Validation of noninvasive blood pressure equipment: which peripheral artery is best for comparison studies in dogs?. (September 2017)
- Record Type:
- Journal Article
- Title:
- Validation of noninvasive blood pressure equipment: which peripheral artery is best for comparison studies in dogs?. (September 2017)
- Main Title:
- Validation of noninvasive blood pressure equipment: which peripheral artery is best for comparison studies in dogs?
- Authors:
- da Cunha, Anderson F.
Ramos, Sara J.
Domingues, Michelle
Shelby, Amanda
Beaufrère, Hugues
Stout, Rhett
Acierno, Mark J. - Abstract:
- Abstract: Objectives: 1) To determine which peripheral artery commonly used for invasive arterial blood pressure (IBP) monitoring yields the least bias when compared with noninvasive blood pressure (NIBP) values obtained at the antebrachium of the dog, and 2) to identify and describe differences in systolic (SAP), mean (MAP) and diastolic arterial pressures (DAP) among different anatomical locations. Study design: Prospective experimental study. Animals: Twenty adult hound dogs weighing 24.5 ± 1.1 kg (mean ± standard deviation). Methods: Four peripheral arteries—dorsal pedal, median caudal, intermediate auricular and superficial palmar arteries—were catheterized with 20 gauge, 3.8 cm catheters. One NIBP cuff was placed in the middle third of the antebrachium. Four sets of IBP and NIBP measurements were simultaneously collected every 2 minutes. A linear mixed model was performed to analyze the collected data. Results: IBP values varied depending on the arterial catheterization site. The difference was greater for SAP. NIBP measured at the antebrachium had the best agreement with IBP measured at the median caudal artery. Conclusion and clinical relevance: IBP varies among anatomical locations. The smallest bias and narrowest limits of agreement were obtained at the median caudal artery, providing the best overall agreement with the equipment studied. The median caudal artery may be the preferable anatomical location for clinical comparison studies between IBP and NIBP in dogsAbstract: Objectives: 1) To determine which peripheral artery commonly used for invasive arterial blood pressure (IBP) monitoring yields the least bias when compared with noninvasive blood pressure (NIBP) values obtained at the antebrachium of the dog, and 2) to identify and describe differences in systolic (SAP), mean (MAP) and diastolic arterial pressures (DAP) among different anatomical locations. Study design: Prospective experimental study. Animals: Twenty adult hound dogs weighing 24.5 ± 1.1 kg (mean ± standard deviation). Methods: Four peripheral arteries—dorsal pedal, median caudal, intermediate auricular and superficial palmar arteries—were catheterized with 20 gauge, 3.8 cm catheters. One NIBP cuff was placed in the middle third of the antebrachium. Four sets of IBP and NIBP measurements were simultaneously collected every 2 minutes. A linear mixed model was performed to analyze the collected data. Results: IBP values varied depending on the arterial catheterization site. The difference was greater for SAP. NIBP measured at the antebrachium had the best agreement with IBP measured at the median caudal artery. Conclusion and clinical relevance: IBP varies among anatomical locations. The smallest bias and narrowest limits of agreement were obtained at the median caudal artery, providing the best overall agreement with the equipment studied. The median caudal artery may be the preferable anatomical location for clinical comparison studies between IBP and NIBP in dogs when the cuff is on the antebrachium. … (more)
- Is Part Of:
- Veterinary anaesthesia and analgesia. Volume 44:Number 5(2017)
- Journal:
- Veterinary anaesthesia and analgesia
- Issue:
- Volume 44:Number 5(2017)
- Issue Display:
- Volume 44, Issue 5 (2017)
- Year:
- 2017
- Volume:
- 44
- Issue:
- 5
- Issue Sort Value:
- 2017-0044-0005-0000
- Page Start:
- 1068
- Page End:
- 1075
- Publication Date:
- 2017-09
- Subjects:
- blood pressure -- comparison -- direct -- IBP -- indirect -- NIBP
Veterinary anesthesia -- Periodicals
636.089 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1467-2995 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1016/j.vaa.2017.07.002 ↗
- Languages:
- English
- ISSNs:
- 1467-2987
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9226.528500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5484.xml