Quantifying tumor vascular heterogeneity with DCE‐MRI in complex adnexal masses: A preliminary study. Issue 6 (3rd April 2017)
- Record Type:
- Journal Article
- Title:
- Quantifying tumor vascular heterogeneity with DCE‐MRI in complex adnexal masses: A preliminary study. Issue 6 (3rd April 2017)
- Main Title:
- Quantifying tumor vascular heterogeneity with DCE‐MRI in complex adnexal masses: A preliminary study
- Authors:
- Thomassin‐Naggara, Isabelle
Soualhi, Narimane
Balvay, Daniel
Darai, Emile
Cuenod, Charles‐André - Abstract:
- Abstract : Purpose: To evaluate the value of quantifying dynamic contrast‐enhanced magnetic resonance imaging (DCE‐MRI) heterogeneity to characterize adnexal masses. Materials and Methods: Our database was retrospectively queried to identify all surgically proven adnexal masses characterized with a 1.5T DCE‐MRI between January 1st 2008 and February 28th 2010 ( n = 113 masses, including 52 benign, 11 borderline, and 50 invasive malignant tumors). The solid component of the adnexal mass was segmented. Quantitative analysis with a compartmental model was performed to calculate microvascular parameters, including tissue blood flow (FT ), blood volume fraction (Vb ), lag time (DAT ), interstitial volume fraction (Ve ), permeability–surface area product (PS), and relative area under curve (r AUC), were calculated. Then heterogeneity parameters were evaluated using the analysis of the evolution of the standard deviation (SD) of signal intensities on DCE‐MRI series. The area under the receiver operating characteristic (AUROC) curve was calculated to assess the overall discrimination of parameters. Results: Malignant tumors displayed higher FT, Vb, andr AUC and lower DAT than benign tumors ( P = 0.01, P < 0.0001, and P < 0.0001, respectively). Invasive malignant tumors displayed lower Vb andr AUC than borderline tumors ( P < 0.01). After injection, whenever the heterogeneity parameter was considered, malignant tumors were more heterogeneous than benign tumors, invasive tumors wereAbstract : Purpose: To evaluate the value of quantifying dynamic contrast‐enhanced magnetic resonance imaging (DCE‐MRI) heterogeneity to characterize adnexal masses. Materials and Methods: Our database was retrospectively queried to identify all surgically proven adnexal masses characterized with a 1.5T DCE‐MRI between January 1st 2008 and February 28th 2010 ( n = 113 masses, including 52 benign, 11 borderline, and 50 invasive malignant tumors). The solid component of the adnexal mass was segmented. Quantitative analysis with a compartmental model was performed to calculate microvascular parameters, including tissue blood flow (FT ), blood volume fraction (Vb ), lag time (DAT ), interstitial volume fraction (Ve ), permeability–surface area product (PS), and relative area under curve (r AUC), were calculated. Then heterogeneity parameters were evaluated using the analysis of the evolution of the standard deviation (SD) of signal intensities on DCE‐MRI series. The area under the receiver operating characteristic (AUROC) curve was calculated to assess the overall discrimination of parameters. Results: Malignant tumors displayed higher FT, Vb, andr AUC and lower DAT than benign tumors ( P = 0.01, P < 0.0001, and P < 0.0001, respectively). Invasive malignant tumors displayed lower Vb andr AUC than borderline tumors ( P < 0.01). After injection, whenever the heterogeneity parameter was considered, malignant tumors were more heterogeneous than benign tumors, invasive tumors were more heterogeneous than borderline ovarian tumors, and malignant tumors with carcinomatosis were more heterogeneous than tumors without carcinomatosis ( P < 0.001). The most discriminant parameter was the SD during the 90 seconds after injection related to arterial input function (ΔSDEARLY/AIF ) with an AUROC between 0.715 and 0.808. Conclusion: This study proposes heterogeneity parameters as a new tool with a potential for clinical application, given that the technique uses routine imaging sequences. Level of Evidence: 3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2017;46:1776–1785. … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 46:Issue 6(2017)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 46:Issue 6(2017)
- Issue Display:
- Volume 46, Issue 6 (2017)
- Year:
- 2017
- Volume:
- 46
- Issue:
- 6
- Issue Sort Value:
- 2017-0046-0006-0000
- Page Start:
- 1776
- Page End:
- 1785
- Publication Date:
- 2017-04-03
- Subjects:
- ovarian -- adnexal masses -- heterogeneity -- DCE‐MRI -- MRI
Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.25707 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5352.xml