Wide Disagreement Between Alternative Assessments of Premorbid Physical Activity: Subjective Patient and Surrogate Reports and Objective Smartphone Data. Issue 10 (October 2017)
- Record Type:
- Journal Article
- Title:
- Wide Disagreement Between Alternative Assessments of Premorbid Physical Activity: Subjective Patient and Surrogate Reports and Objective Smartphone Data. Issue 10 (October 2017)
- Main Title:
- Wide Disagreement Between Alternative Assessments of Premorbid Physical Activity
- Authors:
- Gluck, Samuel
Summers, Matthew J.
Goddard, Thomas P.
Andrawos, Alice
Smith, Natalie C.
Lange, Kylie
Iwashyna, Theodore J.
Deane, Adam M. - Abstract:
- Abstract : Objectives: Surrogate-decision maker and patient self-reported estimates of the distances walked prior to acute illness are subjective and may be imprecise. It may be possible to extract objective data from a patient's smartphone, specifically, step and global position system data, to quantify physical activity. The objectives were to 1) assess the agreement between surrogate-decision maker and patient self-reported estimates of distance and time walked prior to resting and daily step-count and 2) determine the feasibility of extracting premorbid physical activity (step and global position system) data from critically ill patients. Design: Prospective cohort study. Setting: Quaternary ICU. Patients: Fifty consecutively admitted adult patients who owned a smartphone, who were ambulatory at baseline, and who remained in ICU for more than 48 hours participated. Measurments and Main Results: There was no agreement between patients and surrogates for all premorbid walking metrics (mean bias 108% [99% lower to 8, 700% higher], 83% [97% to 2, 100%], and 71% [96% to 1, 080%], for distance, time, and steps, respectively). Step and/or global position system data were successfully extracted from 24 of 50 phones (48%; 95% CI, 35–62%). Surrogate-decision makers, but not patient self-reported, estimates of steps taken per day correlated with smartphone data (surrogates: n = 13, ρ = 0.56, p < 0.05; patients: n = 13, ρ = 0.30, p = 0.317). Conclusion: There was a lack of agreementAbstract : Objectives: Surrogate-decision maker and patient self-reported estimates of the distances walked prior to acute illness are subjective and may be imprecise. It may be possible to extract objective data from a patient's smartphone, specifically, step and global position system data, to quantify physical activity. The objectives were to 1) assess the agreement between surrogate-decision maker and patient self-reported estimates of distance and time walked prior to resting and daily step-count and 2) determine the feasibility of extracting premorbid physical activity (step and global position system) data from critically ill patients. Design: Prospective cohort study. Setting: Quaternary ICU. Patients: Fifty consecutively admitted adult patients who owned a smartphone, who were ambulatory at baseline, and who remained in ICU for more than 48 hours participated. Measurments and Main Results: There was no agreement between patients and surrogates for all premorbid walking metrics (mean bias 108% [99% lower to 8, 700% higher], 83% [97% to 2, 100%], and 71% [96% to 1, 080%], for distance, time, and steps, respectively). Step and/or global position system data were successfully extracted from 24 of 50 phones (48%; 95% CI, 35–62%). Surrogate-decision makers, but not patient self-reported, estimates of steps taken per day correlated with smartphone data (surrogates: n = 13, ρ = 0.56, p < 0.05; patients: n = 13, ρ = 0.30, p = 0.317). Conclusion: There was a lack of agreement between surrogate-decision maker and patient self-reported subjective estimates of distance walked. Obtaining premorbid physical activity data from the current-generation smartphones was feasible in approximately 50% of patients. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Critical care medicine. Volume 45:Issue 10(2017)
- Journal:
- Critical care medicine
- Issue:
- Volume 45:Issue 10(2017)
- Issue Display:
- Volume 45, Issue 10 (2017)
- Year:
- 2017
- Volume:
- 45
- Issue:
- 10
- Issue Sort Value:
- 2017-0045-0010-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-10
- Subjects:
- critical illness -- exercise tolerance -- physical activity -- smartphone -- technology
Critical care medicine -- Periodicals
Soins intensifs -- Périodiques
616.028 - Journal URLs:
- http://journals.lww.com/ccmjournal/Pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/CCM.0000000000002599 ↗
- Languages:
- English
- ISSNs:
- 0090-3493
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3487.451000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 5367.xml