Prediction of time-integrated activity coefficients in PRRT using simulated dynamic PET and a pharmacokinetic model. (October 2017)
- Record Type:
- Journal Article
- Title:
- Prediction of time-integrated activity coefficients in PRRT using simulated dynamic PET and a pharmacokinetic model. (October 2017)
- Main Title:
- Prediction of time-integrated activity coefficients in PRRT using simulated dynamic PET and a pharmacokinetic model
- Authors:
- Hardiansyah, Deni
Attarwala, Ali Asgar
Kletting, Peter
Mottaghy, Felix M.
Glatting, Gerhard - Abstract:
- Highlights: Individual treatment planning for PRRT using PET and a PBPK model is investigated. Dynamic 68 Ga-DOTATATE PET data are used to predict the therapy with 90 Y-DOTATATE. This may lead to simplified individual treatment planning in molecular radiotherapy. Abstract: Purpose: To investigate the accuracy of predicted time-integrated activity coefficients (TIACs) in peptide-receptor radionuclide therapy (PRRT) using simulated dynamic PET data and a physiologically based pharmacokinetic (PBPK) model. Methods: PBPK parameters were estimated using biokinetic data of 15 patients after injection of (152 ± 15) MBq of 111 In-DTPAOC (total peptide amount (5.78 ± 0.25) nmol). True mathematical phantoms of patients (MPPs) were the PBPK model with the estimated parameters. Dynamic PET measurements were simulated as being done after bolus injection of 150 MBq 68 Ga-DOTATATE using the true MPPs. Dynamic PET scans around 35 min p.i. (P1 ), 4 h p.i. (P2 ) and the combination of P1 and P2 (P3 ) were simulated. Each measurement was simulated with four frames of 5 min each and 2 bed positions. PBPK parameters were fitted to the PET data to derive the PET-predicted MPPs. Therapy was simulated assuming an infusion of 5.1 GBq of 90 Y-DOTATATE over 30 min in both true and PET-predicted MPPs. TIACs of simulated therapy were calculated, true MPPs (true TIACs) and predicted MPPs (predicted TIACs) followed by the calculation of variabilities v . Results: For P1 and P2 the population variabilitiesHighlights: Individual treatment planning for PRRT using PET and a PBPK model is investigated. Dynamic 68 Ga-DOTATATE PET data are used to predict the therapy with 90 Y-DOTATATE. This may lead to simplified individual treatment planning in molecular radiotherapy. Abstract: Purpose: To investigate the accuracy of predicted time-integrated activity coefficients (TIACs) in peptide-receptor radionuclide therapy (PRRT) using simulated dynamic PET data and a physiologically based pharmacokinetic (PBPK) model. Methods: PBPK parameters were estimated using biokinetic data of 15 patients after injection of (152 ± 15) MBq of 111 In-DTPAOC (total peptide amount (5.78 ± 0.25) nmol). True mathematical phantoms of patients (MPPs) were the PBPK model with the estimated parameters. Dynamic PET measurements were simulated as being done after bolus injection of 150 MBq 68 Ga-DOTATATE using the true MPPs. Dynamic PET scans around 35 min p.i. (P1 ), 4 h p.i. (P2 ) and the combination of P1 and P2 (P3 ) were simulated. Each measurement was simulated with four frames of 5 min each and 2 bed positions. PBPK parameters were fitted to the PET data to derive the PET-predicted MPPs. Therapy was simulated assuming an infusion of 5.1 GBq of 90 Y-DOTATATE over 30 min in both true and PET-predicted MPPs. TIACs of simulated therapy were calculated, true MPPs (true TIACs) and predicted MPPs (predicted TIACs) followed by the calculation of variabilities v . Results: For P1 and P2 the population variabilities of kidneys, liver and spleen were acceptable ( v < 10%). For the tumours and the remainders, the values were large (up to 25%). For P3, population variabilities for all organs including the remainder further improved, except that of the tumour ( v > 10%). Conclusion: Treatment planning of PRRT based on dynamic PET data seems possible for the kidneys, liver and spleen using a PBPK model and patient specific information. … (more)
- Is Part Of:
- Physica medica. Volume 42(2017)
- Journal:
- Physica medica
- Issue:
- Volume 42(2017)
- Issue Display:
- Volume 42, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 42
- Issue:
- 2017
- Issue Sort Value:
- 2017-0042-2017-0000
- Page Start:
- 298
- Page End:
- 304
- Publication Date:
- 2017-10
- Subjects:
- PBPK model -- PRRT treatment planning -- Dynamic PET -- PET noise model
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2017.06.024 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5405.xml