A universal parameterized gradient‐based method for photon beam field size determination. Issue 11 (13th October 2017)
- Record Type:
- Journal Article
- Title:
- A universal parameterized gradient‐based method for photon beam field size determination. Issue 11 (13th October 2017)
- Main Title:
- A universal parameterized gradient‐based method for photon beam field size determination
- Authors:
- Lebron, Sharon
Yan, Guanghua
Li, Jonathan
Lu, Bo
Liu, Chihray - Abstract:
- Abstract : Purpose: To propose a universal, parameterized gradient‐based method (PGM) for radiation field size determination. Methods: The PGM locates the beam profile's edge by parameterizing its penumbra region with a modified sigmoid function where the inflection point can be determined in a closed form. The parametrization was validated with filter‐flattened (FF), flattening‐filter‐free (FFF) and wedged profiles measured on two Elekta linac models (Synergy and Versa HD). Gamma analysis with the delta dose function set to zero was used to quantitatively assess the parameterization accuracy. Field sizes of FF beams were calculated with the PGM and the full width at half maximum (FWHM) methods for comparison. To assess the consistency of the PGM and the FWHM method with geometric scaling across different depths, the calculated field size at a reference depth was scaled to other depths and compared with the field sizes calculated from the measured profiles. The method was also validated against a maximum‐slope method (MSM) with wedge and FFF profiles. We also evaluated the robustness of the three methods with respect to measurement noise, varying scanning step sizes, detector characteristics, and beam energy/modality. Results: Small distance‐to‐agreement (0.02 ± 0.02 mm) between the measured and parameterized penumbra region was observed for all profiles. The differences between the field sizes calculated with the FWHM method and the PGM were consistent (0.9 ± 0.3 mm), withAbstract : Purpose: To propose a universal, parameterized gradient‐based method (PGM) for radiation field size determination. Methods: The PGM locates the beam profile's edge by parameterizing its penumbra region with a modified sigmoid function where the inflection point can be determined in a closed form. The parametrization was validated with filter‐flattened (FF), flattening‐filter‐free (FFF) and wedged profiles measured on two Elekta linac models (Synergy and Versa HD). Gamma analysis with the delta dose function set to zero was used to quantitatively assess the parameterization accuracy. Field sizes of FF beams were calculated with the PGM and the full width at half maximum (FWHM) methods for comparison. To assess the consistency of the PGM and the FWHM method with geometric scaling across different depths, the calculated field size at a reference depth was scaled to other depths and compared with the field sizes calculated from the measured profiles. The method was also validated against a maximum‐slope method (MSM) with wedge and FFF profiles. We also evaluated the robustness of the three methods with respect to measurement noise, varying scanning step sizes, detector characteristics, and beam energy/modality. Results: Small distance‐to‐agreement (0.02 ± 0.02 mm) between the measured and parameterized penumbra region was observed for all profiles. The differences between the field sizes calculated with the FWHM method and the PGM were consistent (0.9 ± 0.3 mm), with the FWHM method yielding larger values. With geometrical scaling, the PGM and the FWHM method produced maximum differences of 0.26 and 1.16 mm, respectively. For wedge and FFF beams, the mean differences relative to FF fields were 0.15 ± 0.09 mm and 0.57 ± 0.91 mm for the PGM and the MSM, respectively. The PGM was also found to produce more consistent results than the FWHM method and the MSM when measurement noise, scanning step size, detector characteristics, and beam energy/modality changed. Conclusion: The proposed PGM is universally applicable to all beam modalities (FF, wedge and FFF) for accurate field size determination. Compared to the FWHM and the MSM, it is more robust to variations in measurement condition and detection system. … (more)
- Is Part Of:
- Medical physics. Volume 44:Issue 11(2017)
- Journal:
- Medical physics
- Issue:
- Volume 44:Issue 11(2017)
- Issue Display:
- Volume 44, Issue 11 (2017)
- Year:
- 2017
- Volume:
- 44
- Issue:
- 11
- Issue Sort Value:
- 2017-0044-0011-0000
- Page Start:
- 5627
- Page End:
- 5637
- Publication Date:
- 2017-10-13
- Subjects:
- field size -- linac -- parameterization -- quality assurance
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.12573 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5361.xml