LY2963016 Insulin Glargine and Insulin Glargine (Lantus) Produce Comparable Pharmacokinetics and Pharmacodynamics at Two Dose Levels. Issue 6 (21st September 2017)
- Record Type:
- Journal Article
- Title:
- LY2963016 Insulin Glargine and Insulin Glargine (Lantus) Produce Comparable Pharmacokinetics and Pharmacodynamics at Two Dose Levels. Issue 6 (21st September 2017)
- Main Title:
- LY2963016 Insulin Glargine and Insulin Glargine (Lantus) Produce Comparable Pharmacokinetics and Pharmacodynamics at Two Dose Levels
- Authors:
- Zhang, Xin
Lam, Eric Chen Quin
Seger, Mary E.
Coutant, David
Chua, Laiyi
Tan, Lai Hock
Soon, Danny
Linnebjerg, Helle - Abstract:
- Abstract: LY2963016 (LY IGlar) and Lantus (IGlar) are insulin glargine products with identical amino acid sequences. This was a phase 1 single‐site, randomized, subject‐ and investigator‐blinded, 4‐treatment, 4‐period crossover study to compare the pharmacokinetic (PK) and pharmacodynamic (PD) properties of LY IGlar and IGlar at 2 different doses. Fasted healthy subjects were randomly assigned to receive 2 single doses of LY IGlar and IGlar (0.3 and 0.6 U/kg for each product). Blood samples were collected up to 24 hours postdose to assess PK, and a euglycemic clamp lasting up to 24 hours postdose was conducted to assess PD. Twenty‐four healthy subjects aged 23 to 52 years participated in the study. The primary PK parameters (area under the concentration versus time curve from 0 to 24 hours [AUC0–24 ] and maximum observed drug concentration [Cmax ]) and PD parameters (total amount of glucose infused during the clamp [Gtot ] and maximum glucose infusion rate [Rmax ]) were not statistically different between LY IGlar and IGlar at either dose. No safety concerns were noted with either drug. The study demonstrated that the PK and PD parameters for LY IGlar and IGlar were comparable following single doses at both 0.3 and 0.6 U/kg.
- Is Part Of:
- Clinical pharmacology in drug development. Volume 6:Issue 6(2017)
- Journal:
- Clinical pharmacology in drug development
- Issue:
- Volume 6:Issue 6(2017)
- Issue Display:
- Volume 6, Issue 6 (2017)
- Year:
- 2017
- Volume:
- 6
- Issue:
- 6
- Issue Sort Value:
- 2017-0006-0006-0000
- Page Start:
- 556
- Page End:
- 563
- Publication Date:
- 2017-09-21
- Subjects:
- biosimilar insulin -- euglycemic clamp -- glucodynamics -- type 1 diabetes mellitus -- type 2 diabetes mellitus
Drugs -- Testing -- Periodicals
Drug development -- Periodicals
Clinical pharmacology -- Periodicals
615.580724 - Journal URLs:
- http://cpd.sagepub.com ↗
http://onlinelibrary.wiley.com/journal/10.1002/%28ISSN%292160-7648 ↗
http://accp1.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)2160-7648/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/cpdd.392 ↗
- Languages:
- English
- ISSNs:
- 2160-7648
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.330300
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 5355.xml