Single-Operator Ultrasound-Guided Central Venous Catheter Insertion Verifies Proper Tip Placement*. Issue 10 (October 2017)
- Record Type:
- Journal Article
- Title:
- Single-Operator Ultrasound-Guided Central Venous Catheter Insertion Verifies Proper Tip Placement*. Issue 10 (October 2017)
- Main Title:
- Single-Operator Ultrasound-Guided Central Venous Catheter Insertion Verifies Proper Tip Placement*
- Authors:
- Galante, Ori
Slutsky, Tzachi
Fuchs, Lior
Smoliakov, Alexander
Mizrakli, Yuval
Novack, Victor
Brotfein, Evgeni
Klein, Moti
Frenkel, Amit
Koifman, Leonid
Almog, Yaniv - Abstract:
- Abstract : Objectives: To evaluate whether a single-operator ultrasound-guided, right-sided, central venous catheter insertion verifies proper placement and shortens time to catheter utilization. Design: Prospective observational study with historical controls. Setting: Adult ICUs. Patients: Sixty-four consecutive patients undergoing ultrasound-assisted right-sided central venous catheterization compared with 92 serial historic controls who had unassisted central catheter insertion at the same sites. Interventions: Subcostal transthoracic echocardiography during catheter insertion. Measurements and Main Results: The primary outcome was the correct placement of the catheter tip determined by postprocedural chest radiography. The subclavian site was used in 41 patients (64%) (inserted without ultrasound guidance) in the ultrasound-assisted group and 62 (67%) in the control group, whereas the jugular vein was used in the remaining patients. The tip was accurately positioned in 59 of 68 patients (86.7%) in the ultrasound-assisted group compared with 51 of 94 (54.8%) in the control group ( p < 0.001). The median time from end of the procedure to catheter utilization after chest radiography approval was 2.4 hours. Conclusions: A single-operator ultrasound-guided central venous catheter insertion is effective in verifying proper tip placement and shortens time to catheter utilization.
- Is Part Of:
- Critical care medicine. Volume 45:Issue 10(2017)
- Journal:
- Critical care medicine
- Issue:
- Volume 45:Issue 10(2017)
- Issue Display:
- Volume 45, Issue 10 (2017)
- Year:
- 2017
- Volume:
- 45
- Issue:
- 10
- Issue Sort Value:
- 2017-0045-0010-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-10
- Subjects:
- central venous catheter -- misplacement -- ultrasound
Critical care medicine -- Periodicals
Soins intensifs -- Périodiques
616.028 - Journal URLs:
- http://journals.lww.com/ccmjournal/Pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/CCM.0000000000002500 ↗
- Languages:
- English
- ISSNs:
- 0090-3493
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3487.451000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 5367.xml