Effect of Axial Length on Macular Ganglion Cell Complex Thickness and on Early Glaucoma Diagnosis by Spectral-Domain Optical Coherence Tomography. Issue 5 (May 2016)
- Record Type:
- Journal Article
- Title:
- Effect of Axial Length on Macular Ganglion Cell Complex Thickness and on Early Glaucoma Diagnosis by Spectral-Domain Optical Coherence Tomography. Issue 5 (May 2016)
- Main Title:
- Effect of Axial Length on Macular Ganglion Cell Complex Thickness and on Early Glaucoma Diagnosis by Spectral-Domain Optical Coherence Tomography
- Authors:
- Nakanishi, Hideo
Akagi, Tadamichi
Hangai, Masanori
Kimura, Yugo
Suda, Kenji
Hasegawa, Tomoko
Yamada, Hiroshi
Yoshikawa, Munemitsu
Morooka, Satoshi
Ikeda, Hanako Ohashi
Yoshimura, Nagahisa - Abstract:
- Abstract : Purpose: To investigate the effects of the axial length (AL)-related ocular magnification on the thickness of the macular ganglion cell complex (mGCC), and the diagnostic accuracy of the built-in normative database of the spectral-domain optical coherence tomographic (SD-OCT) instrument for early glaucoma detection. Methods: This retrospective study included 41 eyes with early primary open-angle glaucoma and 36 normal eyes. The mGCC thickness within a 20-degree circle, equivalent to a 6 mm diameter in the Gullstrand model eye, was measured in the SD-OCT images. The magnification effect was corrected using Bennett formula, and the mGCC thickness within the actual 6 mm diameter circle was determined. Results: In normal eyes, the inferior corrected mGCC was significantly correlated with the AL (β=−0.40, P =0.028), but correction for the magnification reduced the correlation. In 38 nonhighly myopic eyes, the sensitivity and specificity of the SD-OCT's significance maps for distinguishing early glaucoma were 95.0% and 94.4% when using either the uncorrected or the corrected mGCC. In 39 highly myopic eyes, the diagnostic accuracy was lower when using the uncorrected mGCC thickness (sensitivity was 95.2% and specificity was 44.4%), and was not improved when using the corrected mGCC (81.0% and 61.1%, respectively). Conclusions: The inferior mGCC was thinner in eyes with longer AL. The accuracy of the diagnosis with the SD-OCT built-in normative database for early glaucomaAbstract : Purpose: To investigate the effects of the axial length (AL)-related ocular magnification on the thickness of the macular ganglion cell complex (mGCC), and the diagnostic accuracy of the built-in normative database of the spectral-domain optical coherence tomographic (SD-OCT) instrument for early glaucoma detection. Methods: This retrospective study included 41 eyes with early primary open-angle glaucoma and 36 normal eyes. The mGCC thickness within a 20-degree circle, equivalent to a 6 mm diameter in the Gullstrand model eye, was measured in the SD-OCT images. The magnification effect was corrected using Bennett formula, and the mGCC thickness within the actual 6 mm diameter circle was determined. Results: In normal eyes, the inferior corrected mGCC was significantly correlated with the AL (β=−0.40, P =0.028), but correction for the magnification reduced the correlation. In 38 nonhighly myopic eyes, the sensitivity and specificity of the SD-OCT's significance maps for distinguishing early glaucoma were 95.0% and 94.4% when using either the uncorrected or the corrected mGCC. In 39 highly myopic eyes, the diagnostic accuracy was lower when using the uncorrected mGCC thickness (sensitivity was 95.2% and specificity was 44.4%), and was not improved when using the corrected mGCC (81.0% and 61.1%, respectively). Conclusions: The inferior mGCC was thinner in eyes with longer AL. The accuracy of the diagnosis with the SD-OCT built-in normative database for early glaucoma was not improved significantly by the correction of the AL-associated magnification in highly myopic eyes. Evaluation of highly myopic eyes with the nonhighly myopic normative database can lead to misdiagnosis. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Journal of glaucoma. Volume 25:Issue 5(2016:Jun./Jul.)
- Journal:
- Journal of glaucoma
- Issue:
- Volume 25:Issue 5(2016:Jun./Jul.)
- Issue Display:
- Volume 25, Issue 5 (2016)
- Year:
- 2016
- Volume:
- 25
- Issue:
- 5
- Issue Sort Value:
- 2016-0025-0005-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-05
- Subjects:
- glaucoma -- high myopia -- ganglion cell complex -- axial length -- ocular magnification -- normative database
Glaucoma -- Periodicals
617.741005 - Journal URLs:
- http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00061198-000000000-00000 ↗
http://www.glaucomajournal.com ↗
http://journals.lww.com/glaucomajournal/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/IJG.0000000000000330 ↗
- Languages:
- English
- ISSNs:
- 1057-0829
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4996.230000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5303.xml