Anatomical and radiological evaluation of less invasive stabilisation system (LISS) in correlation with knee lateral collateral ligament insertion. (November 2017)
- Record Type:
- Journal Article
- Title:
- Anatomical and radiological evaluation of less invasive stabilisation system (LISS) in correlation with knee lateral collateral ligament insertion. (November 2017)
- Main Title:
- Anatomical and radiological evaluation of less invasive stabilisation system (LISS) in correlation with knee lateral collateral ligament insertion
- Authors:
- Freimoser, Florian
Grechenig, Stephan
Ofenhitzer, Anna
Bakota, Bore
Staresinic, Mario
Pfeifer, Christian G. - Abstract:
- Abstract: Introduction: The Less Invasive Stabilisation System (LISS) is an angle-stable plate that enables treatment of distal femoral comminuted and periprosthetic fracture. As it is placed through a minimally-invasive lateral approach, lateral knee pain is a commonly described symptom after its application. This study investigates knee lateral collateral ligament (LCL) iatrogenic injury during LISS plate fixation. A cadaver study was performed and a retrospective radiological investigation with the analysis of its clinical application was conducted to evaluate possible knee LCL damage. Methods: The cadaver study included 13 human lower extremities, treated with LISS. After application, lateral knee side was dissected, implants were removed and distances between the drill holes and LCL origin were measured. In the retrospective radiological evaluation, postoperative X-rays for patients treated with distal femoral LISS plate in the University Hospital Regensburg, Germany from January 2010 to December 2015 were examined. Following a protocol described by Pietrini et al ., the LCL origin on postoperative X-rays was calculated, both in lateral and anterior-posterior (AP) view, and distances between the plate and its closest locking screw to the LCL origin were measured. Results: In the cadaver study, the mean distance between the closest drilling hole and the ligament origin was 14.0 mm (range 9–21 mm; SD 3.8 mm). Twenty-two patients matched the inclusion criteria for theAbstract: Introduction: The Less Invasive Stabilisation System (LISS) is an angle-stable plate that enables treatment of distal femoral comminuted and periprosthetic fracture. As it is placed through a minimally-invasive lateral approach, lateral knee pain is a commonly described symptom after its application. This study investigates knee lateral collateral ligament (LCL) iatrogenic injury during LISS plate fixation. A cadaver study was performed and a retrospective radiological investigation with the analysis of its clinical application was conducted to evaluate possible knee LCL damage. Methods: The cadaver study included 13 human lower extremities, treated with LISS. After application, lateral knee side was dissected, implants were removed and distances between the drill holes and LCL origin were measured. In the retrospective radiological evaluation, postoperative X-rays for patients treated with distal femoral LISS plate in the University Hospital Regensburg, Germany from January 2010 to December 2015 were examined. Following a protocol described by Pietrini et al ., the LCL origin on postoperative X-rays was calculated, both in lateral and anterior-posterior (AP) view, and distances between the plate and its closest locking screw to the LCL origin were measured. Results: In the cadaver study, the mean distance between the closest drilling hole and the ligament origin was 14.0 mm (range 9–21 mm; SD 3.8 mm). Twenty-two patients matched the inclusion criteria for the retrospective radiological study. In lateral view, the mean distance between the origin and the closest locking screw was 6.3 mm (range 0–16.4 mm; SD 4.7 mm); the mean distance between the origin and the plate was 3.1 mm (range 0–13.9 mm; SD 4.1 mm). In AP view, the mean distance between LCL origin and the nearest screw was 2.4 mm (range 0–7.6 mm; SD 2.4 mm). The mean distance between the origin and the most distal locking screw was 9.2 mm (range 0–17.5 mm; SD 4.0 mm). Discussion: The LISS is a safe option to treat distal femoral fractures in respect to the LCL. Due to close proximity, the LCL might be harmed; therefore, lateral knee pain or lateral instability after implantation should be assessed in further treatment. … (more)
- Is Part Of:
- Injury. Volume 48(2017)Supplement 5
- Journal:
- Injury
- Issue:
- Volume 48(2017)Supplement 5
- Issue Display:
- Volume 48, Issue 5 (2017)
- Year:
- 2017
- Volume:
- 48
- Issue:
- 5
- Issue Sort Value:
- 2017-0048-0005-0000
- Page Start:
- S56
- Page End:
- S60
- Publication Date:
- 2017-11
- Subjects:
- distal femoral fracture -- periprosthetic fracture -- lateral collateral ligament -- outcome -- lateral knee pain -- femur
Wounds and injuries -- Surgery -- Periodicals
Accidents -- Periodicals
Wounds and Injuries -- surgery -- Periodicals
Lésions et blessures -- Chirurgie -- Périodiques
Electronic journals
Electronic journals
617.1 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00201383 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/00201383 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00201383 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/S0020-1383(17)30741-6 ↗
- Languages:
- English
- ISSNs:
- 0020-1383
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4514.400000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5343.xml