Double-Row Arthroscopic Rotator Cuff Repair Is More Cost-Effective Than Single-Row Repair. (18th October 2017)
- Record Type:
- Journal Article
- Title:
- Double-Row Arthroscopic Rotator Cuff Repair Is More Cost-Effective Than Single-Row Repair. (18th October 2017)
- Main Title:
- Double-Row Arthroscopic Rotator Cuff Repair Is More Cost-Effective Than Single-Row Repair
- Authors:
- Huang, Adrian L.
Thavorn, Kednapa
van Katwyk, Sasha
MacDonald, Peter
Lapner, Peter - Abstract:
- Abstract : Background: The optimal technique for arthroscopic rotator cuff repair is controversial, and both single and double-row techniques are commonly used. In the current era of increasing costs, health-care delivery models are focusing on the value of care. In this study, we compared the cost-effectiveness of single-row and double-row reconstructions in patients undergoing arthroscopic rotator cuff repair. Methods: A cost-utility analysis was performed from the perspective of a publicly funded health-care system. Health-care costs, probabilities, and utility values were derived from the published literature. Efficacy data were obtained from a previous randomized controlled trial comparing the effect of single-row (n = 48) or double-row (n = 42) reconstruction among 90 surgical patients. Unit cost data were obtained from a hospital database and the Ontario Schedule of Benefits and Fees. Results are presented as an incremental cost per quality-adjusted life year (QALY) gained. All costs are presented in 2015 Canadian dollars. A series of 1-way and probabilistic sensitivity analyses were performed. Results: Double-row fixation was more costly ($2, 134.41 compared with $1, 654.76) but was more effective than the single-row method (4.073 compared with 4.055 QALYs). An incremental cost-effectiveness ratio (ICER) was estimated to be $26, 666.75 per QALY gained for double-row relative to single-row fixation. A subgroup analysis demonstrated that patients with larger rotatorAbstract : Background: The optimal technique for arthroscopic rotator cuff repair is controversial, and both single and double-row techniques are commonly used. In the current era of increasing costs, health-care delivery models are focusing on the value of care. In this study, we compared the cost-effectiveness of single-row and double-row reconstructions in patients undergoing arthroscopic rotator cuff repair. Methods: A cost-utility analysis was performed from the perspective of a publicly funded health-care system. Health-care costs, probabilities, and utility values were derived from the published literature. Efficacy data were obtained from a previous randomized controlled trial comparing the effect of single-row (n = 48) or double-row (n = 42) reconstruction among 90 surgical patients. Unit cost data were obtained from a hospital database and the Ontario Schedule of Benefits and Fees. Results are presented as an incremental cost per quality-adjusted life year (QALY) gained. All costs are presented in 2015 Canadian dollars. A series of 1-way and probabilistic sensitivity analyses were performed. Results: Double-row fixation was more costly ($2, 134.41 compared with $1, 654.76) but was more effective than the single-row method (4.073 compared with 4.055 QALYs). An incremental cost-effectiveness ratio (ICER) was estimated to be $26, 666.75 per QALY gained for double-row relative to single-row fixation. A subgroup analysis demonstrated that patients with larger rotator cuff tears (≥3 cm) had a lower ICER, suggesting that double-row fixation may be more cost-effective for larger tears. Conclusions: Based on the willingness-to-pay threshold of $50, 000 per QALY gained, double-row fixation was found to be more cost-effective than single-row. Furthermore, a double-row reconstruction was found to be more economically attractive for larger rotator cuff tears (≥3 cm). Level of Evidence: Economic and Decision AnalysisLevel IV . See Instructions for Authors for a complete description of levels of evidence. … (more)
- Is Part Of:
- Journal of bone and joint surgery. Volume 99:Number 20(2017)
- Journal:
- Journal of bone and joint surgery
- Issue:
- Volume 99:Number 20(2017)
- Issue Display:
- Volume 99, Issue 20 (2017)
- Year:
- 2017
- Volume:
- 99
- Issue:
- 20
- Issue Sort Value:
- 2017-0099-0020-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-10-18
- Subjects:
- Bones -- Surgery -- Periodicals
Joints -- Surgery -- Periodicals
Orthopedics -- Periodicals
Orthopedics
General Surgery
Bone Diseases
Joint Diseases
Bones -- Surgery
Joints -- Surgery
Orthopedics
Bot (anatomie)
Gewrichten
Chirurgie (geneeskunde)
Periodicals
Electronic journals
Periodicals
617.47005 - Journal URLs:
- http://www.clinicalkey.com/dura/browse/journalIssue/00219355 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00219355 ↗
http://www.ejbjs.org/contents-by-date.0.dtl ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&PAGE=toc&D=ovft&MODE=ovid&NEWS=N&AN=00002060-000000000-00000 ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.2106/JBJS.16.01044 ↗
- Languages:
- English
- ISSNs:
- 0021-9355
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.250000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5346.xml