Intraoperative Flow Measurement by Microflow Probe During Surgery for Brain Arteriovenous Malformations. Issue 2 (June 2015)
- Record Type:
- Journal Article
- Title:
- Intraoperative Flow Measurement by Microflow Probe During Surgery for Brain Arteriovenous Malformations. Issue 2 (June 2015)
- Main Title:
- Intraoperative Flow Measurement by Microflow Probe During Surgery for Brain Arteriovenous Malformations
- Authors:
- Della Puppa, Alessandro
Rustemi, Oriela
Scienza, Renato - Abstract:
- Abstract : BACKGROUND: Intraoperative quantitative flow measurement by a microvascular ultrasonic flow probe is an established methodology in aneurysm surgery. OBJECTIVE: To test the present flow measurement procedure in brain arteriovenous malformation (AVM) surgery. METHODS: Data from 25 patients with brain AVMs who consecutively underwent microsurgical resection with the assistance of flow measurement by a microflow probe were retrospectively analyzed. Flowmetry was performed on arterial feeders, potentially transit arteries, and venous drainage of AVM in different phases of resection. RESULTS: A quantitative flow measurement was performed 203 times on 92 vessels. Flowmetry was able to define the flow direction of AVM vessels in all cases, thereby discriminating between arterial feeders and venous drainages, both superficially and deeply located. During AVM dissection, flowmetry identified a transit artery in 12% of cases by detecting a flow drop between 2 points of the same vessel. At the final stage of resection, a residual nidus, potentially missed at surgical dissection, was detected when the flow value of venous drainage was greater than 4 mL/min (20% of patients). Pre-resection microflow probe measurements were concordant with indocyanine green videoangiography data on AVM angioarchitecture in all cases. No microflow probe–induced AVM vessel injury was reported. Complete AVM resection was achieved in all cases with a low morbidity (modified Rankin Scale score ⩽1).Abstract : BACKGROUND: Intraoperative quantitative flow measurement by a microvascular ultrasonic flow probe is an established methodology in aneurysm surgery. OBJECTIVE: To test the present flow measurement procedure in brain arteriovenous malformation (AVM) surgery. METHODS: Data from 25 patients with brain AVMs who consecutively underwent microsurgical resection with the assistance of flow measurement by a microflow probe were retrospectively analyzed. Flowmetry was performed on arterial feeders, potentially transit arteries, and venous drainage of AVM in different phases of resection. RESULTS: A quantitative flow measurement was performed 203 times on 92 vessels. Flowmetry was able to define the flow direction of AVM vessels in all cases, thereby discriminating between arterial feeders and venous drainages, both superficially and deeply located. During AVM dissection, flowmetry identified a transit artery in 12% of cases by detecting a flow drop between 2 points of the same vessel. At the final stage of resection, a residual nidus, potentially missed at surgical dissection, was detected when the flow value of venous drainage was greater than 4 mL/min (20% of patients). Pre-resection microflow probe measurements were concordant with indocyanine green videoangiography data on AVM angioarchitecture in all cases. No microflow probe–induced AVM vessel injury was reported. Complete AVM resection was achieved in all cases with a low morbidity (modified Rankin Scale score ⩽1). CONCLUSION: Multistage intraoperative quantitative flow measurement proved to be a feasible, safe, repeatable, and reliable methodology to assist surgery in different phases of AVM resection. Further studies are needed to assess the impact of this approach on AVM patient outcomes. ABBREVIATIONS: AVM, arteriovenous malformation bAVM, brain arteriovenous malformation DSA, digital subtraction angiography ICG-VA, indocyanine green videoangiography mRS, modified Rankin Scale SM, Spetzler Martin … (more)
- Is Part Of:
- Operative neurosurgery. Volume 11:Issue 2(2015)
- Journal:
- Operative neurosurgery
- Issue:
- Volume 11:Issue 2(2015)
- Issue Display:
- Volume 11, Issue 2 (2015)
- Year:
- 2015
- Volume:
- 11
- Issue:
- 2
- Issue Sort Value:
- 2015-0011-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-06
- Subjects:
- Brain arteriovenous malformation -- Microsurgery -- Cerebrovascular surgery -- Flow measurement -- Microflow probe -- Flowmetry
Nervous system -- Surgery -- Periodicals
617.480590 - Journal URLs:
- https://academic.oup.com/ons/issue ↗
http://journals.lww.com/onsonline/pages/default.aspx ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.1227/NEU.0000000000000741 ↗
- Languages:
- English
- ISSNs:
- 2332-4252
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6269.380200
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5285.xml