Graphite Oxide and Gold Nanoparticles as Alternative Materials in the Design of a Highly Sensitive Electrochemical Sensor for the Simultaneous Determination of Biological Species. Issue 11 (11th August 2017)
- Record Type:
- Journal Article
- Title:
- Graphite Oxide and Gold Nanoparticles as Alternative Materials in the Design of a Highly Sensitive Electrochemical Sensor for the Simultaneous Determination of Biological Species. Issue 11 (11th August 2017)
- Main Title:
- Graphite Oxide and Gold Nanoparticles as Alternative Materials in the Design of a Highly Sensitive Electrochemical Sensor for the Simultaneous Determination of Biological Species
- Authors:
- Wong, Ademar
Silva, Tiago Almeida
Fatibello‐Filho, Orlando - Abstract:
- Abstract: New aspects related to electrochemical performance of modified carbon paste electrodes (CPE) of high analytical performance are presented in this work. We studied whether the functionalisation of graphite powder with oxygenated functional groups (graphite oxide, GrO) could affect the electrochemical features of a classical CPE. By introducing oxygen termination over the graphite surface, a remarkable improvement in electrochemical performance was verified, including enhancement of analytical signals and charge transfer kinetics, as demonstrated from electrochemical characterisation assays conducted by cyclic voltammetry and electrochemical impedance spectroscopy towards the potassium hexa‐cyanoferrate (II/III) probe. In addition, a positive effect was noted from the anchoring of Au nanoparticles on GrOPE. In analytical terms, two biologically relevant molecules were simultaneously determined using the proposed modified electrode based on GrO and AuNPs: epinephrine (EP) and uric acid (UA). Using differential pulse voltammetry (DPV), wide linear concentration ranges were founded for the analytical curves of EP and UA, and the limits of detection of 1.0×10 −7 mol L −1 (EP) and 5.0×10 −8 mol L −1 (UA) were predicted, respectively. The designed electrochemical sensor showed excellent precision of measurement and appropriate applicability for the analysis of biological fluids. Abstract :
- Is Part Of:
- Electroanalysis. Volume 29:Issue 11(2017)
- Journal:
- Electroanalysis
- Issue:
- Volume 29:Issue 11(2017)
- Issue Display:
- Volume 29, Issue 11 (2017)
- Year:
- 2017
- Volume:
- 29
- Issue:
- 11
- Issue Sort Value:
- 2017-0029-0011-0000
- Page Start:
- 2491
- Page End:
- 2497
- Publication Date:
- 2017-08-11
- Subjects:
- Graphite Oxide -- Gold Nanoparticles -- Uric Acid -- Epinephrine -- Simultaneous Determination
Electrochemical analysis -- Periodicals
Chemistry, Analytical -- Periodicals
Electrochemistry -- Periodicals
543.4 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1521-4109 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/elan.201700357 ↗
- Languages:
- English
- ISSNs:
- 1040-0397
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3698.789000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5325.xml