Technical feasibility of personalized articulating knee joint distraction for treatment of tibiofemoral osteoarthritis. (November 2017)
- Record Type:
- Journal Article
- Title:
- Technical feasibility of personalized articulating knee joint distraction for treatment of tibiofemoral osteoarthritis. (November 2017)
- Main Title:
- Technical feasibility of personalized articulating knee joint distraction for treatment of tibiofemoral osteoarthritis
- Authors:
- Struik, T.
Jaspers, J.E.N.
Besselink, N.J.
van Roermund, P.M.
Plomp, S.
Rudert, M.J.
Lafeber, F.P.J.G.
Mastbergen, S.C. - Abstract:
- Abstract: Background: Knee osteoarthritis is a highly prevalent degenerative joint disorder characterized by joint tissue damage and pain. Knee joint distraction has been introduced as a joint preserving surgical procedure to postpone knee arthroplasty. An often used standard externally fixation device for distraction poses a burden to patients due to the absence of joint flexion during the 6 weeks treatment. Therefore, a personalized articulating distraction device was developed. The aim of this study was to test technical feasibility of this device. Methods: Based on an often applied rigid device, using equal bone pin positions and connectors, a hinge mechanism was developed consisting of a cam-following system for reproducing the complex joint-specific knee kinematics. In support, a device was developed for capturing the joint-specific sagittal plane articulation. The obtained kinematic data were translated into joint-specific cam shapes that were installed bilaterally in the hinge mechanism of the distraction device, as such providing personalized knee motion. Distraction of 5 mm was performed within a range of motion of 30 deg. joint flexion. Pre-clinical evaluation of the working principle was performed on human cadaveric legs and system stiffness characteristics were biomechanically evaluated. Findings: The desired range of motion was obtained and distraction was maintained under physiologically representative loading. Moreover, the joint-specific approachAbstract: Background: Knee osteoarthritis is a highly prevalent degenerative joint disorder characterized by joint tissue damage and pain. Knee joint distraction has been introduced as a joint preserving surgical procedure to postpone knee arthroplasty. An often used standard externally fixation device for distraction poses a burden to patients due to the absence of joint flexion during the 6 weeks treatment. Therefore, a personalized articulating distraction device was developed. The aim of this study was to test technical feasibility of this device. Methods: Based on an often applied rigid device, using equal bone pin positions and connectors, a hinge mechanism was developed consisting of a cam-following system for reproducing the complex joint-specific knee kinematics. In support, a device was developed for capturing the joint-specific sagittal plane articulation. The obtained kinematic data were translated into joint-specific cam shapes that were installed bilaterally in the hinge mechanism of the distraction device, as such providing personalized knee motion. Distraction of 5 mm was performed within a range of motion of 30 deg. joint flexion. Pre-clinical evaluation of the working principle was performed on human cadaveric legs and system stiffness characteristics were biomechanically evaluated. Findings: The desired range of motion was obtained and distraction was maintained under physiologically representative loading. Moreover, the joint-specific approach demonstrated tolerance of deviations from anatomical and alignment origin during initial placement of the developed distraction device. Interpretation: Articulation during knee distraction is considered technically feasible and has potential to decrease burden and improve acceptance of distraction therapy. Testing of clinical feasibility is warranted. Highlights: Joint distraction for knee osteoarthritis can postpone a total knee prosthesis. More comfort during distraction is demanded, such as an articulating frame. A joint-specific articulating knee distractor was tested for technical feasibility. Sagittal reproduction of joints-specific articulation was demonstrated. Biomechanical equality confirmed technical feasibility of the articulating device. … (more)
- Is Part Of:
- Clinical biomechanics. Volume 49(2017)
- Journal:
- Clinical biomechanics
- Issue:
- Volume 49(2017)
- Issue Display:
- Volume 49, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 49
- Issue:
- 2017
- Issue Sort Value:
- 2017-0049-2017-0000
- Page Start:
- 40
- Page End:
- 47
- Publication Date:
- 2017-11
- Subjects:
- Joint distraction -- Knee osteoarthritis -- Joint specific -- Personalized -- Articulating -- Biomechanical testing
Biomechanics -- Periodicals
Osteopathic medicine -- Periodicals
Biomechanics -- Periodicals
Osteopathic Medicine -- Periodicals
612.76 - Journal URLs:
- http://www.sciencedirect.com/science/journal/02680033 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.clinbiomech.2017.08.002 ↗
- Languages:
- English
- ISSNs:
- 0268-0033
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.262800
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5296.xml