Concomitant screening for liver fibrosis and steatosis in French type 2 diabetic patients using Fibroscan. (2nd July 2017)
- Record Type:
- Journal Article
- Title:
- Concomitant screening for liver fibrosis and steatosis in French type 2 diabetic patients using Fibroscan. (2nd July 2017)
- Main Title:
- Concomitant screening for liver fibrosis and steatosis in French type 2 diabetic patients using Fibroscan
- Authors:
- Roulot, Dominique
Roudot‐Thoraval, Françoise
NKontchou, Gisele
Kouacou, Narcisse
Costes, Jean‐Luc
Elourimi, Ghassan
Le Clesiau, Hervé
Ziol, Marianne
Beaugrand, Michel - Abstract:
- Abstract: Background: Type 2 diabetes is a risk factor for steatohepatitis and fibrosis. Non‐invasive liver stiffness (LS) and controlled attenuation parameter (CAP) measurements by Fibroscan allow assessing liver fat and fibrosis. Aim: To determine the prevalence of steatosis and significant fibrosis in a community‐based diabetic population. Methods: LS and CAP were measured in 705 patients using the standard "M probe." A second "XL probe" was used, without CAP measurement, in case of failure with the "M probe." Results: LS and CAP measurements were obtained in 437 patients (the M group), LS measurements (LSM) with the XL probe being available in additional 232 patients. After the combined use of both probes, LSM failure and unreliable result were 1.6% and 5.6% respectively. Overall, 12.7% (n=85), 7.3% and 2.1% exhibited significant or advanced fibrosis or cirrhosis (LSM≥8 kPa, ≥9.6 kPa, ≥13 kPa respectively), half of the patients with LSM≥8 kPa displayed normal liver tests. Significant and severe steatosis were measured in 75% and 24% of the M group patients. By multivariate analysis, factors associated with severe fibrosis were age, overweight, high GGT. Forty‐seven patients with LSM≥8 kPa underwent liver biopsy; 93% had steatosis and 51% severe fibrosis. A significant correlation was found between LSM values and fibrosis score with an accuracy rate of 83%, 68% and 83% for LSM≥8 kPa, ≥9.6 kPa and ≥13 kPa respectively. Conclusions: The prevalence of significant steatosisAbstract: Background: Type 2 diabetes is a risk factor for steatohepatitis and fibrosis. Non‐invasive liver stiffness (LS) and controlled attenuation parameter (CAP) measurements by Fibroscan allow assessing liver fat and fibrosis. Aim: To determine the prevalence of steatosis and significant fibrosis in a community‐based diabetic population. Methods: LS and CAP were measured in 705 patients using the standard "M probe." A second "XL probe" was used, without CAP measurement, in case of failure with the "M probe." Results: LS and CAP measurements were obtained in 437 patients (the M group), LS measurements (LSM) with the XL probe being available in additional 232 patients. After the combined use of both probes, LSM failure and unreliable result were 1.6% and 5.6% respectively. Overall, 12.7% (n=85), 7.3% and 2.1% exhibited significant or advanced fibrosis or cirrhosis (LSM≥8 kPa, ≥9.6 kPa, ≥13 kPa respectively), half of the patients with LSM≥8 kPa displayed normal liver tests. Significant and severe steatosis were measured in 75% and 24% of the M group patients. By multivariate analysis, factors associated with severe fibrosis were age, overweight, high GGT. Forty‐seven patients with LSM≥8 kPa underwent liver biopsy; 93% had steatosis and 51% severe fibrosis. A significant correlation was found between LSM values and fibrosis score with an accuracy rate of 83%, 68% and 83% for LSM≥8 kPa, ≥9.6 kPa and ≥13 kPa respectively. Conclusions: The prevalence of significant steatosis is very high and significant fibrosis affect 12.7% of the patients. Fibroscan is an effective procedure to screen for fibrosis and steatosis in diabetic patients. … (more)
- Is Part Of:
- Liver international. Volume 37:Number 12(2017)
- Journal:
- Liver international
- Issue:
- Volume 37:Number 12(2017)
- Issue Display:
- Volume 37, Issue 12 (2017)
- Year:
- 2017
- Volume:
- 37
- Issue:
- 12
- Issue Sort Value:
- 2017-0037-0012-0000
- Page Start:
- 1897
- Page End:
- 1906
- Publication Date:
- 2017-07-02
- Subjects:
- controlled attenuation parameter -- Fibroscan -- liver stiffness -- screening -- type 2 diabetes
Liver -- Periodicals
Liver -- Diseases -- Periodicals
616.362 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1478-3231 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/liv.13481 ↗
- Languages:
- English
- ISSNs:
- 1478-3223
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5280.514000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 5464.xml