A baseline drift detrending technique for fast scan cyclic voltammetry. Issue 22 (24th October 2017)
- Record Type:
- Journal Article
- Title:
- A baseline drift detrending technique for fast scan cyclic voltammetry. Issue 22 (24th October 2017)
- Main Title:
- A baseline drift detrending technique for fast scan cyclic voltammetry
- Authors:
- DeWaele, Mark
Oh, Yoonbae
Park, Cheonho
Kang, Yu Min
Shin, Hojin
Blaha, Charles D.
Bennet, Kevin E.
Kim, In Young
Lee, Kendall H.
Jang, Dong Pyo - Abstract:
- Abstract : A simple, and yet robust, high pass filter is designed to remove non-linear background drift in fast scan cyclic voltammetry. Abstract : Fast scan cyclic voltammetry (FSCV) has been commonly used to measure extracellular neurotransmitter concentrations in the brain. Due to the unstable nature of the background currents inherent in FSCV measurements, analysis of FSCV data is limited to very short amounts of time using traditional background subtraction. In this paper, we propose the use of a zero-phase high pass filter (HPF) as the means to remove the background drift. Instead of the traditional method of low pass filtering across voltammograms to increase the signal to noise ratio, a HPF with a low cutoff frequency was applied to the temporal dataset at each voltage point to remove the background drift. As a result, the HPF utilizing cutoff frequencies between 0.001 Hz and 0.01 Hz could be effectively used to a set of FSCV data for removing the drifting patterns while preserving the temporal kinetics of the phasic dopamine response recorded in vivo . In addition, compared to a drift removal method using principal component analysis, this was found to be significantly more effective in reducing the drift (unpaired t -test p < 0.0001, t = 10.88) when applied to data collected from Tris buffer over 24 hours although a drift removal method using principal component analysis also showed the effective background drift reduction. The HPF was also applied to 5 hours ofAbstract : A simple, and yet robust, high pass filter is designed to remove non-linear background drift in fast scan cyclic voltammetry. Abstract : Fast scan cyclic voltammetry (FSCV) has been commonly used to measure extracellular neurotransmitter concentrations in the brain. Due to the unstable nature of the background currents inherent in FSCV measurements, analysis of FSCV data is limited to very short amounts of time using traditional background subtraction. In this paper, we propose the use of a zero-phase high pass filter (HPF) as the means to remove the background drift. Instead of the traditional method of low pass filtering across voltammograms to increase the signal to noise ratio, a HPF with a low cutoff frequency was applied to the temporal dataset at each voltage point to remove the background drift. As a result, the HPF utilizing cutoff frequencies between 0.001 Hz and 0.01 Hz could be effectively used to a set of FSCV data for removing the drifting patterns while preserving the temporal kinetics of the phasic dopamine response recorded in vivo . In addition, compared to a drift removal method using principal component analysis, this was found to be significantly more effective in reducing the drift (unpaired t -test p < 0.0001, t = 10.88) when applied to data collected from Tris buffer over 24 hours although a drift removal method using principal component analysis also showed the effective background drift reduction. The HPF was also applied to 5 hours of FSCV in vivo data. Electrically evoked dopamine peaks, observed in the nucleus accumbens, were clearly visible even without background subtraction. This technique provides a new, simple, and yet robust, approach to analyse FSCV data with an unstable background. … (more)
- Is Part Of:
- Analyst. Volume 142:Issue 22(2017)
- Journal:
- Analyst
- Issue:
- Volume 142:Issue 22(2017)
- Issue Display:
- Volume 142, Issue 22 (2017)
- Year:
- 2017
- Volume:
- 142
- Issue:
- 22
- Issue Sort Value:
- 2017-0142-0022-0000
- Page Start:
- 4317
- Page End:
- 4321
- Publication Date:
- 2017-10-24
- Subjects:
- Chemistry, Analytic -- Periodicals
543 - Journal URLs:
- http://pubs.rsc.org/en/journals/journalissues/an?e=1#!issueid=an139020&type=current&issnprint=0003-2654 ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c7an01465a ↗
- Languages:
- English
- ISSNs:
- 0003-2654
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0893.000000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 5315.xml