Creatinine in urine – a method comparison. Issue 10 (3rd March 2017)
- Record Type:
- Journal Article
- Title:
- Creatinine in urine – a method comparison. Issue 10 (3rd March 2017)
- Main Title:
- Creatinine in urine – a method comparison
- Authors:
- Luginbühl, Marc
Weinmann, Wolfgang - Abstract:
- Abstract : Drug screening in urine is widely applied in forensic toxicology. Contrary to blood analysis, excessive or reduced fluid intake can substantially alter the concentration of substances in urine. As a standard to detect urinary dilution, creatinine concentrations are analyzed. A sample with a concentration below 20 mg/dL is generally defined as too diluted to provide a valid result in abstinence control samples. This work investigates the potential of three different methods for the determination of creatinine concentrations in urine samples: A ZIC®‐HILIC‐based liquid chromatography–tandem mass spectrometry (LC–MS/MS) method, a spectrophotometric method on an AU 480 chemistry system, and a portable, chemical‐reaction‐based, point‐of‐care testing device were compared by measuring 200 urine samples. When comparing the two laboratory methods, LC–MS/MS and spectrophotometry, a mean difference of 3.7 ± 14 mg/dL was found, indicating that the spectrophotometric method slightly overestimates the creatinine concentration. When comparing the LC–MS/MS method with the point‐of‐care testing device, a mean concentration difference within the calibration range for POCT (>20 mg/dL (excluding 16 samples) and <500 mg/dL (excluding 4 samples)) of 21 ± 37 mg/dL was found, indicating that the point‐of‐care testing device overestimates the measured creatinine concentration. A point‐of‐care testing device as used during this study can provide valuable information for on‐site analysis.Abstract : Drug screening in urine is widely applied in forensic toxicology. Contrary to blood analysis, excessive or reduced fluid intake can substantially alter the concentration of substances in urine. As a standard to detect urinary dilution, creatinine concentrations are analyzed. A sample with a concentration below 20 mg/dL is generally defined as too diluted to provide a valid result in abstinence control samples. This work investigates the potential of three different methods for the determination of creatinine concentrations in urine samples: A ZIC®‐HILIC‐based liquid chromatography–tandem mass spectrometry (LC–MS/MS) method, a spectrophotometric method on an AU 480 chemistry system, and a portable, chemical‐reaction‐based, point‐of‐care testing device were compared by measuring 200 urine samples. When comparing the two laboratory methods, LC–MS/MS and spectrophotometry, a mean difference of 3.7 ± 14 mg/dL was found, indicating that the spectrophotometric method slightly overestimates the creatinine concentration. When comparing the LC–MS/MS method with the point‐of‐care testing device, a mean concentration difference within the calibration range for POCT (>20 mg/dL (excluding 16 samples) and <500 mg/dL (excluding 4 samples)) of 21 ± 37 mg/dL was found, indicating that the point‐of‐care testing device overestimates the measured creatinine concentration. A point‐of‐care testing device as used during this study can provide valuable information for on‐site analysis. However, reported concentrations above 500 mg/dL should be further evaluated, for example by dilution of the sample. Copyright © 2017 John Wiley & Sons, Ltd. Abstract : Three different methods for the determination of creatinine concentrations in urine are carefully investigated. LC–MS/MS proved to be advantageous compared to a spectrophotometric or point‐of‐care testing based analysis method. … (more)
- Is Part Of:
- Drug testing and analysis. Volume 9:Issue 10(2017)
- Journal:
- Drug testing and analysis
- Issue:
- Volume 9:Issue 10(2017)
- Issue Display:
- Volume 9, Issue 10 (2017)
- Year:
- 2017
- Volume:
- 9
- Issue:
- 10
- Issue Sort Value:
- 2017-0009-0010-0000
- Page Start:
- 1537
- Page End:
- 1541
- Publication Date:
- 2017-03-03
- Subjects:
- creatinine -- urine analysis -- drug testing -- point‐of‐care testing -- urine manipulation
Drugs -- Analysis -- Periodicals
Drug testing -- Periodicals
Chemistry, Forensic -- Periodicals
615.1901 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1942-7611 ↗
http://rzblx1.uni-regensburg.de/ezeit/warpto.phtml?colors=7&jour_id=110501 ↗
http://www3.interscience.wiley.com/journal/121408477/home ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/dta.2166 ↗
- Languages:
- English
- ISSNs:
- 1942-7603
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3629.424000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 5291.xml