when high-risk or malignant lesions (B3 or B5) were detected; the final diagnosis was made on surgical pathology. Results: Compared to VABB with an 11G needle, 8G-VABB allows a reduction in the time needed to complete the procedure (20.6 versus 27.4, P < 0.00001) and the number of specimens collected perAbstract: Purpose: The 11-gauge (11G) stereotactic vacuum-assisted breast biopsy (VABB) showed a better profile than 14G-VABB in terms of feasibility, safety, microcalcification sampling, and accuracy. Underestimation rates were significantly lower with 11G-VABB than with 14G-VABB. Thus, the introduction of an even larger needle at the VABB procedure could reduce this rate further. The purpose of this study was to compare the overall performance of stereotactic VABB with 8G and 11G needles. Materials and methods: Four hundred and three VABBs performed between July 2012 and February 2015 at the Breast Diagnostic Unit of Careggi Hospital in Florence were retrospectively analyzed; 197 were performed with 11G-VABB and 206 with 8G-VABB. Lesions were classified according to mammographical patterns in microcalcifications, architectural distortions, or opacities, and all biopsy targets were classified according to BIRADS classification as BIRADS III, IV or V. Data were collected on radiological classification of targets, imaging presentation, procedure time, number of specimens per procedure, and microcalcification retrieval on histological findings. Surgery was always performed when high-risk or malignant lesions (B3 or B5) were detected; the final diagnosis was made on surgical pathology. Results: Compared to VABB with an 11G needle, 8G-VABB allows a reduction in the time needed to complete the procedure (20.6 versus 27.4, P < 0.00001) and the number of specimens collected per lesion (21.6 versus 12.2, P < 0.00001). Moreover, 8G-VABB resulted in the same diagnostic accuracy, and the underestimation rates were comparable between the two groups for both B3 and DCIS lesions. Conclusions: The 8G needle should be considered as a valid alternative option in VABB for breast lesions. … (more)
- Is Part Of:
- European journal of surgical oncology. Volume 43:Issue 12(2017:Dec.)
- Journal:
- European journal of surgical oncology
- Issue:
- Volume 43:Issue 12(2017:Dec.)
- Issue Display:
- Volume 43, Issue 12 (2017)
- Year:
- 2017
- Volume:
- 43
- Issue:
- 12
- Issue Sort Value:
- 2017-0043-0012-0000
- Page Start:
- 2257
- Page End:
- 2260
- Publication Date:
- 2017-12
- Subjects:
- Biopsy -- Breast -- 8G versus 11G needle -- Comparison
Oncology -- Periodicals
Cancer -- Surgery -- Periodicals
Medical Oncology -- Periodicals
Neoplasms -- surgery -- Periodicals
Cancer -- Chirurgie -- Périodiques
Cancérologie -- Périodiques
Oncologie
Chirurgie (geneeskunde)
Electronic journals
Electronic journals -- Sciences
Electronic journals -- Medicine
Electronic journals
616.994059005 - Journal URLs:
- http://www.ejso.com/ ↗
http://www.sciencedirect.com/science/journal/07487983 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/07487983 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0748-7983;screen=info;ECOIP ↗
http://www.elsevier.com/journals ↗
http://www.harcourt-international.com/journals ↗
http://www.idealibrary.com/cgi-bin/links/toc/ejso ↗ - DOI:
- 10.1016/j.ejso.2017.07.011 ↗
- Languages:
- English
- ISSNs:
- 0748-7983
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.745500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 5398.xml