Diffusion-Weighted Magnetic Resonance Imaging in Distinguishing Between Mucin-Producing and Serous Pancreatic Cysts. Issue 4 (July 2016)
- Record Type:
- Journal Article
- Title:
- Diffusion-Weighted Magnetic Resonance Imaging in Distinguishing Between Mucin-Producing and Serous Pancreatic Cysts. Issue 4 (July 2016)
- Main Title:
- Diffusion-Weighted Magnetic Resonance Imaging in Distinguishing Between Mucin-Producing and Serous Pancreatic Cysts
- Authors:
- Pozzessere, Chiara
Castaños Gutiérrez, Sandra Luz
Corona-Villalobos, Celia Pamela
Righi, Lorenzo
Xu, Chunmiao
Lennon, Anne Marie
Wolfgang, Christopher L.
Hruban, Ralph H.
Goggins, Michael
Canto, Marcia I.
Kamel, Ihab R. - Abstract:
- Abstract : Objective: The aim of this study was to evaluate the feasibility and reproducibility of diffusion-weighted imaging in distinguishing between mucin-producing and serous pancreatic cysts. Methods: Forty-four pancreatic cysts (43 patients, 27 women; mean age, 57 years; 26 mucin-producing cysts, 18 serous cysts) that underwent histological examination or cyst analysis after diffusion-weighted magnetic resonance imaging were retrospectively reviewed. Three blinded readers independently evaluated signal intensity and apparent diffusion coefficient (ADC). Intraobserver and interobserver agreements were calculated. Fisher exact test and Welch t test were used to compare signal intensity and ADC values, respectively, with pathological results. Receiver operating characteristic analysis was used to determine diagnostic accuracy of various thresholds for ADC. A P value less than 0.05 was considered statistically significant. Results: Mean ADC values of the mucin-producing cysts were 3.26 × 10 −3, 3.27 × 10 −3, and 3.35 × 10 −3 mm 2 /s for the 3 readers, respectively. Mean ADC values of the serous cysts were 2.86 × 10 −3, 2.85 × 10 −3, and 2.85 × 10 −3 mm 2 /s for the 3 readers, respectively. Differences in ADC values between the 2 cyst groups were 12.4%, 12.9%, and 14.8% for the 3 readers, respectively ( P < 0.001). Intraobserver and interobserver agreement was excellent. A threshold ADC of 3 × 10 −3 mm 2 /s resulted in correct identification of cysts in 77% to 81% of cases,Abstract : Objective: The aim of this study was to evaluate the feasibility and reproducibility of diffusion-weighted imaging in distinguishing between mucin-producing and serous pancreatic cysts. Methods: Forty-four pancreatic cysts (43 patients, 27 women; mean age, 57 years; 26 mucin-producing cysts, 18 serous cysts) that underwent histological examination or cyst analysis after diffusion-weighted magnetic resonance imaging were retrospectively reviewed. Three blinded readers independently evaluated signal intensity and apparent diffusion coefficient (ADC). Intraobserver and interobserver agreements were calculated. Fisher exact test and Welch t test were used to compare signal intensity and ADC values, respectively, with pathological results. Receiver operating characteristic analysis was used to determine diagnostic accuracy of various thresholds for ADC. A P value less than 0.05 was considered statistically significant. Results: Mean ADC values of the mucin-producing cysts were 3.26 × 10 −3, 3.27 × 10 −3, and 3.35 × 10 −3 mm 2 /s for the 3 readers, respectively. Mean ADC values of the serous cysts were 2.86 × 10 −3, 2.85 × 10 −3, and 2.85 × 10 −3 mm 2 /s for the 3 readers, respectively. Differences in ADC values between the 2 cyst groups were 12.4%, 12.9%, and 14.8% for the 3 readers, respectively ( P < 0.001). Intraobserver and interobserver agreement was excellent. A threshold ADC of 3 × 10 −3 mm 2 /s resulted in correct identification of cysts in 77% to 81% of cases, with sensitivity and specificity ranging between 84% and 88% and 66% and 72%, respectively. Conclusions: Diffusion-weighted imaging may be a helpful tool in distinguishing between mucin-producing and serous pancreatic cysts. … (more)
- Is Part Of:
- Journal of computer assisted tomography. Volume 40:Issue 4(2016)
- Journal:
- Journal of computer assisted tomography
- Issue:
- Volume 40:Issue 4(2016)
- Issue Display:
- Volume 40, Issue 4 (2016)
- Year:
- 2016
- Volume:
- 40
- Issue:
- 4
- Issue Sort Value:
- 2016-0040-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-07
- Subjects:
- diffusion-weighted MRI -- pancreatic cyst -- intraductal papillary mucinous neoplasms -- mucinous cystic neoplasms -- serous cystadenomas
Tomography -- Periodicals
Tomography -- Periodicals
Tomography
Periodicals
616.0757 - Journal URLs:
- http://journals.lww.com/jcat/pages/default.aspx ↗
http://ovidsp.tx.ovid.com ↗
http://www.jcat.org ↗
http://www.rad.bqsm.edu/jcat ↗
http://journals.lww.com ↗
http://www.lww.com/Product/0363-8715 ↗ - DOI:
- 10.1097/RCT.0000000000000403 ↗
- Languages:
- English
- ISSNs:
- 0363-8715
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4963.650000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 5262.xml