Challenges in MR‐only seed localization for postimplant dosimetry in permanent prostate brachytherapy. Issue 10 (11th September 2017)
- Record Type:
- Journal Article
- Title:
- Challenges in MR‐only seed localization for postimplant dosimetry in permanent prostate brachytherapy. Issue 10 (11th September 2017)
- Main Title:
- Challenges in MR‐only seed localization for postimplant dosimetry in permanent prostate brachytherapy
- Authors:
- Zijlstra, Frank
Moerland, Marinus A.
van der Voort van Zyp, Jochem R.N.
Noteboom, Juus L.
Viergever, Max A.
Seevinck, Peter R. - Abstract:
- Abstract : Purpose: An MR‐only postimplant dosimetry workflow for low dose rate (LDR) brachytherapy could reduce patient burden, improve accuracy, and improve cost efficiency. However, localization of brachytherapy seeds on MRI scans remains a major challenge for this type of workflow. In this study, we propose and validate an MR‐only seed localization method and identify remaining challenges. Methods and materials: The localization method was based on template matching of simulations of complex‐valued imaging artifacts around metal brachytherapy seeds. The method was applied to MRI scans of 25 prostate cancer patients who underwent LDR brachytherapy and for whom postimplant dosimetry was performed after 4 weeks. The seed locations found with the MR‐only method were validated against the seed locations found on CT. The circumstances in which detection errors were made were classified to gain an insight in the nature of the errors. Results: A total of 1490 of 1557 (96%) seeds were correctly detected, while 67 false‐positive errors were made. The correctly detected seed locations had a high spatial accuracy with an average error of 0.8 mm compared with CT. A majority of the false positives occurred near other seeds. Most false negatives were found in either stranded configurations without spacers or near other seeds. Conclusions: The low detection error rate and high localization accuracy obtained by the complex‐valued template matching approach are promising for futureAbstract : Purpose: An MR‐only postimplant dosimetry workflow for low dose rate (LDR) brachytherapy could reduce patient burden, improve accuracy, and improve cost efficiency. However, localization of brachytherapy seeds on MRI scans remains a major challenge for this type of workflow. In this study, we propose and validate an MR‐only seed localization method and identify remaining challenges. Methods and materials: The localization method was based on template matching of simulations of complex‐valued imaging artifacts around metal brachytherapy seeds. The method was applied to MRI scans of 25 prostate cancer patients who underwent LDR brachytherapy and for whom postimplant dosimetry was performed after 4 weeks. The seed locations found with the MR‐only method were validated against the seed locations found on CT. The circumstances in which detection errors were made were classified to gain an insight in the nature of the errors. Results: A total of 1490 of 1557 (96%) seeds were correctly detected, while 67 false‐positive errors were made. The correctly detected seed locations had a high spatial accuracy with an average error of 0.8 mm compared with CT. A majority of the false positives occurred near other seeds. Most false negatives were found in either stranded configurations without spacers or near other seeds. Conclusions: The low detection error rate and high localization accuracy obtained by the complex‐valued template matching approach are promising for future clinical application of MR‐only dosimetry. The most important remaining challenge is robustness with regard to configurations of multiple seeds in close vicinity, such as in strands of seeds without spacers. This issue could potentially be resolved by simulating specific configurations of multiple seeds or by constraining the treatment planning to avoid these configurations, which could make the proposed method competitive with CT‐based seed localization. … (more)
- Is Part Of:
- Medical physics. Volume 44:Issue 10(2017)
- Journal:
- Medical physics
- Issue:
- Volume 44:Issue 10(2017)
- Issue Display:
- Volume 44, Issue 10 (2017)
- Year:
- 2017
- Volume:
- 44
- Issue:
- 10
- Issue Sort Value:
- 2017-0044-0010-0000
- Page Start:
- 5051
- Page End:
- 5060
- Publication Date:
- 2017-09-11
- Subjects:
- brachytherapy -- MRI -- seed localization -- simulation -- susceptibility -- template matching
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.12505 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5263.xml