Impact of deformable image registration accuracy on thoracic images with different regularization weight parameter settings. (October 2017)
- Record Type:
- Journal Article
- Title:
- Impact of deformable image registration accuracy on thoracic images with different regularization weight parameter settings. (October 2017)
- Main Title:
- Impact of deformable image registration accuracy on thoracic images with different regularization weight parameter settings
- Authors:
- Miura, Hideharu
Ozawa, Shuichi
Nakao, Minoru
Furukawa, Kengo
Doi, Yoshiko
Kawabata, Hideo
Kenjou, Masahiro
Nagata, Yasushi - Abstract:
- Highlights: An investigation on improvement of DIR accuracy using a script is presented. The regularization weight has an influence on the DIR accuracy in the thoracic. A high regularization weight could be helpful in improving DIR accuracy. Abstract: Purpose: We assessed the deformable image registration (DIR) accuracy of thoracic images under different regularization weights using commercially available DIR software. Methods: The thoracic 4-dimensional (4D) CT images of 10 patients were used. The datasets for these patients were provided by DIR-lab (www.dir-lab.com ) and included a coordinate list of 300 anatomic landmarks that had been manually identified. The ANAtomically CONstrained Deformation Algorithm (ANACONDA) of RayStation (RaySearch Laboratories, Stockholm, Sweden) was used to deform the peak-inhale to peak-exhale images under different regularization weights (4, 40, 400-default setting, 1500, 4000, 10, 000, 15, 000, 20, 000, 30, 000, and 40, 000). The regularization weights were changed using a script. The registration error (RE) was determined by calculating the difference at each landmark point between the displacement calculated by the DIR software and that calculated by the landmark. We measured the computation time for each regularization weight setting. Results: High regularization weights resulted in a smaller RE than that observed with lower regularization weights. The RE decreases rapidly with increase in regularization weight before reaching a plateau.Highlights: An investigation on improvement of DIR accuracy using a script is presented. The regularization weight has an influence on the DIR accuracy in the thoracic. A high regularization weight could be helpful in improving DIR accuracy. Abstract: Purpose: We assessed the deformable image registration (DIR) accuracy of thoracic images under different regularization weights using commercially available DIR software. Methods: The thoracic 4-dimensional (4D) CT images of 10 patients were used. The datasets for these patients were provided by DIR-lab (www.dir-lab.com ) and included a coordinate list of 300 anatomic landmarks that had been manually identified. The ANAtomically CONstrained Deformation Algorithm (ANACONDA) of RayStation (RaySearch Laboratories, Stockholm, Sweden) was used to deform the peak-inhale to peak-exhale images under different regularization weights (4, 40, 400-default setting, 1500, 4000, 10, 000, 15, 000, 20, 000, 30, 000, and 40, 000). The regularization weights were changed using a script. The registration error (RE) was determined by calculating the difference at each landmark point between the displacement calculated by the DIR software and that calculated by the landmark. We measured the computation time for each regularization weight setting. Results: High regularization weights resulted in a smaller RE than that observed with lower regularization weights. The RE decreases rapidly with increase in regularization weight before reaching a plateau. No significant difference was found between a regularization weight of 400 and regularization weights of 4, 40, 4000 or 40, 000 (P value >0.05). The range of the average time was 8.4–12.2 s. Conclusions: We concluded that the default setting for ANACONDA is stable with respect to regularization weight in the thoracic region. … (more)
- Is Part Of:
- Physica medica. Volume 42(2017)
- Journal:
- Physica medica
- Issue:
- Volume 42(2017)
- Issue Display:
- Volume 42, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 42
- Issue:
- 2017
- Issue Sort Value:
- 2017-0042-2017-0000
- Page Start:
- 108
- Page End:
- 111
- Publication Date:
- 2017-10
- Subjects:
- Deformable image registration -- Regularization weight -- 4D CT -- Lung
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2017.09.122 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5405.xml