- Deepakumari, H.N.
Mallegowda, S.M.
Prashanth, M.K.
Revanasiddappa, H.D. - Abstract:
- Abstract: A highly sensitive, selective and validated high performance liquid chromatography (HPLC) method has been developed for the quantitative determination of efavirenz in human CPDA plasma. The analyte and internal standard (IS) duloxetin (DXT) were extracted from human plasma using liquid-liquid extraction technique, then separated on a BDS hypersil C18 (15cm, 4.6mm x 5μm), reverse phase column using a mobile phase comprising of acetonitrile and 50 mM sodium dihydrogen orthophosphate solution (pH 5.5) (48:52, v/v) and column oven temperature was maintained at 30 °C. It was pumped at a flow rate of 0.8 mL/min with an injection volume of 15 µL, with a total run time of 15 min. The detection was performed on a tandem mass spectrometer equipped with electro spray ionization (ESI) source. Calibration curve for EFZ was linear within the selected range of 0.03–4.57 µg/mL in human plasma with mean correlation coefficient of 0.999. The LLOQ for efavirenz was found to be 0.03 µg/mL. The intra- and inter-assay precision and accuracy of the quality control samples, expressed as the percent relative standard deviation (% RSD) was less than 2%. The mean recovery was 96.63% to 112.71%, for EFZ and DXT, respectively. This method has been demonstrated to be an improvement over existing methods due to its greater sensitivity and specificity. The data obtained show that the sensitivity and selectivity of this method are adequate for drug monitoring in clinical research andAbstract: A highly sensitive, selective and validated high performance liquid chromatography (HPLC) method has been developed for the quantitative determination of efavirenz in human CPDA plasma. The analyte and internal standard (IS) duloxetin (DXT) were extracted from human plasma using liquid-liquid extraction technique, then separated on a BDS hypersil C18 (15cm, 4.6mm x 5μm), reverse phase column using a mobile phase comprising of acetonitrile and 50 mM sodium dihydrogen orthophosphate solution (pH 5.5) (48:52, v/v) and column oven temperature was maintained at 30 °C. It was pumped at a flow rate of 0.8 mL/min with an injection volume of 15 µL, with a total run time of 15 min. The detection was performed on a tandem mass spectrometer equipped with electro spray ionization (ESI) source. Calibration curve for EFZ was linear within the selected range of 0.03–4.57 µg/mL in human plasma with mean correlation coefficient of 0.999. The LLOQ for efavirenz was found to be 0.03 µg/mL. The intra- and inter-assay precision and accuracy of the quality control samples, expressed as the percent relative standard deviation (% RSD) was less than 2%. The mean recovery was 96.63% to 112.71%, for EFZ and DXT, respectively. This method has been demonstrated to be an improvement over existing methods due to its greater sensitivity and specificity. The data obtained show that the sensitivity and selectivity of this method are adequate for drug monitoring in clinical research and pharmacokinetic investigation of EFZ … (more)
- Is Part Of:
- Materials today. Volume 4:Number 11(2017)Part 3
- Journal:
- Materials today
- Issue:
- Volume 4:Number 11(2017)Part 3
- Issue Display:
- Volume 4, Issue 11, Part 3 (2017)
- Year:
- 2017
- Volume:
- 4
- Issue:
- 11
- Part:
- 3
- Issue Sort Value:
- 2017-0004-0011-0003
- Page Start:
- 11939
- Page End:
- 11946
- Publication Date:
- 2017
- Subjects:
- Efavirenz -- Duloxetin -- HPLC -- Pharmacokinetic investigation
Materials science -- Congresses -- Periodicals
620.1 - Journal URLs:
- http://www.sciencedirect.com/science/journal/22147853 ↗
http://www.sciencedirect.com/ ↗ - DOI:
- 10.1016/j.matpr.2017.09.115 ↗
- Languages:
- English
- ISSNs:
- 2214-7853
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5325.xml