Reference intervals for absolute and percentage immature platelet fraction using the Sysmex XN-10 automated haematology analyser in a UK population. (17th November 2017)
- Record Type:
- Journal Article
- Title:
- Reference intervals for absolute and percentage immature platelet fraction using the Sysmex XN-10 automated haematology analyser in a UK population. (17th November 2017)
- Main Title:
- Reference intervals for absolute and percentage immature platelet fraction using the Sysmex XN-10 automated haematology analyser in a UK population
- Authors:
- Ali, Usman
Knight, Gavin
Gibbs, Roz
Tsitsikas, Dimitris A. - Abstract:
- Abstract: Background: Immature platelet fraction (IPF) estimation is a non-invasive and sensitive test that is available on recently introduced Sysmex XN-series of automated haematology analysers. It is a direct cellular indicator of thrombopoiesis. The aim of this study was to establish reference intervals for IPF, for both absolute (A-IPF) and percentage (%-IPF) measurements. Material and methods: A total of 2366 samples that met the inclusion criteria were assayed for full blood count on the Sysmex XN-10 and a non-parametric percentile method was used for calculating the reference intervals. Results: After the outliers were excluded, the reference interval for %-IPF and A-IPF on Sysmex XN-10 were 1.6–10.1% and 4.37–23.21 × 10 9 /L in total individuals, respectively. There was a statistical significance noted between the sexes ( p = .004) for %-IPF, therefore a sex-specific reference interval was established, which was 1.8–10.0% for the males and 1.5–10.1% for females. No significant difference in sex status for A-IPF and age status for both %-IPF and A-IPF was observed. A very poor correlation was estimated between age versus %-IPF, ρ = 0.0156, and age versus A-IPF, ρ = −0.0023, indicating that there is no overall biological relationship between age and these parameters. As expected, a strong correlation between %-IPF and A-IPF was noted which could be attributed to their inter-relatedness. Conclusions: This large-scale study showed comparable reference intervals withAbstract: Background: Immature platelet fraction (IPF) estimation is a non-invasive and sensitive test that is available on recently introduced Sysmex XN-series of automated haematology analysers. It is a direct cellular indicator of thrombopoiesis. The aim of this study was to establish reference intervals for IPF, for both absolute (A-IPF) and percentage (%-IPF) measurements. Material and methods: A total of 2366 samples that met the inclusion criteria were assayed for full blood count on the Sysmex XN-10 and a non-parametric percentile method was used for calculating the reference intervals. Results: After the outliers were excluded, the reference interval for %-IPF and A-IPF on Sysmex XN-10 were 1.6–10.1% and 4.37–23.21 × 10 9 /L in total individuals, respectively. There was a statistical significance noted between the sexes ( p = .004) for %-IPF, therefore a sex-specific reference interval was established, which was 1.8–10.0% for the males and 1.5–10.1% for females. No significant difference in sex status for A-IPF and age status for both %-IPF and A-IPF was observed. A very poor correlation was estimated between age versus %-IPF, ρ = 0.0156, and age versus A-IPF, ρ = −0.0023, indicating that there is no overall biological relationship between age and these parameters. As expected, a strong correlation between %-IPF and A-IPF was noted which could be attributed to their inter-relatedness. Conclusions: This large-scale study showed comparable reference intervals with the previous studies for %-IPF and A-IPF in a UK population. It found the need to establish sex-specific reference intervals for %-IPF, but not for A-IPF, whereas reference intervals were found to be stable across the age range. … (more)
- Is Part Of:
- Scandinavian journal of clinical & laboratory investigation. Volume 77:Number 8(2017)
- Journal:
- Scandinavian journal of clinical & laboratory investigation
- Issue:
- Volume 77:Number 8(2017)
- Issue Display:
- Volume 77, Issue 8 (2017)
- Year:
- 2017
- Volume:
- 77
- Issue:
- 8
- Issue Sort Value:
- 2017-0077-0008-0000
- Page Start:
- 658
- Page End:
- 664
- Publication Date:
- 2017-11-17
- Subjects:
- Reference values -- blood platelet -- haematology -- thrombocytopenia -- blood cell count -- haematologic tests -- haematologic diseases -- clinical laboratory techniques -- clinical laboratory services -- UK
Clinical biochemistry -- Periodicals
Physiology, Pathological -- Periodicals
Physiology, Experimental -- Periodicals
Medicine -- Research -- Periodicals
Clinical medicine -- Periodicals
616.0072 - Journal URLs:
- http://informahealthcare.com/loi/clb ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/00365513.2017.1394488 ↗
- Languages:
- English
- ISSNs:
- 0036-5513
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8087.500000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5364.xml