Development of a 3D remote dosimetry protocol compatible with MRgIMRT. Issue 11 (9th October 2017)
- Record Type:
- Journal Article
- Title:
- Development of a 3D remote dosimetry protocol compatible with MRgIMRT. Issue 11 (9th October 2017)
- Main Title:
- Development of a 3D remote dosimetry protocol compatible with MRgIMRT
- Authors:
- Mein, Stewart
Rankine, Leith
Adamovics, John
Li, Harold
Oldham, Mark - Abstract:
- Abstract : Purpose: To develop a novel remote 3D dosimetry protocol to verify Magnetic Resonance‐guided Radiation Therapy (MRgRT) treatments. The protocol was applied to investigate the accuracy of TG‐119 IMRT irradiations delivered by the MRIdian ® system (ViewRay ®, Oakwood Village, OH, USA) allowing for a 48‐hour delay between irradiation at a field institution and subsequent readout at a base institution. Methods: The 3D dosimetry protocol utilizes a novel formulation of PRESAGE ® radiochromic dosimeters developed for high postirradiation stability and compatibility with optical‐CT readout. Optical‐CT readout was performed with an in‐house system utilizing telecentric lenses affording high‐resolution scanning. The protocol was developed from preparatory experiments to characterize PRESAGE ® response in relevant conditions. First, linearity and sensitivity of PRESAGE ® dose‐response in the presence of a magnetic field was evaluated in a small volume study (4 ml cuvettes) conducted under MRgRT conditions and irradiated with doses 0–15 Gy. Temporal and spatial stability of the dose‐response were investigated in large volume studies utilizing large field‐of‐view (FOV) 2 kg cylindrical PRESAGE ® dosimeters. Dosimeters were imaged at t = 1 hr and t = 48 hrs enabling the development of correction terms to model any observed spatial and temporal changes postirradiation. Polynomial correction factors for temporal and spatial changes in PRESAGE ® dosimeters ( C T and C RAbstract : Purpose: To develop a novel remote 3D dosimetry protocol to verify Magnetic Resonance‐guided Radiation Therapy (MRgRT) treatments. The protocol was applied to investigate the accuracy of TG‐119 IMRT irradiations delivered by the MRIdian ® system (ViewRay ®, Oakwood Village, OH, USA) allowing for a 48‐hour delay between irradiation at a field institution and subsequent readout at a base institution. Methods: The 3D dosimetry protocol utilizes a novel formulation of PRESAGE ® radiochromic dosimeters developed for high postirradiation stability and compatibility with optical‐CT readout. Optical‐CT readout was performed with an in‐house system utilizing telecentric lenses affording high‐resolution scanning. The protocol was developed from preparatory experiments to characterize PRESAGE ® response in relevant conditions. First, linearity and sensitivity of PRESAGE ® dose‐response in the presence of a magnetic field was evaluated in a small volume study (4 ml cuvettes) conducted under MRgRT conditions and irradiated with doses 0–15 Gy. Temporal and spatial stability of the dose‐response were investigated in large volume studies utilizing large field‐of‐view (FOV) 2 kg cylindrical PRESAGE ® dosimeters. Dosimeters were imaged at t = 1 hr and t = 48 hrs enabling the development of correction terms to model any observed spatial and temporal changes postirradiation. Polynomial correction factors for temporal and spatial changes in PRESAGE ® dosimeters ( C T and C R respectively) were obtained by numerical fitting to time‐point data acquired in six irradiated dosimeters. A remote dosimetry protocol was developed where PRESAGE ® change in optical‐density (ΔOD) readings at time t = X (the irradiation to return shipment time interval) were corrected back to a convenient standard time t = 1 hr using the C T and C R corrections. This refined protocol was then applied to TG‐119 (American Association of Physicists in Medicine, Task Group 119) plan deliveries on the MRIdian ® system to evaluate the accuracy of MRgRT in these conditions. Results: In the small volume study, in the presence of a 0.35 T magnetic field, PRESAGE ® was observed to respond linearly (R 2 = 0.9996) to Co‐60 irradiation at t = 48 hrs postirradiation, within the dose ranges of 0 to 15 Gy, with a sensitivity of 0.0305(±0.003) ΔOD cm −1 Gy −1 . In the large volume studies, at t = 1 hr postirradiation, consistent linear response was observed, with average sensitivity of 0.0930 ± 0.002 ΔOD cm −1 Gy −1 . However, dosimeters gradually darkened with time (OD< 5% per day). A small radial dependence to the dosimeter sensitivity was measured (< 3% of maximum dose), which is attributed to a spherically symmetric dosimeter artifact arising from exothermic heating legacy in the PRESAGE ® polyurethane substrate during curing. When applied to the TG‐119 IMRT irradiations, the remote dosimetry protocol (including correction terms) yielded excellent line‐profile and 3D gamma agreement for 3%/3 mm, 10% threshold (mean passing rate = 96.6% ± 4.0%). Conclusion: A novel 3D remote dosimetry protocol is introduced for validating off‐site dosimetrically complex radiotherapy systems, including MRgRT. The protocol involves correcting for temporal and spatially dependent changes in PRESAGE ® radiochromic dosimeters readout by optical‐CT. Application of the protocol to TG‐119 irradiations enabled verification of MRgRT dose distributions with high resolution. … (more)
- Is Part Of:
- Medical physics. Volume 44:Issue 11(2017)
- Journal:
- Medical physics
- Issue:
- Volume 44:Issue 11(2017)
- Issue Display:
- Volume 44, Issue 11 (2017)
- Year:
- 2017
- Volume:
- 44
- Issue:
- 11
- Issue Sort Value:
- 2017-0044-0011-0000
- Page Start:
- 6018
- Page End:
- 6028
- Publication Date:
- 2017-10-09
- Subjects:
- 3D dosimetry -- MRgIMRT -- optical‐CT -- PRESAGE ® -- quality assurance -- remote dosimetry
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.12565 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5361.xml