Sequential proton boost after standard chemoradiation for high-grade glioma. Issue 2 (November 2017)
- Record Type:
- Journal Article
- Title:
- Sequential proton boost after standard chemoradiation for high-grade glioma. Issue 2 (November 2017)
- Main Title:
- Sequential proton boost after standard chemoradiation for high-grade glioma
- Authors:
- Adeberg, Sebastian
Bernhardt, Denise
Harrabi, Semi Ben
Uhl, Matthias
Paul, Angela
Bougatf, Nina
Verma, Vivek
Unterberg, Andreas
Wick, Wolfgang
Haberer, Thomas
Combs, Stephanie E.
Herfarth, Klaus
Debus, Juergen
Rieken, Stefan - Abstract:
- Abstract: Purpose: To retrospectively assess the feasibility and safety of a sequential proton boost following conventional chemoradiation in high-grade glioma (HGG). Method and materials: Sixty-six consecutive patients with HGG were treated with 50.0 Gy photons (50.0–50.4 Gy) in 2.0 Gy (1.8–2.0 Gy) fractions, followed by a proton boost with 10 Gy equivalent (Gy(RBE)) in 2.0 Gy(RBE) fractions. Patients were matched one to one with 66 patients with HGG undergoing conventional radiation therapy (RT) with 60.0 Gy photons (59.4–60.0 Gy) in 2.0 Gy fractions (1.8–2.0 Gy). Matching criteria were age, WHO grade, Karnofsky's performance status, PTV size, temozolomide therapy (each p > 0.1). The study assessed progression-free survival (PFS), overall survival (OS), acute treatment-related toxicity (CTCAE v.4.03) and pseudoprogression (RANO criteria). Results: Median PFS and OS were similar in both treatment groups (bimodality RT, PFS: 8.8 months [2–32 months], OS 19.1 months [4–41 months]; photon-only RT, PFS: 7.2 months [2–39 months], 20.9 months [3–53 months]; p = 0.430 and p = 0.125). The median PTV of the proton boost was significantly smaller than the photon plan PTVs (each p < 0.001). Acute toxicity was mild. Toxicity ≥grade 2 was observed in 6 patients (9%) receiving bimodality RT and 9 patients (14%) receiving photon-only RT. Two types of severe adverse events (CTCAE grade 3) occurred solely in the photon-only group: severe increase in intracranial pressure (5%); andAbstract: Purpose: To retrospectively assess the feasibility and safety of a sequential proton boost following conventional chemoradiation in high-grade glioma (HGG). Method and materials: Sixty-six consecutive patients with HGG were treated with 50.0 Gy photons (50.0–50.4 Gy) in 2.0 Gy (1.8–2.0 Gy) fractions, followed by a proton boost with 10 Gy equivalent (Gy(RBE)) in 2.0 Gy(RBE) fractions. Patients were matched one to one with 66 patients with HGG undergoing conventional radiation therapy (RT) with 60.0 Gy photons (59.4–60.0 Gy) in 2.0 Gy fractions (1.8–2.0 Gy). Matching criteria were age, WHO grade, Karnofsky's performance status, PTV size, temozolomide therapy (each p > 0.1). The study assessed progression-free survival (PFS), overall survival (OS), acute treatment-related toxicity (CTCAE v.4.03) and pseudoprogression (RANO criteria). Results: Median PFS and OS were similar in both treatment groups (bimodality RT, PFS: 8.8 months [2–32 months], OS 19.1 months [4–41 months]; photon-only RT, PFS: 7.2 months [2–39 months], 20.9 months [3–53 months]; p = 0.430 and p = 0.125). The median PTV of the proton boost was significantly smaller than the photon plan PTVs (each p < 0.001). Acute toxicity was mild. Toxicity ≥grade 2 was observed in 6 patients (9%) receiving bimodality RT and 9 patients (14%) receiving photon-only RT. Two types of severe adverse events (CTCAE grade 3) occurred solely in the photon-only group: severe increase in intracranial pressure (5%); and generalized seizures (3%). Pseudoprogression was rare, occurring on average 6 weeks after radiotherapy, and was balanced in both treatment groups ( n = 4 each; 8%). Conclusion: Delivering a proton boost to significantly smaller target volumes when compared to photon-only plans, yielded comparable progression and survival rates at lower CTCAE grade 3 acute toxicity rates. Pseudoprogression occurred rarely and evenly distributed in both treatment groups. Thus, bimodality RT was at least equivalent regarding outcome and potentially superior with respect to toxicity in patients with HGG. Summary: Treating patients with HGG with 50.0 Gy photons in 2.0 Gy fractions, followed by a proton boost with 10 Gy(RBE) in 2.0 Gy(RBE) fractions, is safe and feasible. Severe radiation-induced acute toxicity and pseudoprogression were rare in both treatment groups. Therefore, in this clinical setting, combined proton radiotherapy might be beneficial in terms of further risk reduction for treatment-related side effects. Interestingly, treatment volume reduction using a proton boost led to comparable survival and progression rates with decreased severe treatment-related toxicity compared to conventional photon radiotherapy. … (more)
- Is Part Of:
- Radiotherapy and oncology. Volume 125:Issue 2(2017:Nov.)
- Journal:
- Radiotherapy and oncology
- Issue:
- Volume 125:Issue 2(2017:Nov.)
- Issue Display:
- Volume 125, Issue 2 (2017)
- Year:
- 2017
- Volume:
- 125
- Issue:
- 2
- Issue Sort Value:
- 2017-0125-0002-0000
- Page Start:
- 266
- Page End:
- 272
- Publication Date:
- 2017-11
- Subjects:
- Brain tumors -- Proton boost -- RBE -- Toxicity -- Pseudoprogression -- Particle therapy
Oncology -- Periodicals
Radiotherapy -- Periodicals
Tumors -- Periodicals
Medical Oncology -- Periodicals
Neoplasms -- radiotherapy -- Periodicals
Radiotherapy -- Periodicals
Radiothérapie -- Périodiques
Cancérologie -- Périodiques
Tumeurs -- Périodiques
Electronic journals
616.9940642 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01678140 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/01678140 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/01678140 ↗
http://www.estro.org/ ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiotherapy-and-oncology/ ↗ - DOI:
- 10.1016/j.radonc.2017.09.040 ↗
- Languages:
- English
- ISSNs:
- 0167-8140
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7240.790000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5477.xml