Using weighted power mean for equivalent square estimation. (31st October 2017)
- Record Type:
- Journal Article
- Title:
- Using weighted power mean for equivalent square estimation. (31st October 2017)
- Main Title:
- Using weighted power mean for equivalent square estimation
- Authors:
- Zhou, Sumin
Wu, Qiuwen
Li, Xiaobo
Ma, Rongtao
Zheng, Dandan
Wang, Shuo
Zhang, Mutian
Li, Sicong
Lei, Yu
Fan, Qiyong
Hyun, Megan
Diener, Tyler
Enke, Charles - Abstract:
- Abstract: Purpose: Equivalent Square (ES) enables the calculation of many radiation quantities for rectangular treatment fields, based only on measurements from square fields. While it is widely applied in radiotherapy, its accuracy, especially for extremely elongated fields, still leaves room for improvement. In this study, we introduce a novel explicit ES formula based on Weighted Power Mean (WPM) function and compare its performance with the Sterling formula and Vadash/Bjärngard's formula. Methods: The proposed WPM formula is E S W P M a, b = w a α + 1 − w b α 1 / α for a rectangular photon field with sides a and b. The formula performance was evaluated by three methods: standard deviation of model fitting residual error, maximum relative model prediction error, and model's Akaike Information Criterion (AIC). Testing datasets included the ES table from British Journal of Radiology (BJR), photon output factors ( S cp ) from the Varian TrueBeam Representative Beam Data (Med Phys. 2012;39:6981–7018), and published S cp data for Varian TrueBeam Edge ( J Appl Clin Med Phys . 2015;16:125‐148). Results: For the BJR dataset, the best‐fit parameter value α = −1.25 achieved a 20% reduction in standard deviation in ES estimation residual error compared with the two established formulae. For the two Varian datasets, employing WPM reduced the maximum relative error from 3.5% (Sterling) or 2% (Vadash/Bjärngard) to 0.7% for open field sizes ranging from 3 cm to 40 cm, and the reductionAbstract: Purpose: Equivalent Square (ES) enables the calculation of many radiation quantities for rectangular treatment fields, based only on measurements from square fields. While it is widely applied in radiotherapy, its accuracy, especially for extremely elongated fields, still leaves room for improvement. In this study, we introduce a novel explicit ES formula based on Weighted Power Mean (WPM) function and compare its performance with the Sterling formula and Vadash/Bjärngard's formula. Methods: The proposed WPM formula is E S W P M a, b = w a α + 1 − w b α 1 / α for a rectangular photon field with sides a and b. The formula performance was evaluated by three methods: standard deviation of model fitting residual error, maximum relative model prediction error, and model's Akaike Information Criterion (AIC). Testing datasets included the ES table from British Journal of Radiology (BJR), photon output factors ( S cp ) from the Varian TrueBeam Representative Beam Data (Med Phys. 2012;39:6981–7018), and published S cp data for Varian TrueBeam Edge ( J Appl Clin Med Phys . 2015;16:125‐148). Results: For the BJR dataset, the best‐fit parameter value α = −1.25 achieved a 20% reduction in standard deviation in ES estimation residual error compared with the two established formulae. For the two Varian datasets, employing WPM reduced the maximum relative error from 3.5% (Sterling) or 2% (Vadash/Bjärngard) to 0.7% for open field sizes ranging from 3 cm to 40 cm, and the reduction was even more prominent for 1 cm field sizes on Edge ( J Appl Clin Med Phys . 2015;16 :125–148). The AIC value of the WPM formula was consistently lower than its counterparts from the traditional formulae on photon output factors, most prominent on very elongated small fields. Conclusion: The WPM formula outperformed the traditional formulae on three testing datasets. With increasing utilization of very elongated, small rectangular fields in modern radiotherapy, improved photon output factor estimation is expected by adopting the WPM formula in treatment planning and secondary MU check. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 18:Number 6(2017)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 18:Number 6(2017)
- Issue Display:
- Volume 18, Issue 6 (2017)
- Year:
- 2017
- Volume:
- 18
- Issue:
- 6
- Issue Sort Value:
- 2017-0018-0006-0000
- Page Start:
- 194
- Page End:
- 199
- Publication Date:
- 2017-10-31
- Subjects:
- Akaike Information Criterion -- equivalent square -- linac output factors -- weighted power mean
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.12201 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5351.xml