The influence of inertial sensor sampling frequency on the accuracy of measurement parameters in rearfoot running. Issue 14 (26th October 2017)
- Record Type:
- Journal Article
- Title:
- The influence of inertial sensor sampling frequency on the accuracy of measurement parameters in rearfoot running. Issue 14 (26th October 2017)
- Main Title:
- The influence of inertial sensor sampling frequency on the accuracy of measurement parameters in rearfoot running
- Authors:
- Mitschke, Christian
Zaumseil, Falk
Milani, Thomas L. - Abstract:
- Abstract: Increasingly, inertial sensors are being used for running analyses. The aim of this study was to systematically investigate the influence of inertial sensor sampling frequencies (SF) on the accuracy of kinematic, spatio-temporal, and kinetic parameters. We hypothesized that running analyses at lower SF result in less signal information and therefore the inability to sufficiently interpret measurement data. Twenty-one subjects participated in this study. Rearfoot strikers ran on an indoor running track at a velocity of 3.5 ± 0.1 ms −1 . A uniaxial accelerometer was attached at the tibia and an inertial measurement unit was mounted at the heel of the right shoe. All sensors were synchronized at the start and data was measured with 1000 Hz (reference SF). Datasets were reduced to 500, 333, 250, 200, and 100 Hz in post-processing. The results of this study showed that a minimum SF of 500 Hz should be used to accurately measure kinetic parameters (e.g. peak heel acceleration). In contrast, stride length showed accurate results even at 333 Hz. 200 Hz were required to calculate parameters accurately for peak tibial acceleration, stride duration, and all kinematic measurements. The information from this study is necessary to correctly interpret measurement data of existing investigations and to plan future studies.
- Is Part Of:
- Computer methods in biomechanics and biomedical engineering. Volume 20:Issue 14(2017)
- Journal:
- Computer methods in biomechanics and biomedical engineering
- Issue:
- Volume 20:Issue 14(2017)
- Issue Display:
- Volume 20, Issue 14 (2017)
- Year:
- 2017
- Volume:
- 20
- Issue:
- 14
- Issue Sort Value:
- 2017-0020-0014-0000
- Page Start:
- 1502
- Page End:
- 1511
- Publication Date:
- 2017-10-26
- Subjects:
- Inertial measurement units -- inertial sensor -- sampling frequency -- rearfoot running -- acceleration -- angular velocity
Biomechanics -- Data processing -- Periodicals
Biomedical engineering -- Periodicals
Biomechanics -- Periodicals
Biomedical Engineering -- methods -- Periodicals
Computing Methodologies -- Periodicals
612.7 - Journal URLs:
- http://www.tandfonline.com/toc/gcmb20/current ↗
http://www.tandfonline.com/ ↗ - DOI:
- 10.1080/10255842.2017.1382482 ↗
- Languages:
- English
- ISSNs:
- 1025-5842
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3394.100250
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 5390.xml