Effect of axial length on full‐field and multifocal electroretinograms. (7th March 2017)
- Record Type:
- Journal Article
- Title:
- Effect of axial length on full‐field and multifocal electroretinograms. (7th March 2017)
- Main Title:
- Effect of axial length on full‐field and multifocal electroretinograms
- Authors:
- Sachidanandam, Ramya
Ravi, Priya
Sen, Parveen - Abstract:
- Abstract : Purpose: The aim was to investigate the effect of axial length on full‐field electroretinogram (ffERG) and multifocal electroretinogram (mfERG) in young Indian subjects. Methods: One hundred subjects (44 male) with refractive errors from +0.50 to −18.00 DS and no myopic retinopathy underwent axial length measurement. ffERG was measured, which included scotopic and photopic responses according to International Society for Clinical Electrophysiology of Vision (ISCEV) guidelines. The mfERG was recorded after correcting for refractive error according to ISCEV standards. The dark‐adapted and light‐adapted parameters of ffERG and N1, P1 parameters of six rings in mfERG were analysed with axial length, controlled for refractive error. The subjects were divided into seven groups based on axial length. The b/a ratio of dark‐adapted and light‐adapted 3.0 ffERG and P1/N1 ratio of mfERG amplitudes were analysed for seven groups of axial length. Results: The axial length ranged from 21.79 to 30.55 mm. Significant negative correlations were noted for ffERG and mfERG amplitudes, whereas implicit times showed minimal delay with increase in axial length. In ffERG, the scotopic responses were more decreased compared to photopic responses. In mfERG, P1 and N1 amplitudes were significantly decreased in all the rings in all groups and more reduction was noted in the central ring compared to peripheral rings. The P1 amplitudes were more affected as compared to N1 amplitudes. TheAbstract : Purpose: The aim was to investigate the effect of axial length on full‐field electroretinogram (ffERG) and multifocal electroretinogram (mfERG) in young Indian subjects. Methods: One hundred subjects (44 male) with refractive errors from +0.50 to −18.00 DS and no myopic retinopathy underwent axial length measurement. ffERG was measured, which included scotopic and photopic responses according to International Society for Clinical Electrophysiology of Vision (ISCEV) guidelines. The mfERG was recorded after correcting for refractive error according to ISCEV standards. The dark‐adapted and light‐adapted parameters of ffERG and N1, P1 parameters of six rings in mfERG were analysed with axial length, controlled for refractive error. The subjects were divided into seven groups based on axial length. The b/a ratio of dark‐adapted and light‐adapted 3.0 ffERG and P1/N1 ratio of mfERG amplitudes were analysed for seven groups of axial length. Results: The axial length ranged from 21.79 to 30.55 mm. Significant negative correlations were noted for ffERG and mfERG amplitudes, whereas implicit times showed minimal delay with increase in axial length. In ffERG, the scotopic responses were more decreased compared to photopic responses. In mfERG, P1 and N1 amplitudes were significantly decreased in all the rings in all groups and more reduction was noted in the central ring compared to peripheral rings. The P1 amplitudes were more affected as compared to N1 amplitudes. The light‐adapted and dark‐adapted 3.0 ERG b/a ratio and P1/N1 ratio for seven axial length groups did not show statistically significant difference. The ERG parameters were not significant with refractive error. Conclusion: This study quantifies the relationship of axial length with ffERG and mfERG parameters in a young Indian population. Although the amplitudes were reduced significantly, the implicit times were not significantly affected. The ERG parameters were more related to axial length than refractive error. Hence, interpretation of ffERG and mfERG parameters needs careful consideration in subjects with increasing axial length. … (more)
- Is Part Of:
- Clinical & experimental optometry. Volume 100:Number 6(2017:Nov.)
- Journal:
- Clinical & experimental optometry
- Issue:
- Volume 100:Number 6(2017:Nov.)
- Issue Display:
- Volume 100, Issue 6 (2017)
- Year:
- 2017
- Volume:
- 100
- Issue:
- 6
- Issue Sort Value:
- 2017-0100-0006-0000
- Page Start:
- 668
- Page End:
- 675
- Publication Date:
- 2017-03-07
- Subjects:
- axial length -- full‐field electroretinogram -- multifocal electroretinogram -- myopia
Optometry -- Periodicals
Optometrists -- Services for -- Australia -- Periodicals
Optometry -- Periodicals
Optométrie -- Périodiques
617.75 - Journal URLs:
- http://www.blackwell-synergy.com/loi/cxo ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1444-0938 ↗
https://www.tandfonline.com/toc/tceo20/current ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/cxo.12529 ↗
- Languages:
- English
- ISSNs:
- 0816-4622
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.251940
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 5355.xml