A new approach for fat removal in a discontinuous autotransfusion device–concept and evaluation. Issue 8 (27th September 2017)
- Record Type:
- Journal Article
- Title:
- A new approach for fat removal in a discontinuous autotransfusion device–concept and evaluation. Issue 8 (27th September 2017)
- Main Title:
- A new approach for fat removal in a discontinuous autotransfusion device–concept and evaluation
- Authors:
- Seyfried, T. F.
Gruber, M.
Pawlik, M. T.
Kasper, S.
Mandle, R. J.
Hansen, E. - Abstract:
- Abstract : Background: Fat present during blood salvage in orthopaedic or cardiac surgery can pose a risk of fat embolism and should be eliminated before transfusion. Based on observations of central fat accumulation at the bottom of Latham bowls, a fat reduction program was developed using two volume displacements, where blood temporarily is removed and respun in the bowl to force the fat through the RBC sediment. Materials and methods: Pooled ABO‐matched RBC and FFP were adjusted to a haematocrit of 10%, and human fat tissue added to a concentration of 1·25 vol%. In six experiments, blood was processed with the new‐generation cell salvage device CS Elite in a newly developed fat reduction program in bowls of three sizes. Volumetric quantification of fat was performed after centrifugation of blood samples in Pasteur pipettes. From volumes, haematocrits and the concentrations of fat, RBC recovery and fat elimination rates were calculated. Results: Fat removal rates of 93·2 ± 2·8, 97·0 ± 2·1 and 99·6 ± 0·3% were observed with a 70‐ml, 125‐ml and 225‐ml bowl, respectively, and even higher rates when removal rates were calculated one cycle. At the same time, high RBC recovery and plasma elimination rates were maintained, not significantly different to the default program mode. Conclusion: Modifications in process parameters and sequence led to a fat reduction program that significantly improves fat removal with the Cell Saver Elite from 77·4 ± 5·1% in the default mode to anAbstract : Background: Fat present during blood salvage in orthopaedic or cardiac surgery can pose a risk of fat embolism and should be eliminated before transfusion. Based on observations of central fat accumulation at the bottom of Latham bowls, a fat reduction program was developed using two volume displacements, where blood temporarily is removed and respun in the bowl to force the fat through the RBC sediment. Materials and methods: Pooled ABO‐matched RBC and FFP were adjusted to a haematocrit of 10%, and human fat tissue added to a concentration of 1·25 vol%. In six experiments, blood was processed with the new‐generation cell salvage device CS Elite in a newly developed fat reduction program in bowls of three sizes. Volumetric quantification of fat was performed after centrifugation of blood samples in Pasteur pipettes. From volumes, haematocrits and the concentrations of fat, RBC recovery and fat elimination rates were calculated. Results: Fat removal rates of 93·2 ± 2·8, 97·0 ± 2·1 and 99·6 ± 0·3% were observed with a 70‐ml, 125‐ml and 225‐ml bowl, respectively, and even higher rates when removal rates were calculated one cycle. At the same time, high RBC recovery and plasma elimination rates were maintained, not significantly different to the default program mode. Conclusion: Modifications in process parameters and sequence led to a fat reduction program that significantly improves fat removal with the Cell Saver Elite from 77·4 ± 5·1% in the default mode to an average of 98·6 ± 1·1%, yielding results equivalent to the continuous cell salvage system (C.A.T.S). … (more)
- Is Part Of:
- Vox sanguinis. Volume 112:Issue 8(2017)
- Journal:
- Vox sanguinis
- Issue:
- Volume 112:Issue 8(2017)
- Issue Display:
- Volume 112, Issue 8 (2017)
- Year:
- 2017
- Volume:
- 112
- Issue:
- 8
- Issue Sort Value:
- 2017-0112-0008-0000
- Page Start:
- 759
- Page End:
- 766
- Publication Date:
- 2017-09-27
- Subjects:
- RBC transfusion -- transfusion complications‐ non‐infectious -- transfusion practices (surgical)
Blood -- Periodicals
Blood -- Transfusion -- Periodicals
Immunohematology -- Periodicals
Immunopathology -- Periodicals
615.39 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1423-0410 ↗
http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=vox ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/vox.12574 ↗
- Languages:
- English
- ISSNs:
- 0042-9007
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9258.700000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5352.xml