Markov chain Monte Carlo analysis for the selection of a cell‐killing model under high‐dose‐rate irradiation. Issue 10 (15th September 2017)
- Record Type:
- Journal Article
- Title:
- Markov chain Monte Carlo analysis for the selection of a cell‐killing model under high‐dose‐rate irradiation. Issue 10 (15th September 2017)
- Main Title:
- Markov chain Monte Carlo analysis for the selection of a cell‐killing model under high‐dose‐rate irradiation
- Authors:
- Matsuya, Yusuke
Kimura, Takaaki
Date, Hiroyuki - Abstract:
- Abstract : Purpose: High‐dose‐rate irradiation with 6 MV linac x rays is a wide‐spread means to treat cancer tissue in radiotherapy. The treatment planning relies on a mathematical description of surviving fraction (SF), such as the linear‐quadratic model (LQM) formula. However, even in the case of high‐dose‐rate treatment, the repair kinetics of DNA damage during dose‐delivery time plays a function in predicting the dose‐SF relation. This may call the SF model selection into question when considering the dose‐delivery time or dose‐rate effects (DREs) in radiotherapy and in vitro cell experiments. In this study, we demonstrate the importance of dose‐delivery time at high‐dose‐rate irradiations used in radiotherapy by means of Bayesian estimation. Methods: To evaluate the model selection for SF, three types of models, the LQM and two microdosimetric‐kinetic models with and without DREs (MKMDR and MKM) were applied to describe in vitro SF data (our work and references). The parameters in each model were evaluated by a Markov chain Monte Carlo (MCMC) simulation. Results: The MCMC analysis shows that the cell survival curve by the MKMDR fits the experimental data the best in terms of the deviance information criterion (DIC). In the fractionated regimen with 30 fractions to a total dose of 60 Gy, the final cell survival estimated by the MKMDR was higher than that by the LQM. This suggests that additional fractions are required for attaining the total dose equivalent to yield theAbstract : Purpose: High‐dose‐rate irradiation with 6 MV linac x rays is a wide‐spread means to treat cancer tissue in radiotherapy. The treatment planning relies on a mathematical description of surviving fraction (SF), such as the linear‐quadratic model (LQM) formula. However, even in the case of high‐dose‐rate treatment, the repair kinetics of DNA damage during dose‐delivery time plays a function in predicting the dose‐SF relation. This may call the SF model selection into question when considering the dose‐delivery time or dose‐rate effects (DREs) in radiotherapy and in vitro cell experiments. In this study, we demonstrate the importance of dose‐delivery time at high‐dose‐rate irradiations used in radiotherapy by means of Bayesian estimation. Methods: To evaluate the model selection for SF, three types of models, the LQM and two microdosimetric‐kinetic models with and without DREs (MKMDR and MKM) were applied to describe in vitro SF data (our work and references). The parameters in each model were evaluated by a Markov chain Monte Carlo (MCMC) simulation. Results: The MCMC analysis shows that the cell survival curve by the MKMDR fits the experimental data the best in terms of the deviance information criterion (DIC). In the fractionated regimen with 30 fractions to a total dose of 60 Gy, the final cell survival estimated by the MKMDR was higher than that by the LQM. This suggests that additional fractions are required for attaining the total dose equivalent to yield the same effect as the conventional regimen using the LQM in fractionated radiotherapy. Conclusions: Damage repair during dose‐delivery time plays a key role in precisely estimating cell survival even at a high dose rate in radiotherapy. Consequently, it was suggested that the cell‐killing model without repair factor during a short dose‐delivery time may overestimate actual cell killing in fractionated radiotherapy. … (more)
- Is Part Of:
- Medical physics. Volume 44:Issue 10(2017)
- Journal:
- Medical physics
- Issue:
- Volume 44:Issue 10(2017)
- Issue Display:
- Volume 44, Issue 10 (2017)
- Year:
- 2017
- Volume:
- 44
- Issue:
- 10
- Issue Sort Value:
- 2017-0044-0010-0000
- Page Start:
- 5522
- Page End:
- 5532
- Publication Date:
- 2017-09-15
- Subjects:
- dose‐delivery time -- fractionated irradiation -- linear‐quadratic model -- Markov chain Monte Carlo simulation -- microdosimetric‐kinetic model
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.12508 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5263.xml