Waste heat recovery optimization in micro gas turbine applications using advanced humidified gas turbine cycle concepts. (1st December 2017)
- Record Type:
- Journal Article
- Title:
- Waste heat recovery optimization in micro gas turbine applications using advanced humidified gas turbine cycle concepts. (1st December 2017)
- Main Title:
- Waste heat recovery optimization in micro gas turbine applications using advanced humidified gas turbine cycle concepts
- Authors:
- De Paepe, Ward
Montero Carrero, Marina
Bram, Svend
Contino, Francesco
Parente, Alessandro - Abstract:
- Highlights: Water injection in micro gas turbine (mGT) cycles has a large potential for waste heat recovery. Current humidified mGT cycles do not fully exploit the potential for waste heat recovery. Different cycle concepts of large scale gas turbines are applied on the small scale mGT to find the optimal cycle. The cycle concept allowing the highest water injection rate and lowest stack temperature recovers most waste heat. The REVAP cycle concept with preheat was identified as the optimal cycle. Abstract: Introduction of water in a micro Gas Turbine (mGT) has proven to be a very effective method to recover waste heat into the cycle, since it increases the mGT electrical efficiency significantly. Different routes exist for water introduction in the mGT cycle. Classical routes, like injection of steam/preheated water or the micro Humid Air Turbine (mHAT) concept, where water is introduced in the cycle by means of a saturation tower, have shown to have high potential. However none of the previously mentioned cycles exploits the full thermodynamic potential for waste heat recovery through water introduction. More advanced humidified Gas Turbine (GT) cycles have been proposed and studied for large scale GTs. So far, none of these concepts have been applied on mGT scale, despite their high potential. In this paper, we study the impact of these different, more advanced, humidified GT cycle concepts on the mGT performance. The different selected cycles – next to the classicalHighlights: Water injection in micro gas turbine (mGT) cycles has a large potential for waste heat recovery. Current humidified mGT cycles do not fully exploit the potential for waste heat recovery. Different cycle concepts of large scale gas turbines are applied on the small scale mGT to find the optimal cycle. The cycle concept allowing the highest water injection rate and lowest stack temperature recovers most waste heat. The REVAP cycle concept with preheat was identified as the optimal cycle. Abstract: Introduction of water in a micro Gas Turbine (mGT) has proven to be a very effective method to recover waste heat into the cycle, since it increases the mGT electrical efficiency significantly. Different routes exist for water introduction in the mGT cycle. Classical routes, like injection of steam/preheated water or the micro Humid Air Turbine (mHAT) concept, where water is introduced in the cycle by means of a saturation tower, have shown to have high potential. However none of the previously mentioned cycles exploits the full thermodynamic potential for waste heat recovery through water introduction. More advanced humidified Gas Turbine (GT) cycles have been proposed and studied for large scale GTs. So far, none of these concepts have been applied on mGT scale, despite their high potential. In this paper, we study the impact of these different, more advanced, humidified GT cycle concepts on the mGT performance. The different selected cycles – next to the classical steam injection or injection of (preheated) liquid water in the recuperated cycle and the mHAT – were: micro Humid Air Turbine Plus (mHAT+), Advanced Humid Air Turbine (AHAT) and the REgenerative EVAPoration (REVAP®) cycle concept. The impact of these concepts on the mGT cycle performance has been studied on the Turbec T100 mGT. Simulations indicated that humidifying the air of the mGT has a significant beneficial effect on cycle performance due to the increased waste heat recovery, resulting in a higher electrical power output (at constant rotational speed) or reduced fuel consumption (at constant power output), both leading to an increased electrical efficiency. Depending on the different cycle layout used, more or less waste heat could be recovered from the exhaust gas. The REVAP® concept with feedwater preheat was identified as the optimal cycle layout within the selected options. By applying this concept to the Turbec T100, most waste heat could be recovered, achieving the highest electrical efficiency increase. … (more)
- Is Part Of:
- Applied energy. Volume 207(2017)
- Journal:
- Applied energy
- Issue:
- Volume 207(2017)
- Issue Display:
- Volume 207, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 207
- Issue:
- 2017
- Issue Sort Value:
- 2017-0207-2017-0000
- Page Start:
- 218
- Page End:
- 229
- Publication Date:
- 2017-12-01
- Subjects:
- micro Gas Turbine (mGT) -- Cycle humidification -- Waste heat recovery -- micro Humid Air Turbine (mHAT) -- Advanced Humid Air Turbine (AHAT) -- REgenerative EVAPoration (REVAP)
Power (Mechanics) -- Periodicals
Energy conservation -- Periodicals
Energy conversion -- Periodicals
621.042 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03062619 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.apenergy.2017.06.001 ↗
- Languages:
- English
- ISSNs:
- 0306-2619
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1572.300000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File: