Intraoperative Lung-Protective Ventilation Trends and Practice Patterns: A Report from the Multicenter Perioperative Outcomes Group. (November 2015)
- Record Type:
- Journal Article
- Title:
- Intraoperative Lung-Protective Ventilation Trends and Practice Patterns: A Report from the Multicenter Perioperative Outcomes Group. (November 2015)
- Main Title:
- Intraoperative Lung-Protective Ventilation Trends and Practice Patterns
- Authors:
- Bender, S. Patrick
Paganelli, William C.
Gerety, Lyle P.
Tharp, William G.
Shanks, Amy M.
Housey, Michelle
Blank, Randal S.
Colquhoun, Douglas A.
Fernandez-Bustamante, Ana
Jameson, Leslie C.
Kheterpal, Sachin - Abstract:
- Abstract : BACKGROUND: The use of an intraoperative lung-protective ventilation strategy through tidal volume (TV) size reduction and positive end-expiratory pressure (PEEP) has been increasingly investigated. In this article, we describe the current intraoperative lung-protective ventilation practice patterns and trends. METHODS: By using the Multicenter Perioperative Outcomes Group database, we identified all general endotracheal anesthetics from January 2008 through December 2013 at 10 institutions. The following data were calculated: (1) percentage of patients receiving TV > 10 mL/kg predicted body weight (PBW); (2) median initial and overall TV in mL/kg PBW and; (3) percentage of patients receiving PEEP ≥ 5 cm H2 O. The data were analyzed at 3-month intervals. Interinstitutional variability was assessed. RESULTS: A total of 330, 823 patients met our inclusion criteria for this study. During the study period, the percentage of patients receiving TV > 10 mL/kg PBW was reduced for all patients (26% to 14%) and in the subpopulations of obese (41% to 25%), short stature (52% to 36%), and females (39% to 24%; all P values <0.001). There was a significant reduction in TV size (8.90–8.20 mL/kg PBW, P < 0.001). There was also a statistically significant but clinically irrelevant difference between initial and overall TV size (8.65 vs 8.63 mL/kg PBW, P < 0.001). Use of PEEP ≥ 5 cm H2 O increased during the study period (25%–45%, P < 0.001). TV usage showed significantAbstract : BACKGROUND: The use of an intraoperative lung-protective ventilation strategy through tidal volume (TV) size reduction and positive end-expiratory pressure (PEEP) has been increasingly investigated. In this article, we describe the current intraoperative lung-protective ventilation practice patterns and trends. METHODS: By using the Multicenter Perioperative Outcomes Group database, we identified all general endotracheal anesthetics from January 2008 through December 2013 at 10 institutions. The following data were calculated: (1) percentage of patients receiving TV > 10 mL/kg predicted body weight (PBW); (2) median initial and overall TV in mL/kg PBW and; (3) percentage of patients receiving PEEP ≥ 5 cm H2 O. The data were analyzed at 3-month intervals. Interinstitutional variability was assessed. RESULTS: A total of 330, 823 patients met our inclusion criteria for this study. During the study period, the percentage of patients receiving TV > 10 mL/kg PBW was reduced for all patients (26% to 14%) and in the subpopulations of obese (41% to 25%), short stature (52% to 36%), and females (39% to 24%; all P values <0.001). There was a significant reduction in TV size (8.90–8.20 mL/kg PBW, P < 0.001). There was also a statistically significant but clinically irrelevant difference between initial and overall TV size (8.65 vs 8.63 mL/kg PBW, P < 0.001). Use of PEEP ≥ 5 cm H2 O increased during the study period (25%–45%, P < 0.001). TV usage showed significant interinstitutional variability ( P < 0.001). CONCLUSIONS: Although decreasing, a significant percentage of patients are ventilated with TV > 10 mL/kg PBW, especially if they are female, obese, or of short stature. The use of PEEP ≥ 5 cm H2 O has increased significantly. Creating awareness of contemporary practice patterns and demonstrating the efficacy of lung-protective ventilation are still needed to optimize intraoperative ventilation. Abstract : Published ahead of print September 1, 2015 … (more)
- Is Part Of:
- Anesthesia & analgesia. Volume 121:Number 5(2015)
- Journal:
- Anesthesia & analgesia
- Issue:
- Volume 121:Number 5(2015)
- Issue Display:
- Volume 121, Issue 5 (2015)
- Year:
- 2015
- Volume:
- 121
- Issue:
- 5
- Issue Sort Value:
- 2015-0121-0005-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-11
- Subjects:
- Anesthesiology -- Periodicals
Anesthesia
Anesthesiology
Analgesia
Analgesics
Anesthesiology -- Periodicals
617.9605 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00000539-000000000-00000 ↗
http://journals.lww.com/anesthesia-analgesia/Pages/default.aspx ↗
http://www.anesthesia-analgesia.org ↗
http://journals.lww.com ↗ - DOI:
- 10.1213/ANE.0000000000000940 ↗
- Languages:
- English
- ISSNs:
- 0003-2999
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0900.500000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 5268.xml