An investigation of the beam damage effect on in situ liquid secondary ion mass spectrometry analysis. (30th October 2017)
- Record Type:
- Journal Article
- Title:
- An investigation of the beam damage effect on in situ liquid secondary ion mass spectrometry analysis. (30th October 2017)
- Main Title:
- An investigation of the beam damage effect on in situ liquid secondary ion mass spectrometry analysis
- Authors:
- Yu, Xiaofei
Yu, Jiachao
Zhou, Yufan
Zhang, Yanyan
Wang, Jungang
Evans, James E.
Yu, Xiao‐Ying
Wang, Xue‐Lin
Zhu, Zihua - Abstract:
- Abstract : Rationale: During in situ liquid secondary ion mass spectrometry (SIMS) analysis, the primary ion beam is normally scanned on a very small area to collect signals with high ion doses (10 14 to 10 16 ions/cm 2 ). As a result, beam damage may become a concern when compared with the static limit of SIMS analysis, in which the dose is normally less than 10 12 ions/cm 2 . Therefore, a comparison of ion yields in in situ liquid SIMS analysis versus traditional static SIMS analysis of corresponding dry samples is of great interest. Methods: In this study, a dipalmitoylphosphatidylcholine (DPPC) liposome solution was used as a model system. Both liquid sample and dry sample were examined. Secondary ion yields using three primary ion species (Bi +, Bi3 + and Bi3 ++ ) with various beam currents were investigated. Results: Usable ion yields for both positive and negative characteristic signals (including molecular ions and characteristic fragment ions) were achievable based on optimized experimental conditions for in situ liquid SIMS analysis. The ion yield of the key DPPC molecular ion was comparable to that of traditional static SIMS, and unexpected low fragmentation was observed. The flexible structure of the liquid plays an important role for these observations. Conclusions: Therefore, beam damage may not be a concern in in situ liquid SIMS analysis if proper experimental conditions are used.
- Is Part Of:
- Rapid communications in mass spectrometry. Volume 31:Number 23(2017)
- Journal:
- Rapid communications in mass spectrometry
- Issue:
- Volume 31:Number 23(2017)
- Issue Display:
- Volume 31, Issue 23 (2017)
- Year:
- 2017
- Volume:
- 31
- Issue:
- 23
- Issue Sort Value:
- 2017-0031-0023-0000
- Page Start:
- 2035
- Page End:
- 2042
- Publication Date:
- 2017-10-30
- Subjects:
- Mass spectrometry -- Periodicals
543.65 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/rcm.7983 ↗
- Languages:
- English
- ISSNs:
- 0951-4198
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7254.440000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 5344.xml