Effect of integration time on the morphometric, densitometric and mechanical properties of the mouse tibia. (8th December 2017)
- Record Type:
- Journal Article
- Title:
- Effect of integration time on the morphometric, densitometric and mechanical properties of the mouse tibia. (8th December 2017)
- Main Title:
- Effect of integration time on the morphometric, densitometric and mechanical properties of the mouse tibia
- Authors:
- Oliviero, S.
Lu, Y.
Viceconti, M.
Dall'Ara, E. - Abstract:
- Abstract: Micro-Computed Tomography (microCT) images are used to measure morphometric and densitometric properties of bone, and to develop finite element (FE) models to estimate mechanical properties. However, there are concerns about the invasiveness of microCT imaging due to the X-rays ionising radiation induced by the repeated scans on the same animal. Therefore, the best compromise between radiation dose and image quality should be chosen for each preclinical application. In this study, we investigated the effect of integration time (time the bone is exposed to radiation at each rotation step during microCT imaging) on measurements performed on the mouse tibia. Four tibiae were scanned at 10.4 µm voxel size using four different procedures, characterized by decreasing integration time (from 200 ms to 50 ms) and therefore decreasing nominal radiation dose (from 513 mGy to 128 mGy). From each image, trabecular and cortical morphometric parameters, spatial distribution of bone mineral content (BMC) in the whole tibia and FE-based estimations of stiffness and strength were obtained. A high-resolution scan (4.3 µm voxel size) was used to quantify measurement errors. Integration time had the largest effect on trabecular morphometric parameters (7–28%). Lower effects were observed on cortical parameters (1–3%), BMC (1–10%) distribution, and FE-based estimations of mechanical properties (1–3%). In conclusion, the effect of integration time on image-based measurements has beenAbstract: Micro-Computed Tomography (microCT) images are used to measure morphometric and densitometric properties of bone, and to develop finite element (FE) models to estimate mechanical properties. However, there are concerns about the invasiveness of microCT imaging due to the X-rays ionising radiation induced by the repeated scans on the same animal. Therefore, the best compromise between radiation dose and image quality should be chosen for each preclinical application. In this study, we investigated the effect of integration time (time the bone is exposed to radiation at each rotation step during microCT imaging) on measurements performed on the mouse tibia. Four tibiae were scanned at 10.4 µm voxel size using four different procedures, characterized by decreasing integration time (from 200 ms to 50 ms) and therefore decreasing nominal radiation dose (from 513 mGy to 128 mGy). From each image, trabecular and cortical morphometric parameters, spatial distribution of bone mineral content (BMC) in the whole tibia and FE-based estimations of stiffness and strength were obtained. A high-resolution scan (4.3 µm voxel size) was used to quantify measurement errors. Integration time had the largest effect on trabecular morphometric parameters (7–28%). Lower effects were observed on cortical parameters (1–3%), BMC (1–10%) distribution, and FE-based estimations of mechanical properties (1–3%). In conclusion, the effect of integration time on image-based measurements has been quantified. This data should be considered when defining the in vivo microCT scanning protocols in order to find the best compromise between nominal radiation exposure and accuracy in the estimation of bone parameters. … (more)
- Is Part Of:
- Journal of biomechanics. Volume 65(2017)
- Journal:
- Journal of biomechanics
- Issue:
- Volume 65(2017)
- Issue Display:
- Volume 65, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 65
- Issue:
- 2017
- Issue Sort Value:
- 2017-0065-2017-0000
- Page Start:
- 203
- Page End:
- 211
- Publication Date:
- 2017-12-08
- Subjects:
- Mouse tibia -- micro-CT -- Scanning -- Morphometric -- Bone mineral -- Finite element
Animal mechanics -- Periodicals
Biomechanics -- Periodicals
Biomechanics -- Periodicals
Mécanique animale -- Périodiques
Biomécanique -- Périodiques
Electronic journals
571.4305 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00219290 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/00219290 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00219290 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jbiomech.2017.10.026 ↗
- Languages:
- English
- ISSNs:
- 0021-9290
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4953.600000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5348.xml