Role of different vascular approaches on transcatheter aortic valve implantation outcome: a single-center study. Issue 4 (April 2015)
- Record Type:
- Journal Article
- Title:
- Role of different vascular approaches on transcatheter aortic valve implantation outcome: a single-center study. Issue 4 (April 2015)
- Main Title:
- Role of different vascular approaches on transcatheter aortic valve implantation outcome
- Authors:
- Adamo, Marianna
Fiorina, Claudia
Curello, Salvatore
Maffeo, Diego
Chizzola, Giuliano
Di Matteo, Gerardo
Mastropierro, Rosa
Nardi, Matilde
Cervi, Edoardo
De Cicco, Giuseppe
Chiari, Ermanna
Curnis, Antonio
Bonardelli, Stefano
Coletti, Giuseppe
Manzato, Aldo
Metra, Marco
Ettori, Federica - Abstract:
- Abstract : Objective: To compare different vascular approaches on clinical outcome of patients undergoing transcatheter aortic valve implantation (TAVI) with self-expandable bioprosthesis. Methods: We included all the patients undergoing CoreValve implantation at our institute between September 2007 and March 2014. They were divided into four groups based on the vascular approach: percutaneous transfemoral (pTF), cut-down transfemoral (cTF), transaxillary (TAx) and transaortic (TAo). Clinical outcomes were evaluated according to Valve Academic Research Consortium-2 recommendations. Results: Out of 322 consecutive patients, 170 (53%) underwent pTF, 76 (23%) cTF, 32 (10%) TAx and 44 (14%) TAo approach. Although the TAx and TAo patients had a higher risk profile, they had a similar outcome compared with the pTF and cTF groups; in particular, there were no differences regarding cardiovascular and all-cause mortality at 30 days, 1 and 2 years, as well as stroke, myocardial infarction, bleeding, major vascular complications, permanent pacemaker implantation and acute kidney injury rates. The observed device success rate was higher in the TAo than in the other approaches (88.6 versus 65.9, 68.7 and 76.3% in the pTF, cTF and TAx groups, respectively; P = 0.019). No differences occurred regarding 30-day early safety and 1-year clinical efficacy across the four groups. Fluoroscopy time, amount of contrast medium used and minor vascular complications were significantly higher in pTFAbstract : Objective: To compare different vascular approaches on clinical outcome of patients undergoing transcatheter aortic valve implantation (TAVI) with self-expandable bioprosthesis. Methods: We included all the patients undergoing CoreValve implantation at our institute between September 2007 and March 2014. They were divided into four groups based on the vascular approach: percutaneous transfemoral (pTF), cut-down transfemoral (cTF), transaxillary (TAx) and transaortic (TAo). Clinical outcomes were evaluated according to Valve Academic Research Consortium-2 recommendations. Results: Out of 322 consecutive patients, 170 (53%) underwent pTF, 76 (23%) cTF, 32 (10%) TAx and 44 (14%) TAo approach. Although the TAx and TAo patients had a higher risk profile, they had a similar outcome compared with the pTF and cTF groups; in particular, there were no differences regarding cardiovascular and all-cause mortality at 30 days, 1 and 2 years, as well as stroke, myocardial infarction, bleeding, major vascular complications, permanent pacemaker implantation and acute kidney injury rates. The observed device success rate was higher in the TAo than in the other approaches (88.6 versus 65.9, 68.7 and 76.3% in the pTF, cTF and TAx groups, respectively; P = 0.019). No differences occurred regarding 30-day early safety and 1-year clinical efficacy across the four groups. Fluoroscopy time, amount of contrast medium used and minor vascular complications were significantly higher in pTF patients, as well as in-hospital stay in the TAo group. Atrial fibrillation and prosthetic valve regurgitation, but not the vascular approach, were independent predictors of all-cause mortality. Conclusion: A more invasive vascular approach, for CoreValve implantation, even in higher risk patients, does not affect early-term, mid-term and long-term outcomes. … (more)
- Is Part Of:
- Journal of cardiovascular medicine. Volume 16:Issue 4(2015:Apr.)
- Journal:
- Journal of cardiovascular medicine
- Issue:
- Volume 16:Issue 4(2015:Apr.)
- Issue Display:
- Volume 16, Issue 4 (2015)
- Year:
- 2015
- Volume:
- 16
- Issue:
- 4
- Issue Sort Value:
- 2015-0016-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-04
- Subjects:
- self-expandable bioprosthesis -- transcatheter aortic valve implantation -- vascular approach
Cardiology -- Periodicals
Cardiovascular system -- Diseases -- Periodicals
Cardiology -- Periodicals
Cardiovascular Diseases -- Periodicals
616.1005 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=01244665-000000000-00000 ↗
http://www.jcardiovascularmedicine.com/pt/re/jcm/home.htm ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.2459/JCM.0000000000000252 ↗
- Languages:
- English
- ISSNs:
- 1558-2027
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.867300
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5295.xml