Clinical performance of high‐resolution late gadolinium enhancement imaging with compressed sensing. Issue 6 (16th March 2017)
- Record Type:
- Journal Article
- Title:
- Clinical performance of high‐resolution late gadolinium enhancement imaging with compressed sensing. Issue 6 (16th March 2017)
- Main Title:
- Clinical performance of high‐resolution late gadolinium enhancement imaging with compressed sensing
- Authors:
- Basha, Tamer A.
Akçakaya, Mehmet
Liew, Charlene
Tsao, Connie W.
Delling, Francesca N.
Addae, Gifty
Ngo, Long
Manning, Warren J.
Nezafat, Reza - Abstract:
- Abstract : Purpose: To evaluate diagnostic image quality of 3D late gadolinium enhancement (LGE) with high isotropic spatial resolution (∼1.4 mm 3 ) images reconstructed from randomly undersampled k ‐space using LOw‐dimensional‐structure Self‐learning and Thresholding (LOST). Materials and Methods: We prospectively enrolled 270 patients (181 men; 55 ± 14 years) referred for myocardial viability assessment. 3D LGE with isotropic spatial resolution of 1.4 ± 0.1 mm 3 was acquired at 1.5T using a LOST acceleration rate of 3 to 5. In a subset of 121 patients, 3D LGE or phase‐sensitive LGE were acquired with parallel imaging with an acceleration rate of 2 for comparison. Two readers evaluated image quality using a scale of 1 (poor) to 4 (excellent) and assessed for scar presence. The McNemar test statistic was used to compare the proportion of detected scar between the two sequences. We assessed the association between image quality and characteristics (age, gender, torso dimension, weight, heart rate), using generalized linear models. Results: Overall, LGE detection proportions for 3D LGE with LOST were similar between readers 1 and 2 (16.30% vs. 18.15%). For image quality, readers gave 85.9% and 80.0%, respectively, for images categorized as good or excellent. Overall proportion of scar presence was not statistically different from conventional 3D LGE (28% vs. 33% [ P = 0.17] for reader 1 and 26% vs. 31% [ P = 0.37] for reader 2). Increasing subject heart rate was associatedAbstract : Purpose: To evaluate diagnostic image quality of 3D late gadolinium enhancement (LGE) with high isotropic spatial resolution (∼1.4 mm 3 ) images reconstructed from randomly undersampled k ‐space using LOw‐dimensional‐structure Self‐learning and Thresholding (LOST). Materials and Methods: We prospectively enrolled 270 patients (181 men; 55 ± 14 years) referred for myocardial viability assessment. 3D LGE with isotropic spatial resolution of 1.4 ± 0.1 mm 3 was acquired at 1.5T using a LOST acceleration rate of 3 to 5. In a subset of 121 patients, 3D LGE or phase‐sensitive LGE were acquired with parallel imaging with an acceleration rate of 2 for comparison. Two readers evaluated image quality using a scale of 1 (poor) to 4 (excellent) and assessed for scar presence. The McNemar test statistic was used to compare the proportion of detected scar between the two sequences. We assessed the association between image quality and characteristics (age, gender, torso dimension, weight, heart rate), using generalized linear models. Results: Overall, LGE detection proportions for 3D LGE with LOST were similar between readers 1 and 2 (16.30% vs. 18.15%). For image quality, readers gave 85.9% and 80.0%, respectively, for images categorized as good or excellent. Overall proportion of scar presence was not statistically different from conventional 3D LGE (28% vs. 33% [ P = 0.17] for reader 1 and 26% vs. 31% [ P = 0.37] for reader 2). Increasing subject heart rate was associated with lower image quality (estimated slope = –0.009 ( P = 0.001)). Conclusion: High‐resolution 3D LGE with LOST yields good to excellent image quality in >80% of patients and identifies patients with LV scar at the same rate as conventional 3D LGE. Level of Evidence: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2017;46:1829–1838. … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 46:Issue 6(2017)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 46:Issue 6(2017)
- Issue Display:
- Volume 46, Issue 6 (2017)
- Year:
- 2017
- Volume:
- 46
- Issue:
- 6
- Issue Sort Value:
- 2017-0046-0006-0000
- Page Start:
- 1829
- Page End:
- 1838
- Publication Date:
- 2017-03-16
- Subjects:
- compressed sensing -- late gadolinium enhancement -- myocardial viability
Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.25695 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5362.xml